Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Front end of the line

For many operations, workers are assigned to assist in conducting decontamination of workers wearing Level A or B PPE during the decontamination process. Decontamination workers stationed at the front end of the decontamination line may require more protection from chemical and radiological contaminants than decontamination workers assigned to the latter stages of decontamination. [Pg.159]

Draw a line from the back-foot (FBM) of the movable component or MTBM through the front-foot of the movable component toward the vertical line where the stationary coupling is located. Draw a short vertical line at the coupling end of the line. Finish the... [Pg.931]

Benjamin Franklin was a great inventor and diplomat, as well as one of America s founding fathers. He was also a very curious person, which made him an excellent scientist. In 1757, when he was on a ship in a fleet traveling to America from England, he noticed that the ships at the end of the line had smoother sailing than those in front. [Pg.68]

Today s CMP applications concern both front-end steps such as shallow trench isolation (STI) and inter metal dielectric (IMD) in the back end of the line. [Pg.184]

A schematic diagram of the front end of the beam line is shown in figure 4.8. The machine vacuum has to be protected. Hence, the beam lines emanating from the ring are separated from the main ring vacuum chamber. For an X-ray beam line this is by using a beryllium window at the front end of the beam line. For a soft X-ray or vacuum ultra-violet (VUV) line such a window would completely absorb the radiation of... [Pg.103]

Another development in HPLC analysis is the interfacing of on-line sample clean-up technologies at the front end of the HPLC analytical column. Using a switching valve, complex samples can be injected directly onto a sample preparation column, the stationary phase of which is designed to bind the analyte(s) of interest to the exclusion of the rest of the matrix, which runs to waste. Then the valve is switched and the mobile phase flows through the sample preparation column where it picks up the analyte(s) and carries them onto the analytical column and through to the detector in the normal way. This automation of sample preparation saves time and effort and reduces errors. There are many applications of HPLC assays in conjunction with on-line sample clean-up methods in the literature ... [Pg.87]

The press ram is fitted to the front end of the piston rod and can be rotated around the centre line or arranged in a fixed position. The press ram must be easily replaceable, as it is subject to wear and tear. It is made either of metal or plastic and may be of a convex or concave shape as the case may be. The position of the press ram is always displayed at the control panel. [Pg.295]

Naturally, in three-phase designs there are many possibilities for variations with the fitting of special baffles, chambers and channels into the front end of the bowl but the principle is the same. However the use of a skimmer (see Section 2.4.3) in three-phase designs is very useful in controlling the equilibrium line between the two liquid phases while the bow l is at speed. The casing design is, of course, different. [Pg.87]

The physical model of the pressurized cooldown process proposed from the above observations is as follows When the line inlet valve is opened, a liquid front quickly advances into the line. This front initially overshoots its equilibrium" position, and pressure surges result. The front then proceeds in a relatively uniform manner down the line at a rate that is primarily controlled by the ability of the line to vent the cooldown gas. The arrival of single-phase liquid at the end of the line corresponds closely with the attainment of equilibrium wall temperature. This physical model will serve as a guide in the development of an analytical solution of line cooldown time. [Pg.384]

The first few turns of the line end coil of a motor or transformer and short lengths of interconnecting cables and overhead lines and their associated terminal equipment, will thus be subject to severe stresses and will be rendered vulnerable to damage by such sleep-fronted transient voltages. [Pg.573]

FIGURE 2.1 A side view of the structure of the prototype G-protein-coupled, 7TM receptor rhodopsin. The x-ray structure of bovine rhodopsin is shown with horizontal gray lines, indicating the limits of the cellular lipid membrane. The retinal ligand is shown in a space-filling model as the cloud in the middle of the structure. The seven transmembrane (7TM) helices are shown in solid ribbon form. Note that TM-III is rather tilted (see TM-III at the extracellular and intracellular end of the helix) and that kinks are present in several of the other helices, such as TM-V (to the left), TM-VI (in front of the retinal), and TM-VII. In all of these cases, these kinks are due to the presence of a well-conserved proline residue, which creates a weak point in the helical structure. These kinks are believed to be of functional importance in the activation mechanism for 7TM receptors in general. Also note the amphipathic helix-VIII which is located parallel to the membrane at the membrane interface. [Pg.85]

Examine the instrument to which you are assigned. Locate the source of the carrier gas and trace the line to the instrument. If an FID is to be used, also locate the source of the hydrogen and air, and trace the lines of each to the instrument. Locate the injection port. Note any gauges and controls on the front of the instrument, and try to identify their functions. Open the column oven and locate the column. Note the proximity of the inlet end of the column to the injection port. Note the outlet end of the column and locate the detector. [Pg.358]

External resources may he needed if the incident investigation work exceeds site capahilities. These resources could include corporate personnel or experts from outside the company. (The team leader may also he external if the incident is major since the leader s independence sets the tone for the investigation.) Company business unit leaders should confer with the team leader to determine whether external assistance is recommended. Factors to consider include significant offsite consequences such as environmental impact or product quality concerns. A team of trained specialists should formally investigate any process incident that could significantly affect the business. At the lower end of the scale, if a near miss or minor incident occurs that has no potential for significant consequences, local supervision or front-line personnel normally may perform the investigation without outside assistance. [Pg.106]

The induction time data and density profiles pf detonations in oxy-hydrogen and oxy-methane mixtures were analyzed on the basis of the kinetic data obtained by the reflected-wave technique and similar methods. A plot of the ignition delay vs 1/T in oxy-ammonia mixtures gave a straight line with a slope corresponding to an activation energy of 42.5 kcal/mole. In these mixtures the induction zone is not uniform, but the shock front is flat and end of the reaction zone is clearly discernible. Onedimensional detonation waves of low Mach number but relatively stable were obtained in a gas preheated to 600-1800°K ahead of the shock front... [Pg.505]


See other pages where Front end of the line is mentioned: [Pg.368]    [Pg.41]    [Pg.469]    [Pg.651]    [Pg.2]    [Pg.368]    [Pg.41]    [Pg.469]    [Pg.651]    [Pg.2]    [Pg.69]    [Pg.122]    [Pg.618]    [Pg.449]    [Pg.100]    [Pg.127]    [Pg.571]    [Pg.576]    [Pg.453]    [Pg.525]    [Pg.263]    [Pg.19]    [Pg.374]    [Pg.567]    [Pg.218]    [Pg.339]    [Pg.1045]    [Pg.90]    [Pg.124]    [Pg.190]    [Pg.316]    [Pg.207]    [Pg.373]    [Pg.725]    [Pg.125]    [Pg.363]    [Pg.187]    [Pg.25]    [Pg.274]    [Pg.641]    [Pg.93]   
See also in sourсe #XX -- [ Pg.41 , Pg.346 , Pg.436 , Pg.444 , Pg.449 , Pg.651 , Pg.675 ]




SEARCH



Front end

© 2024 chempedia.info