Conventional analytical techniques generally operate at the part per million or higher levels. Some techniques such as laser photo acoustic spectroscopy are capable of measuring phenomena at the 10-8-10-6 mol/L level. The most sensitive conventional analytical techniques, time-resolved laser-induced fluorescence, and ICP-MS are capable of measuring concentrations at the part per trillion level, that is, 1 part in 1012, but rarely does one see detection sensitivities at the single atom level as routinely found in some radioanalytical techniques. While techniques such as ICP-MS are replacing the use of neutron activation analysis in the routine measurement of part per billion concentrations, there can be no doubt about the unique sensitivity associated with radioanalytical methods. [Pg.581]

Transient terahertz spectroscopy Time-resolved terahertz (THz) spectroscopy (TRTS) has been used to measure the transient photoconductivity of injected electrons in dye-sensitised titanium oxide with subpicosecond time resolution (Beard et al, 2002 Turner et al, 2002). Terahertz probes cover the far-infrared (10-600 cm or 0.3-20 THz) region of the spectrum and measure frequency-dependent photoconductivity. The sample is excited by an ultrafast optical pulse to initiate electron injection and subsequently probed with a THz pulse. In many THz detection schemes, the time-dependent electric field 6 f) of the THz probe pulse is measured by free-space electro-optic sampling (Beard et al, 2002). Both the amplitude and the phase of the electric field can be determined, from which the complex conductivity of the injected electrons can be obtained. Fitting the complex conductivity allows the determination of carrier concentration and mobility. The time evolution of these quantities can be determined by varying the delay time between the optical pump and THz probe pulses. The advantage of this technique is that it provides detailed information on the dynamics of the injected electrons in the semiconductor and complements the time-resolved fluorescence and transient absorption techniques, which often focus on the dynamics of the adsorbates. A similar technique, time-resolved microwave conductivity, has been used to study injection kinetics in dye-sensitised nanocrystalline thin films (Fessenden and Kamat, 1995). However, its time resolution is limited to longer than 1 ns. [Pg.643]

Time-resolved techniques (time-resolved fluoroimmunoassay (TRFIA)) make use of the fact that some compounds have long decay times resulting in phosphorescence or delayed fluorescence (e.g., lanthanide chelate complexes) (Figure 1). Apparatus for time-resolved measurements use normally a pulsed excitation source and electronically gated detectors. By this way background fluorescence can be eliminated. [Pg.2178]

In this chapter, we will focus on the discussion of experiments that directly monitor the time-evolution of the electronic excited-state dynamics. In particular, we shall consider transient transmittance, time-resolved fluorescence, and time-resolved ionization spectroscopy. This is because these techniques have the potential to directly observe the ultrafast photochemical excited-state processes triggered by conical intersections. [Pg.744]

C-H Liu, BB Das, WL Sha Glassmann, GC Tang, KM Yoo, HR Zhu, L Akind, SS Lubicz, J Cleary, R Prudente, E Celmer, A Caron, RR Alfano. Raman, fluorescence and time-resolved light scattering as optical diagnostic techniques to separate diseased and normal biomedical media. J Photochem Photobiol B 16 187-209, 1992. [Pg.585]

The detection limit of fluorescence techniques is strongly dependent on the efflciency of the fluorescence equipment. The type of information provided by these techniques depends on the fluorescence mode used - either steady-state (steady-state fluorescence) or time-resolved (time-resolved fluorescence) - and also whether the excitation is performed with natural or polarized light (steady-state or time-resolved fluorescence anisotropy) [3],... [Pg.257]

Steady-state Fluorescence versus Time-resolved Fluorescence Techniques... [Pg.264]

For fluorescence measurements, by far the most versatile and widely used time-resolved emission technique involves time-correlated single-photon counting [8] in conjunction with mode-locked lasers, a typical mo m apparatus being shown in Figure 15.8. The instrument response time of such an apparatus with microchannel plate detectors is of the order of 70 ps, giving an ultimate capability of measurement of decay times in the region of 7 ps. However, it is the phenomenal sensitivity and accuracy which are the main attractive features of the technique, which is widely used for time-resolved fluorescence decay, time-resolved emission spectra, and time-resolved anisotropy measurements. Below ate described three applkations of such time-resolved measurements on synthetic polymers, derived from recent work by the author s group. [Pg.377]

Ghiggino, K. P., Roberts, A. J. and Phillips, D. Time-Resolved Fluorescence Techniques in Polymer and Biopolymer Studies. Vol. 40, pp. 69— 167. [Pg.153]

Homogeneous Time Resolved Fluorescence (HTRF) (Cisbio International) is an assay based on the proximity of a lanthanide cryptate donor and a fluorescent acceptor molecule whose excitation wavelength overlaps that of the cryptate s emission. The utility of this technique is based on the time resolved fluorescence properties of lanthanides. Lanthanides are unique in the increased lifetime of their fluorescence decay relative to other atoms, so a delay in collection of the emission intensity removes the background from other fluorescent molecules. An example of the HTRF assay is a generic protein-protein interaction assay shown in Fig. 2. [Pg.39]

Kazarian et al. [281-283] have used various spectroscopic techniques (including FUR, time-resolved ATR-FHR, Raman, UV/VIS and fluorescence spectroscopy) to characterise polymers processed with scC02. FTIR and ATR-FTIR spectroscopy have played an important role in developing the understanding and in situ monitoring of many SCF processes, such as drying, extraction and impregnation of polymeric materials. [Pg.85]

Another powerful tool for examining this issue is the use of time-resolved fluorescence spectra, especially when combined with the technique of Time-Resolved Area Normalized Emission Spectra (TRANES) developed by Periasamy and coworkers [78-80]. In this method, separate decay curves are collected over a wide range of emission wavelengths and reconstructed into time-resolved spectra, which are then normalized to constant area. In this model-free approach, it is possible to deduce the nature of heterogeneity of the fluorescent species from the... [Pg.323]

Product and services of interest include genomics, proteomics, custom research and services, and instruments, accessories, consumables and software. PerkinElmer proprietary technologies include time-resolved fluorescence which is employed in the sensitive Wallac DELFIA system and Wallac LANCE homogeneous assay system, and fluorescence polarization, [FP]2 , a robust fluorescence-based technique for receptor binding assays that is both fast and easy-to-use. [Pg.274]

All analytical methods that use some part of the electromagnetic spectrum have evolved into many highly specialized ways of extracting information. The interaction of X-rays with matter represents an excellent example of this diversity. In addition to straightforward X-ray absorption, diffraction, and fluorescence, there is a whole host of other techniques that are either directly X-ray-related or come about as a secondary result of X-ray interaction with matter, such as X-ray photoemission spectroscopy (XPS), surface-extended X-ray absorption fine structure (SEXAFS) spectroscopy, Auger electron spectroscopy (AES), and time-resolved X-ray diffraction techniques, to name only a few [1,2]. [Pg.292]

Knowledge of the dynamics of excited states is of major importance in understanding photophysical, photochemical and photobiological processes. Two time-resolved techniques, pulse fluorometry and phase-modulation fluorometry, are commonly used to recover the lifetimes, or more generally the parameters characterizing the S-pulse response of a fluorescent sample (i.e. the response to an infinitely short pulse of light expressed as the Dirac function S). [Pg.167]

The principle of the determination of time-resolved fluorescence spectra is described in Section 6.2.8. For solvent relaxation in the nanosecond time range, the single-photon timing technique can be used. The first investigation using this technique was reported by Ware and coworkers (1971). Figure 7.3 shows the reconstructed spectra of 4-aminophthalimide (4-AP) at various times after excitation. [Pg.207]


See other pages where Time-resolved fluorescence techniques is mentioned: [Pg.67]    [Pg.196]    [Pg.457]    [Pg.201]    [Pg.201]    [Pg.48]    [Pg.770]    [Pg.273]    [Pg.450]    [Pg.2948]    [Pg.61]    [Pg.67]    [Pg.176]    [Pg.43]    [Pg.87]    [Pg.200]    [Pg.357]    [Pg.927]    [Pg.476]    [Pg.485]    [Pg.151]    [Pg.148]    [Pg.168]    [Pg.176]    [Pg.169]    [Pg.125]    [Pg.280]   
See also in sourсe #XX -- [ Pg.1098 ]




SEARCH



Fluorescence techniques

Fluorescent technique

Fluorescent technique picosecond time-resolved

Resolvent technique

Studies of Photoinduced NH Tautomerism by Stationary and Time-Resolved Fluorescence Techniques

Time-resolved fluorescence

Time-resolved fluorescence depolarization technique

Time-resolved techniques

© 2024 chempedia.info