Feedback, electrochemical

Selzer Y and Manler D 2000 Scanning electrochemical microscopy. Theory of the feedback mode for hemispherical ultramicroelectrodes steady-state and transient behavior Anal. Chem. 72 2383... [Pg.1952]

Electrochemical Microsensors. The most successful chemical microsensor in use as of the mid-1990s is the oxygen sensor found in the exhaust system of almost all modem automobiles (see Exhaust control, automotive). It is an electrochemical sensor that uses a soHd electrolyte, often doped Zr02, as an oxygen ion conductor. The sensor exemplifies many of the properties considered desirable for all chemical microsensors. It works in a process-control situation and has very fast (- 100 ms) response time for feedback control. It is relatively inexpensive because it is designed specifically for one task and is mass-produced. It is relatively immune to other chemical species found in exhaust that could act as interferants. It performs in a very hostile environment and is reHable over a long period of time (36). [Pg.392]

Slow Strain-Rate Test In its present state of development, the results from slow strain-rate tests (SSRT) with electrochemical monitoring are not always completely definitive but, for a short-term test, they do provide considerable useful SCC information. Work in our laboratory shows that the SSRT with electrochemical monitoring and the U-bend tests are essentially equivalent in sensitivity in finding SCC. The SSRT is more versatile and faster, providing both mechanical and electrochemical feedback during testing. [Pg.2436]

As shown in Fig. 24, the mechanism of the instability is elucidated as follows At the portion where dissolution is accidentally accelerated and is accompanied by an increase in the concentration of dissolved metal ions, pit formation proceeds. If the specific adsorption is strong, the electric potential at the OHP of the recessed part decreases. Because of the local equilibrium of reaction, the fluctuation of the electrochemical potential must be kept at zero. As a result, the concentration component of the fluctuation must increase to compensate for the decrease in the potential component. This means that local dissolution is promoted more at the recessed portion. Thus these processes form a kind of positive feedback cycle. After several cycles, pits develop on the surface macroscopically through initial fluctuations. [Pg.257]

In pioneering studies [47], the SECM feedback mode was used to study the ET reaction between ferrocene (Fc), in nitrobenzene (NB), and the aqueous mediator, FcCOO, electrochemically generated at the UME by oxidation of the ferrocenemonocar-boxylate ion, FcCOO. Tetraethylammonium perchlorate (TEAP) was applied in both phases as the partitioning electrolyte. The results of this study indicated that the reaction at the ITIES was limited by the ET process, provided that there was a sufficiently high concentration of TEAP in both phases. [Pg.314]

The ITIES with an adsorbed monolayer of surfactant has been studied as a model system of the interface between microphases in a bicontinuous microemulsion [39]. This latter system has important applications in electrochemical synthesis and catalysis [88-92]. Quantitative measurements of the kinetics of electrochemical processes in microemulsions are difficult to perform directly, due to uncertainties in the area over which the organic and aqueous reactants contact. The SECM feedback mode allowed the rate of catalytic reduction of tra 5-l,2-dibromocyclohexane in benzonitrile by the Co(I) form of vitamin B12, generated electrochemically in an aqueous phase to be measured as a function of interfacial potential drop and adsorbed surfactants [39]. It was found that the reaction at the ITIES could not be interpreted as a simple second-order process. In the absence of surfactant at the ITIES the overall rate of the interfacial reaction was virtually independent of the potential drop across the interface and a similar rate constant was obtained when a cationic surfactant (didodecyldimethylammonium bromide) was adsorbed at the ITIES. In contrast a threefold decrease in the rate constant was observed when an anionic surfactant (dihexadecyl phosphate) was used. [Pg.321]

In scanning electrochemical microscopy (SECM) a microelectrode probe (tip) is used to examine solid-liquid and liquid-liquid interfaces. SECM can provide information about the chemical nature, reactivity, and topography of phase boundaries. The earlier SECM experiments employed microdisk metal electrodes as amperometric probes [29]. This limited the applicability of the SECM to studies of processes involving electroactive (i.e., either oxidizable or reducible) species. One can apply SECM to studies of processes involving electroinactive species by using potentiometric tips [36]. However, potentio-metric tips are suitable only for collection mode measurements, whereas the amperometric feedback mode has been used for most quantitative SECM applications. [Pg.397]

For in situ investigations of electrode surfaces, that is, for the study of electrodes in an electrochemical environment and under potential control, the metal tip inevitably also becomes immersed into the electrolyte, commonly an aqueous solution. As a consequence, electrochemical processes will occur at the tip/solution interface as well, giving rise to an electric current at the tip that is superimposed on the tunnel current and hence will cause the feedback circuit and therefore the imaging process to malfunction. The STM tip nolens volens becomes a fourth electrode in our system that needs to be potential controlled like our sample by a bipotentiostat. A schematic diagram of such an electric circuit, employed to combine electrochemical studies with electron tunneling between tip and sample, is provided in Figure 5.4. To reduce the electrochemical current at the tip/solution... [Pg.122]

In any imaging and spectroscopic mode of the STM, a bias is required between the sample and the tip. In an electrochemical solvent, faradaic current between the tip and sample can interfere with, and sometimes completely obscure, the tunneling current. This undesirable situation makes it very difficult to control the feedback and to maintain a constant tunneling gap between the tip and the sample. For example, in our laboratory, we have found that feedback control is lost on our present microscope if the faradaic current, ip, assumes a value greater than one-half that of the tunneling current, it. Use of partially insulated tips alleviates this condition, but unfortunately, does not completely eliminate the problem (57). [Pg.181]

Lithography With the STM Electrochemical Techniques. The nonuniform current density distribution generated by an STM tip has also been exploited for electrochemical surface modification schemes. These applications are treated in this paper as distinct from true in situ STM imaging because the electrochemical modification of a substrate does not a priori necessitate subsequent imaging with the STM. To date, all electrochemical modification experiments in which the tip has served as the counter electrode, the STM has been operated in a two-electrode mode, with the substrate surface acting as the working electrode. The tip-sample bias is typically adjusted to drive electrochemical reactions at both the sample surface and the STM tip. Because it has as yet been impossible to maintain feedback control of the z-piezo (tip-substrate distance) in the presence of significant faradaic current (vide infra), all electrochemical STM modification experiments to date have been performed in the absence of such feedback control. [Pg.191]

One must keep in mind that modern electrochemical instrumentation compensates for the potential drop i (Rn + Rnc) through the use of appropriate circuitry (positive feedback compensation). This adds a supplementary potential to the input potential of the potentiostat (equal to the ohmic drop of the potential), which is generated by taking a fraction of the faradaic current that passes through the electrochemical cell, such that in favourable cases there will be no error in the control of the potential. However, such circuitry can give rise to problems of reliability in the electrochemical response on occasions when an overcompensation is produced. [Pg.147]

Electrochemical progress has benefited tremendously from the application of feedback principles. It is essential for the modern electrochemist to be aware... [Pg.3]

As described in the introduction, submicrometer disk electrodes are extremely useful to probe local chemical events at the surface of a variety of substrates. However, when an electrode is placed close to a surface, the diffusion layer may extend from the microelectrode to the surface. Under these conditions, the equations developed for semi-infinite linear diffusion are no longer appropriate because the boundary conditions are no longer correct [97]. If the substrate is an insulator, the measured current will be lower than under conditions of semi-infinite linear diffusion, because the microelectrode and substrate both block free diffusion to the electrode. This phenomena is referred to as shielding. On the other hand, if the substrate is a conductor, the current will be enhanced if the couple examined is chemically stable. For example, a species that is reduced at the microelectrode can be oxidized at the conductor and then return to the microelectrode, a process referred to as feedback. This will occur even if the conductor is not electrically connected to a potentiostat, because the potential of the conductor will be the same as that of the solution. Both shielding and feedback are sensitive to the diameter of the insulating material surrounding the microelectrode surface, because this will affect the size and shape of the diffusion layer. When these concepts are taken into account, the use of scanning electrochemical microscopy can provide quantitative results. For example, with the use of a 30-nm conical electrode, diffusion coefficients have been measured inside a polymer film that is itself only 200 nm thick [98]. [Pg.398]

As a result of the effects of nonideal structures, second-order effects in parameters, and the numerous approximations made in the derivation of the current-voltage equations, (C.27) and (C.30) can only serve as a qualitative description of the actual device each individual design must be experimentally characterized. For these reasons it is advantageous to operate the FET in the constant drain current mode in which case a suitable feedback circuit supplies the gate voltage of the same magnitude but of the opposite polarity to that produced by the electrochemical part of the device. [Pg.364]

The specific electrochemical behaviour of IDAs is result of its design [97], i.e. two arrays intercalated and individually addressed in a bipotentiostatic system where reversible redox species can be cycled between one array (generator) and the other array (collector) (Fig. 32.3). The feedback obtained, greatly enhances the current and high sensitive detection can be achieved. An important application of IDAs is the electrochemical detection of p-aminophenol when it is generated from p-aminophenyl phosphate, by enzymatic reaction with alkaline phosphatase (like enzymatic label), in geno- [98-100] and immunoassays [101-103]. Another interesting feature of IDAs is the possibility of... [Pg.780]

A third screening method for arrays of electrocatalysts was recently introduced by Hillier and coworkers [15, 29, 30]. Using a scanning electrochemical microscope (SECM), a microelectrode tip is moved over an electrocatalyst array. The resulting electrochemical feedback currents are measured and used to generate an activity map of the electrocatalyst library. This method does not require individual electronic addressability for each electrocatalyst... [Pg.274]

Lee, Y., Z. Ding, A.J. Bard. 2002. Combined scanning electrochemical/optical microscopy with shear force and current feedback. Anal. Chem. 74 3634-3643. [Pg.181]

Alpuche-Aviles, M.A., and D.O. Wipf. 2001. Impedance feedback control for scanning electrochemical microscopy. Anal. Chem. 73 4873-4881. [Pg.181]

Scanning electrochemical microscopy (SECM the same abbreviation is also used for the device, i.e., the microscope) is often compared (and sometimes confused) with scanning tunneling microscopy (STM), which was pioneered by Binning and Rohrer in the early 1980s [1]. While both techniques make use of a mobile conductive microprobe, their principles and capabilities are totally different. The most widely used SECM probes are micrometer-sized ampero-metric ultramicroelectrodes (UMEs), which were introduced by Wightman and co-workers 1980 [2]. They are suitable for quantitative electrochemical experiments, and the well-developed theory is available for data analysis. Several groups employed small and mobile electrochemical probes to make measurements within the diffusion layer [3], to examine and modify electrode surfaces [4, 5], However, the SECM technique, as we know it, only became possible after the introduction of the feedback concept [6, 7],... [Pg.178]

The SECM can be used in the feedback mode to probe lateral mass-charge transfer [79-83]. The theory of SECM feedback surveyed in Section IV.A.2 assumes that the substrate surface is uniformly reactive. When lateral mass and/ or charge transfer occurs on the substrate surface, or within a thin film, the surface reactivity of the substrate becomes non-uniform and the SECM feedback theory must be modified. Unwin and Bard [79] developed the theory for adsorption-desorption of a redox species at the substrate that allowed for surface diffusion of the adsorbate. They introduced a new approach, the scanning electrochemical microscope induced desorption (SECMID), as a way to probe surface diffusion. The set of differential equations for the diffusion problem comprise Eqs. (8a,b), and Eq. (26), which relates the redox concentration at the substrate surface and the surface coverage by adsorbed species... [Pg.199]


See other pages where Feedback, electrochemical is mentioned: [Pg.294]    [Pg.1942]    [Pg.333]    [Pg.306]    [Pg.485]    [Pg.580]    [Pg.240]    [Pg.127]    [Pg.112]    [Pg.114]    [Pg.193]    [Pg.186]    [Pg.253]    [Pg.306]    [Pg.130]    [Pg.280]    [Pg.205]    [Pg.276]    [Pg.142]    [Pg.180]    [Pg.181]    [Pg.181]    [Pg.39]    [Pg.281]    [Pg.61]    [Pg.66]    [Pg.54]    [Pg.182]   
See also in sourсe #XX -- [ Pg.291 , Pg.293 ]