Spectroscopic mode

It is possible to obtain chemical information from STM when it is used in the spectroscopic mode, for example by measuring at a fixed distance the tunneling current / as a function of the voltage over the gap (I/V spectroscopy). This method of measurement is called scanning tunneling spectroscopy (STS) [49],... [Pg.206]

In any imaging and spectroscopic mode of the STM, a bias is required between the sample and the tip. In an electrochemical solvent, faradaic current between the tip and sample can interfere with, and sometimes completely obscure, the tunneling current. This undesirable situation makes it very difficult to control the feedback and to maintain a constant tunneling gap between the tip and the sample. For example, in our laboratory, we have found that feedback control is lost on our present microscope if the faradaic current, ip, assumes a value greater than one-half that of the tunneling current, it. Use of partially insulated tips alleviates this condition, but unfortunately, does not completely eliminate the problem (57). [Pg.181]

ISO Infrared Space Observatory, an ESA-led infrared space telescope that carried out targeted observations. ISO had both imaging and spectroscopic modes. [Pg.354]

MIPS Multi-band Imaging Photometer for Spitzer provides imaging capabilities in broad bands at 24, 70, and 160 am. In addition, the instrument has a low-resolution spectroscopic mode that operates between 55 and 95 pm. [Pg.356]

The second-order calibration example shown next is from the field of environmental analytical chemistry. A sensor was constructed to measure heavy metal ions in tap and lake water [Lin et al. 1994], The two heavy metal ions Pb2+ and Cd2+ are of special interest (the analytes) and there may be interferents from other metals, such as Co2+, Mn2+, Ni2+ and Zn2+. The principle of the sensor is described in detail in the original publication but repeated here briefly for illustration. The metal ions diffuse through a membrane and enter the sensor chamber upon which they form a colored complex with the metal indicator (4-(2-pyridylazo) resorcinol PAR) present in that chamber. Hence, the two modes (instrumental directions) of the sensor are the temporal mode related to the diffusion through the membrane, and the spectroscopic mode (visible spectroscopy from 380 to 700 nm). Selectivity in the temporal mode is obtained by differences in diffusion behavior of the metal ions (see Figure 10.22) and in the spectroscopic mode by spectral differences of the complexes formed. In the spectroscopic mode, second-derivative spectra are taken to enhance the selectivity (see Figure 10.23). The spectra were measured every 30 s with a resolution of 1 nm from 420 to 630 nm for a period of 37 min. This results in a data matrix of size 74 (times) x 210 (wavelengths) for each sample. [Pg.280]

It has been very fashionable to blame the kinetic behavior on chaos, which for our introductory purpose we can think of as the sensitivity to the precise initial conditions. If the initial conditions are fully and tightly specified (i.e., when one excites an eigenstate) then indeed the isolated system cannot forget. But in reality one can seldom excite a molecule to a fully specified initial state and if one did, then there would only be the spectroscopic mode of behavior. Otherwise, the point is that even quite simple mechanical systems but of realistic complexity (e.g., allowing for anharmonicity) exhibit sensitivity to initial conditions by which one means that two rather similar initial states follow quite diverging trajectories. If the initial state is not sharply defined then its subsequent evo-... [Pg.3]

This leads to further information which can be obtained by using the spectroscopic mode of operation. In this mode the tunneling current is determined as a function of the applied bias voltage thus additionally aUowing to determine the electronic structure of the sample surface down to the atomic scale. [Pg.18]

In its simplest expression, EELS can be performed in energy-filtered (EE-TEM) or ESI mode, i.e., to acquire elemental maps, but EELS in spectroscopic mode is best suited for quantitative analysis, with a high energy and lateral resolution. [Pg.3096]

Spectroscopic mode also referred to as Bunched mode. This is used when optimal secondary ion mass resolution is needed. Note This comes at the cost of image spatial resolution. [Pg.228]

Figure 5.14 Pictorial illustration (not to scale) of (a) Imaging mode, (b) Spectroscopic mode, and (c) the use of Burst mode while in Spectroscopic mode for improved signal intensity. In the respective insets are shown the resulting mass spectra for the same secondary ions. The parameters At and Afj refer to pulse width and time between pulses, respectively. Figure 5.14 Pictorial illustration (not to scale) of (a) Imaging mode, (b) Spectroscopic mode, and (c) the use of Burst mode while in Spectroscopic mode for improved signal intensity. In the respective insets are shown the resulting mass spectra for the same secondary ions. The parameters At and Afj refer to pulse width and time between pulses, respectively.
Spectroscopic mode, also referred to as Bunched mode, brings together the ions within a particular primary ion pulse such that they arrive at the sample s surface... [Pg.229]

The SPR measurement can be performed, as with other optical measurements, in two modes. Used in a spectroscopic mode, i.e. by measuring and analysing the entire resonance spectrum, SPR provides a tool... [Pg.1133]

Table 1. Percentage errors in the calculation of the spectroscopic mode ... Table 1. Percentage errors in the calculation of the spectroscopic mode ...
A wide variety of spectroelectrochemical methods is available and developments continue apace. Figure 1 contains a classification of methods by spectroscopic mode. Some techniques involve one or more modes of absorption, luminescence, or emission, e.g.. X-ray or Mossbauer, so a rigorous and comprehensive classification has not been attempted. Mass spectrometry... [Pg.2]


See other pages where Spectroscopic mode is mentioned: [Pg.210]    [Pg.333]    [Pg.307]    [Pg.307]    [Pg.120]    [Pg.129]    [Pg.150]    [Pg.307]    [Pg.18]    [Pg.37]    [Pg.137]    [Pg.4622]    [Pg.206]    [Pg.604]    [Pg.441]    [Pg.218]    [Pg.229]    [Pg.329]    [Pg.398]    [Pg.417]    [Pg.417]    [Pg.896]    [Pg.69]    [Pg.77]    [Pg.100]    [Pg.101]    [Pg.204]    [Pg.257]    [Pg.710]    [Pg.189]    [Pg.190]   
See also in sourсe #XX -- [ Pg.228 ]