Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Equipment for Extraction

G Scarano, M Esposito, L Grasso, V Soprano, G Oliviero. Use of automated solid-phase extraction equipment for the determination of ivermectin residues in animal liver by HPLC. Analyst 123 2541 -2553, 1998. [Pg.692]

Familiarity with the materials and/or lack of knowledge of the risks involved can lead to complacency. Figure 2 illustrates the use of portable extraction equipment for the removal of styrene fumes during work with polyester resins in a gallery situation. The operators are also using filtered-air supply hoods for the removal of dust and nuisance... [Pg.59]

Drop Diameter. In extraction equipment, drops are initially formed at distributor no22les in some types of plate column the drops are repeatedly formed at the perforations on each plate. Under such conditions, the diameter is determined primarily by the balance between interfacial forces and buoyancy forces at the orifice or perforation. For an ideal drop detaching as a hemisphere from a circular orifice of diameter and then becoming spherical ... [Pg.69]

The earliest large-scale continuous industrial extraction equipment consisted of mixer—settlers and open-spray columns. The vertical stacking of a series of mixer—settlers was a feature of a patented column in 1935 (96) in which countercurrent flow occurred because of density difference between the phases, avoiding the necessity for interstage pumping. This was a precursor of the agitated column contactors which have been developed and commercialized since the late 1940s. There are several texts (1,2,6,97—98) and reviews (99—100) available that describe the various types of extractors. [Pg.70]

In order to make a multipurpose plant even more versatile than module IV, equipment for unit operations such as soHd materials handling, high temperature/high pressure reaction, fractional distillation (qv), Hquid—Hquid extraction (see Extraction, liquid-liquid), soHd—Hquid separation, thin-film evaporation (qv), dryiag (qv), size reduction (qv) of soHds, and adsorption (qv) and absorption (qv), maybe iastalled. [Pg.438]

The other common objective for calculating the number of countercurrent theoretical stages (or mass-transfer units) is to evaluate the performance of hquid-liquid extraction test equipment in a pilot plant or to evaluate production equipment in an industrial plant. Most liq-uid-hquid extraction equipment in common use can oe designed to achieve the equivalent of 1 to 8 theoretical countercurrent stages, with some designed to achieve 10 to 12 stages. [Pg.1460]

Mixer-Settler Equipment The equipment for extraction or chemical reaction may be classified as follows ... [Pg.1637]

Environmental monitoring of chloroacetanilides requires methods that have the capability to distinguish between complex arrays of related residues. The two example methods detailed here for water monitoring meet this requirement, but the method for metabolites requires sophisticated mass spectral equipment for the detection of directly injected water samples. In the near term, some laboratories may need to modify this method by incorporation of an extraction/concentration step, such as SPE, that would allow for concentration of the sample, so that a less sensitive and, correspondingly, less expensive, mass spectral detector can be used. However, laboratories may want to consider purchasing a sensitive instrument rather than spending time on additional wet chemistry procedures. In the future, sensitive instrumentation may be less expensive and available to all laboratories. Work is under way to expand the existing multi-residue methods to include determination of additional chloroacetanilides and their metabolites in both water and soil samples. [Pg.387]

Convention on Control of Transboundary Movements of Hazardous Wastes and their Disposal and 69 ratified the ban on all kinds of hazardous waste export from wealthy OECD-countries to non-OECD countries, large amounts of waste electrical and electronic equipment (WEEE) are shipped overseas for recycling, the majority to China as reported by Brigden et al. [2] and Puckett et al. [3], lesser quantities to India and Western Africa reported by Kuper and Hojsik [4]. WEEE contains a variety of harmful substances like endocrine disruptors and persistent organic pollutants (POPs). Additionally, hazardous substances may be formed during informal recycling. This often practised informal treatment without proper equipment for metal extraction and labour safety heavily affects the environment and human health of workers and the inhabitants of whole stretches of land. [Pg.315]

As a consequence of the development of extraction methods for STA based on mixed-mode SPE columns, as well as of the recent introduction of instruments for the automated sample preparation allowing efficient evaporation and derivatization of the extracts, full automation of STA methods based on GC-MS analysis is also available. It needs GC-MS instalments equipped with an HP PrepStation System. The samples directly injected by the PrepStation are analyzed by full scan GC-MS. Using macrocommands, peak identification and reporting of the results are also automated. Each ion of interest is automatically selected, retention time is calculated, and the peak area is determined. All data are checked for interference, peak selection, and baseline determination. [Pg.315]

It is best to wash extraction equipment using the pure extracting solution to be used in the primary extraction. For example, if an aqueous acid solution is to be used, then this same solution should be used in cleaning equipment. This is also true when an organic extractant is to be used. When water is to be... [Pg.252]

The selection of the equipment for an extraction process is influenced by the factors which are responsible for limiting the extraction rate. Thus, if the diffusion of the solute through... [Pg.502]


See other pages where Equipment for Extraction is mentioned: [Pg.330]    [Pg.358]    [Pg.2563]    [Pg.1749]    [Pg.352]    [Pg.63]    [Pg.1743]    [Pg.120]    [Pg.213]    [Pg.330]    [Pg.358]    [Pg.2563]    [Pg.1749]    [Pg.352]    [Pg.63]    [Pg.1743]    [Pg.120]    [Pg.213]    [Pg.368]    [Pg.567]    [Pg.56]    [Pg.69]    [Pg.72]    [Pg.91]    [Pg.136]    [Pg.179]    [Pg.88]    [Pg.489]    [Pg.366]    [Pg.708]    [Pg.599]    [Pg.286]    [Pg.641]    [Pg.643]    [Pg.567]    [Pg.87]    [Pg.135]    [Pg.136]    [Pg.1008]    [Pg.34]    [Pg.41]    [Pg.309]    [Pg.463]    [Pg.102]    [Pg.130]    [Pg.725]   
See also in sourсe #XX -- [ Pg.624 , Pg.625 , Pg.626 , Pg.627 , Pg.628 , Pg.629 , Pg.630 , Pg.631 ]