Elements, analytical determination

The element by element analytical determination using conventional techniques would be very laborious and time-consuming for a solution as complex as the simulated HLLW. [Pg.201]

In developing theoretical problems he always thought about practical uses of results in the national economy. His theoretical and experimental results were applied to developing numerous methods of analytical determination of elements in complex natural and technical situations, and also he also used the principles for improving the university curriculum and to generate new special courses. [Pg.6]

Minerals generally present difficult problems in chemical analysis, and these problems grow more serious when the elements being determined are as difficult to separate as are those named above. The time and effort that x-ray emission spectrography can save are therefore great, but there are obstacles to be surmounted. Among these are (1) Absorption and enhancement effects are often serious. (2) The element of interest may be present at low concentration in a matrix that is unknown and variable. (3) Satisfactory standards are not always easy to obtain. (4) Simple equipment sometimes does not resolve important analytical lines- completely. (5) Sample preparation and particle size often influence the intensities of analytical lines Class II deviations (7.8) can be particularly serious with minerals. [Pg.199]

Since the sulphone group contains sulphur in its highest oxidation state, specific analytical procedures based on controlled oxidation are not possible. The complete molecule can be submitted to oxidative degradation, e.g. in the elemental sulphur determination, methods for which, as stated above, will not be included here. [Pg.108]

Lingane and Niedrach have claimed that the h-VI states of tellurium (or selenium) are not reduced at the dropping electrode under any of the conditions of then-investigation however, Norton et al. [42] showed that under a variety of conditions, samples of telluric acid prepared by several different procedures do exhibit well-defined (though irreversible) waves, suitable for the analytical determination of the element. The reduction of Te(H-VI) at the dropping electrode was found coulometri-cally to proceed to the -II state (whereas selenate, Se(-i-VI), was not reduced at the dropping electrode in any of the media reported). [Pg.72]

Discovery of the Periodic Table was rendered possible only after four decisive prerequisites had been achieved. These were (i) the abandonment of the metaphysical and occult notions of elements that typified the alchemical era (ii) the adoption of a modern and workable definition of an element (iii) the development of analytical chemical techniques for the isolation of the elements and determination of their properties and (iv) the devising of a means of associating each element with a characteristic natural number. The Periodic Table made its appearance on cue almost as soon as these preconditions had been fulfilled... [Pg.565]

The application of the Chelex 100 resin separation and preconcentration, with the direct use of the resin itself as the final sample for analysis, is an extremely useful technique. The elements demonstrated to be analytically determinable from high salinity waters are cobalt, chromium, copper, iron, manganese, molybdenum, nickel, scandium, thorium, uranium, vanadium, and zinc. The determination of chromium and vanadium by this technique offers significant advantages over methods requiring aqueous final forms, in view of their poor elution reproducibility. The removal of sodium, chloride, and bromide allows the determination of elements with short and intermediate half-lives without radiochemistry, and greatly reduces the radiation dose received by personnel. This procedure was successfully applied in a study of... [Pg.282]

Soil samples were collected along a traverse over the Honerat kimberlite and extended off the kimberlite approximately 75 m SE and 225 m NW from the pipe s centre (Fig. 1). Although it is common practice to collect samples from upper B-horizon soil (Levinson 1980 Bajc 1998 Mann et al. 2005) our samples were collected from C-horizon soil because GAGI samplers were placed at a depth of 60 cm (well below the B horizon). Within 8 hours of sampling, a portion of each soil sample was mixed with Milli-Q water (1 1) to create a slurry. The values of pH and oxidation-reduction potential (ORP) were determined in each slurry. Ammonia acetate leach of the soil samples were performed at Acme Analytical Laboratories, Vancouver, where 20 ml of ammonium acetate was mixed with 1 g soil sample and elements were determined by inductively coupled plasma-mass spectrometry. The GAGI samplers installed at Unknown were placed in piezometers and submerged in water at a depth of approximately 1 m below ground surface. [Pg.34]

Concentrations of major cations in all samples were determined by acetylene flame Atomic Absorption Spectroscopy at the Trace Element Analytical Laboratories (TEAL) of McGill University. Analyses of trace element concentrations were canied out using Inductively Coupled Plasma Quadrupole Mass Spectrometry (also at TEAL). Concentrations of anions were determined by Ion Chromatography at the Hydrogeology Laboratory at McGill University. [Pg.263]

Analytical and quality control details are summarised in Arne et al (2008). Gold was determined by fire assay, and major elements by ICP-OES following a four-acid digestion, with the exception of fresh drill core samples from Wildwood, which were analysed by lithium borate fusion and XRF. Trace elements were determined by ICP-MS. Refractory elements (W, Zr, Ba and Ti) were analysed by pressed powder XRF. [Pg.274]

The linearity definition is on the slide. As long as the measurement result versus the analyte concentration fits a straight line we call this linearity. In an ideal case hnearity could extend over several orders of magnitude. This is, for example, the case for certain elements when determined by ICP-OES. In other cases it can be less than one order of magnitnde. Linearity over a large concentration can be very time saving, becanse fewer dilation steps might be necessary (see also chapter 9). [Pg.13]

If many analyses of the same type have to be evaluated, it is convenient to prepare a diagram in which the analytically determined content of the appropriate group or element is plotted against the composition both in wt% and in mol% (see Fig. 5.1). It should again be pointed out that the observed values are generally less than the theoretical values for the reasons already mentioned. [Pg.336]

It is not possible to prescribe specific pretreatment procedures here because these can only be decided upon when the system and the purpose of the experiments has been properly defined. However, a wealth of information exist in various biochemical reference books on how to isolate various biological compounds. The recommended techniques and methods could be used as part of the trace element speciation protocol often after slight modification, taking into consideration the following points First, the trace element blank levels have to be low, less than 10% of the total concentration in the sample. Second, the regents used should not interfere with subsequent analytical determinations. Third, the experimental conditions should not deviate markedly from those found in vivo, especially the pH and ionic strength of the medium. [Pg.149]

Quantitative trace element analysis of diamond by LA-ICP-MS using different synthetic multielement carbon based standards (e.g., cellulose pellets) is discussed by Rege et al 2, whereby 13C was used for internal standardization. Concentrations of 41 elements were determined in two fibrous diamonds from Jwaneng Botswana (JWA 110 and 115) by relative sensitivity coefficients measured using the synthetic cellulose standard. The analytical data were verified by means of instrumental neutron activation analysis (INAA) and proton induced X-ray emission (PIXE).72... [Pg.200]

Another type of interference that can arise in the atomiser is called ionisation interferences . Particularly when using hot atomisers, the loss of an electron from the neutral atom in metals with low ionisation energy may occur, thus reducing the free atom population (hence the sensitivity of the analyte determination, for which an atomic line is used, is reduced). These interferences can be suppressed in flames by adding a so-called ionisation suppressor to the sample solution. This consists in adding another element which provides a great excess of electrons in the flame (he. another easily ionisable element). In this way, the ionisation equilibrium is forced to the recombination of the ion with the electron to form the metal atom. Well-known examples of such buffering compounds are salts of Cs and La widely used in the determination of Na, K and Ca by FAAS or flame OES. [Pg.18]

The Determination of Selenium. The most difficult trace element to determine in coal by wet chemical methods is selenium. Two alternative dissolution techniques can be used—H. L. Rooks combustion method (7) and the oxygen bomb combustion method (4). Also, two alternative analytical methods can be used—the hydride evolution method (5) and the graphite furnace method. [Pg.39]

Tncreasing national concern over the ecological and environmental effects of coal combustion coupled with the desire to become more self sufficient in mineral production led the Coal Research Bureau at West Virginia University to examine the major and minor constituents in coal ash. Because of the need for accurate results at the low trace element concentrations, it was felt that atomic absorption spectroscopy could provide a rapid and routine method for analytical determinations. [Pg.65]

There are several factors which make neutron activation analysis (NAA) an appropriate technique for investigating potential pollutants in coal and the combustion process. First, the multi-element nature of NAA is useful because of the large number of potential elemental pollutants, such as Se, Hg, As, Zn, Ni, Sb, and Cd. Also, the use of elemental ratios made possible by the multi-element capability facilitates the understanding of chemical behavior during the combustion process. Elemental ratios have been used previously in urban (15) and upper atmospheric (26) studies. Secondly, the sensitivity and selectivity of NAA allows determination of many elements present at very low concentrations (ppm or lower), and the results are unaffected by matrix interferences. This sensitivity also allows analysis of very small samples. Finally, the cost of NAA when conducted as a multi-element analytical tool is competitive with more conventional and less sensitive techniques on the cost-per-element-per-sample basis. [Pg.128]

Analytical methods employed in soil chemistry include the standard quantitative methods for the analysis of gases, solutions, and solids, including colorimetric, titrimetric, gravimetric, and instrumental methods. The flame emission spectrophotometric method is widely employed for potassium, sodium, calcium, and magnesium barium, copper and other elements are determined in cation exchange studies. Occasionally arc and spark spectrographic methods are employed. [Pg.1499]

Mercury may be present in air in different chemical states such as the elemental form (as a vapour or adsorbed on particular matter) or in the form of volatile mercury compounds (mercury chloride, methyl-mercuric chloride, and dimethyl mercury). Although elemental mercury is only one of the mercury forms which is not as toxic as its organic or ionic forms, analytical determination of elemental mercury is of special importance. Such analysis is used not only for determination of elemental mercury in environment, but also as a method for determination of other forms of mercury after reductive treatment. [Pg.235]

Veal, D.J. (1966) Nondestructive activation analysis of crude oils for arsenic to one part per billion, and simultaneous determination of five other trace elements. Analytical Chemistry, 38(8), 1080-83. [Pg.231]


See other pages where Elements, analytical determination is mentioned: [Pg.234]    [Pg.31]    [Pg.112]    [Pg.593]    [Pg.654]    [Pg.425]    [Pg.425]    [Pg.426]    [Pg.426]    [Pg.44]    [Pg.60]    [Pg.265]    [Pg.259]    [Pg.570]    [Pg.326]    [Pg.333]    [Pg.518]    [Pg.42]    [Pg.123]    [Pg.196]    [Pg.279]    [Pg.318]    [Pg.356]    [Pg.517]    [Pg.44]    [Pg.250]    [Pg.254]   