Electron capture method

In interpreting the data for the total petroleum hydrocarbons in a sample, the amount of moisture cannot be ignored because moistme blocks the extraction of petroleum hydrocarbons by another hydrocarbon (Freon). Potentially, sulfm or phthalate compounds also interfere with total petroleum hydrocarbons analyses. This is similar to the problem of strong interferences from phthalate esters or chlorinated solvents when one is using electron capture methods to look for chlorinated compounds such as polycholorbiphenyls or pesticides. [Pg.232]

In Fig. 8.15, the values of hvCT are plotted against the half-wave potentials of the acceptors measured in acetonitrile. A near-linear relation is observed. Peover also obtained, by an electron capture method, the values of EA of aromatic hydrocarbons in the gas phase and confirmed a near-linear relation with the reduction potentials in the solution phase. [Pg.249]

The electron capture method, although very sensitive, does suffer from reproducibility problems, the ionization efficiency and mass spectral patterns being influenced by small changes in operating parameters such as the mass spectrometer ion source temperature. [Pg.314]

The special problems for vaUdation presented by chiral separations can be even more burdensome for gc because most methods of detection (eg, flame ionization detection or electron capture detection) in gc destroy the sample. Even when nondestmctive detection (eg, thermal conductivity) is used, individual peak collection is generally more difficult than in Ic or tic. Thus, off-line chiroptical analysis is not usually an option. Eortunately, gc can be readily coupled to a mass spectrometer and is routinely used to vaUdate a chiral separation. [Pg.71]

There are four modes of radioactive decay that are common and that are exhibited by the decay of naturally occurring radionucHdes. These four are a-decay, j3 -decay, electron capture and j3 -decay, and isomeric or y-decay. In the first three of these, the atom is changed from one chemical element to another in the fourth, the atom is unchanged. In addition, there are three modes of decay that occur almost exclusively in synthetic radionucHdes. These are spontaneous fission, delayed-proton emission, and delayed-neutron emission. Lasdy, there are two exotic, and very long-Hved, decay modes. These are cluster emission and double P-decay. In all of these processes, the energy, spin and parity, nucleon number, and lepton number are conserved. Methods of measuring the associated radiations are discussed in Reference 2 specific methods for y-rays are discussed in Reference 1. [Pg.448]

Gas Chromatography. Gas chromatography is a technique utili2ed for separating volatile substances (or those that can be made volatile) between two phases, one of which is a gas. Purge-and-trap methods are frequently used for trace analysis. Various detectors have been employed in trace analysis, the most commonly used being flame ioni2ation and electron capture detectors. [Pg.244]

The analysis of mefloquine in blood, using packed-column sfc, a mobile phase consisting of / -pentane modified with 1% methanol and 0.15% -butylamine, and electron capture detection has been reported (92). The method compares favorably to a previously pubflshed hplc-based procedure having a detection limit of 7.5 ng/mLin 0.1 mL blood sample. [Pg.247]

For carrying out of given researches method of synthetic pyrethroids determination in air has been developed. Chromatographic behaviour is investigated and optimum conditions of the synthetic pyrethroids analysis with application of capillary column with stationary phase DB-5 and electron-capture detector are selected. [Pg.217]

Ethylene dibromide Lab method with pumped Tenax absorbent tubes, solvent desorption and electron capture gas chromatography 45... [Pg.361]

Ionisation detectors. An important characteristic of the common carrier gases is that they behave as perfect insulators at normal temperatures and pressures. The increased conductivity due to the presence of a few charged molecules in the effluent from the column thus provides the high sensitivity which is a feature of the ionisation based detectors. Ionisation detectors in current use include the flame ionisation detector (FID), thermionic ionisation detector (TID), photoionisation detector (PID) and electron capture detector (ECD) each, of course, employing a different method to generate an ion current. The two most widely used ionisation detectors are, however, the FID and ECD and these are described below. [Pg.242]

A very sensitive method for the determination of MCA in surfactants is a gas chromatographic one [249]. The method is based on the derivatization of the sample with ethanol and subsequent extraction of the derived ester with cyclohexane. The acids are identified and qualified gas chromatographically by the use of an electron capture detector and two capillary columns of varying polarities. The detection limit is 0.2 ppm. [Pg.349]

The primary method for detecting methyl parathion and metabolites in biological tissues is gas chromatography (GC) coupled with electron capture (BCD), flame photometric (FPD), or flame ionization detection (FID). Sample preparation for methyl parathion analysis routinely involves extraction with an organic solvent (e g., acetone or benzene), centrifugation, concentration, and re suspension in a suitable solvent prior to GC analysis. For low concentrations of methyl parathion, further cleanup procedures, such as column chromatography on silica gel or Florisil are required. [Pg.175]

The method of choice for the determination of a- and P-endosulfan in blood, urine, liver, kidney, brain, and adipose tissue is gas chromatography equipped with an electron capture detector (GC/ECD) (Coutselinis et al. 1976 Demeter and Heyndrickx 1979 Demeter et al. 1977 Le Bel and Williams 1986). This is because GC/ECD is relatively inexpensive, simple to operate, and offers a high sensitivity for halogens (Griffith and Blanke 1974). After fractionation of adipose tissue extracts using gel permeation chromatography, detection limits of low-ppb (1.2 ng/g) were achieved for endosulfan and other chlorinated pesticides using GC/ECD (Le Bel and Williams 1986). [Pg.248]

EPA. 1997d. Methods and guidance for analysis of water. Method 508 Determination of chlorinated pesticides in water by gas chromatography with an electron capture detector. U.S. Environmental Protection Agency, Washington, DC. EPA 821-C-97-001. [Pg.290]

Several methods are available for the analysis of trichloroethylene in biological media. The method of choice depends on the nature of the sample matrix cost of analysis required precision, accuracy, and detection limit and turnaround time of the method. The main analytical method used to analyze for the presence of trichloroethylene and its metabolites, trichloroethanol and TCA, in biological samples is separation by gas chromatography (GC) combined with detection by mass spectrometry (MS) or electron capture detection (ECD). Trichloroethylene and/or its metabolites have been detected in exhaled air, blood, urine, breast milk, and tissues. Details on sample preparation, analytical method, and sensitivity and accuracy of selected methods are provided in Table 6-1. [Pg.229]

Residue analytical chemistry has extended its scope in recent decades from the simple analysis of chlorinated, lipophilic, nonpolar, persistent insecticides - analyzed in the first Si02 fraction after the all-destroying sulfuric acid cleanup by a gas chro-matography/electron capture detection (GC/ECD) method that was sometimes too sensitive to provide linearity beyond the required final concentration - to the monitoring of polar, even ionic, hydrophilic pesticides with structures giving the chemist no useful feature other than the molecule itself, hopefully to be ionized and fragmented for MS or MS" detection. [Pg.59]

On the other hand, if only specific GC detectors, e.g. the electron capture, nitrogen-phosphorus or flame photometric detectors, are tested, the argument of lack of GC method sensitivity is not acceptable. In most cases mass spectrometric detectors provide the sensitivity and selectivity needed. Unfortunately, tandem mass spectrometry (MS/MS) or MS" detectors for GC are still not widely used in official laboratories, and therefore these techniques are not always accepted for enforcement methods. [Pg.108]

For multi-analyte and/or multi-matrix methods, it is not possible to validate a method for all combinations of analyte, concentration and type of sample matrix that may be encountered in subsequent use of the method. On the other hand, the standards EN1528 andEN 12393 consist of a range of old multi-residue methods. The working principles of these methods are accepted not only in Europe, but all over the world. Most often these methods are based on extractions with acetone, acetonitrile, ethyl acetate or n-hexane. Subsequent cleanup steps are based on solvent partition steps and size exclusion or adsorption chromatography on Florisil, silica gel or alumina. Each solvent and each cleanup step has been successfully applied to hundreds of pesticides and tested in countless method validation studies. The selectivity and sensitivity of GC combined with electron capture, nitrogen-phosphorus, flame photometric or mass spectrometric detectors for a large number of pesticides are acceptable. [Pg.113]

Analytical methods for parent chloroacetanilide herbicides in soil typically involve extraction of the soil with solvent, followed by solid-phase extraction (SPE), and analysis by gas chromatography/electron capture detection (GC/ECD) or gas chromatog-raphy/mass spectrometry (GC/MS). Analytical methods for parent chloroacetanilides in water are similarly based on extraction followed by GC with various detection techniques. Many of the water methods, such as the Environmental Protection Agency (EPA) official methods, are multi-residue methods that include other compound classes in addition to chloroacetanilides. While liquid-liquid partitioning was used initially to extract acetanilides from water samples, SPE using... [Pg.345]


See other pages where Electron capture method is mentioned: [Pg.292]    [Pg.315]    [Pg.292]    [Pg.315]    [Pg.576]    [Pg.577]    [Pg.476]    [Pg.233]    [Pg.69]    [Pg.274]    [Pg.336]    [Pg.207]    [Pg.1029]    [Pg.113]    [Pg.37]    [Pg.248]    [Pg.91]    [Pg.333]    [Pg.344]    [Pg.37]    [Pg.113]    [Pg.26]    [Pg.30]    [Pg.79]    [Pg.80]    [Pg.3]    [Pg.316]    [Pg.327]    [Pg.345]    [Pg.387]    [Pg.390]   