Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Electrically filament

Pulse-mode pyrolyzers include resistively-heated electrical filaments or ribbons and radio frequency induction-heated wires [841,842,846,848,849]. The filament or ribbon-type pyrolyzers are simple to construct. Figure 8.45, and typically consist of an inert wire or ribbon (Pt or Pt-Rh alloy) connected to a high-current power supply. Samples soluble in a volatile solvent are applied to the fileutent as a thin film. Insoluble materials are placed in a crucible or quartz tube, heated by a basket-lilce shaped or helical wound filiunent. The coated filament is contained within a low dead volume chamber through which the carrier gas flows, sweeping the pyrolysis products onto the column. The surface temperatui of the filament is raised rapidly from ambient temperature to He equilibrium pyrolysis temperature. This... [Pg.973]

Always use red or yellow photographic dark room light bulbs during any step of LSD manufacture. Direct sunlight, electric filament, or fluorescent light bulbs (etc.) will hurt the above compounds. Dark room bulbs are cheap and are a must. [Pg.61]

USE As substitute for platinum in jewelry for pen nibs as hardener in electrical contact alloys, electrical filaments in ceramic colors catalyst in synthesis of long chain hydrocarbons. [Pg.1319]

Modem light sources used in these four general approaches to workplace illumination are t5rpically of two kinds electric filament lamps and fluorescent tubes. Following are the advantages and drawbacks of these two light sources ... [Pg.1198]

A device for detecting and measuring flammable gases based on their reaction with an electric filament. The resulting combustion and rise in temperature can be detected electronically and displayed as a concentration in air. [Pg.97]

Electric filament mount structures (incandescent and fluorescent lamps)... [Pg.399]

Like corona, plasma is the electrical ionization of a gas. An atmospheric chemical plasma (glow) discharge creates a smooth, undifferentiated cloud of ionized gas with no visible electrical filaments. Unlike corona, plasma is created at much lower voltage levels. [Pg.75]

The acconunodation coefficient for Kr on a carbon filament is determined experimentally as follows. The electrically heated filament at temperature 72 is stretched down the center of a cylindrical cell containing Kr gas at 7. Gas molecules hitting the filament cool it, and to maintain its temperature a resistance heating of Q cal sec cm is needed. Derive from simple gas kinetic theory the expression... [Pg.672]

The boron so obtained is an amorphous powder. It can be obtained in the crystalline state by reducing the vapour of boron tribromide with hydrogen, either in an electric arc or in contact with an electrically-heated tungsten filament ... [Pg.141]

Boron exists naturally as 19.78% lOB isotope and 80.22% IIB isotope. High-purity crystalline boron may be prepared by the vapor phase reduction of boron trichloride or tribromide with hydrogen on electrically heated filaments. The impure or amorphous, boron, a brownish-black powder, can be obtained by heating the trioxide with magnesium powder. [Pg.13]

It is used in certain nickel-based alloys, such as the "Hastelloys(R)" which are heat-resistant and corrosion-resistant to chemical solutions. Molybdenum oxidizes at elevated temperatures. The metal has found recent application as electrodes for electrically heated glass furnaces and foreheaths. The metal is also used in nuclear energy applications and for missile and aircraft parts. Molybdenum is valuable as a catalyst in the refining of petroleum. It has found applications as a filament material in electronic and electrical applications. Molybdenum is an... [Pg.78]

Thermal Conductivity Detector One of the earliest gas chromatography detectors, which is still widely used, is based on the mobile phase s thermal conductivity (Figure 12.21). As the mobile phase exits the column, it passes over a tungsten-rhenium wire filament. The filament s electrical resistance depends on its temperature, which, in turn, depends on the thermal conductivity of the mobile phase. Because of its high thermal conductivity, helium is the mobile phase of choice when using a thermal conductivity detector (TCD). [Pg.569]

When a solute elutes from the column, the thermal conductivity of the mobile phase decreases and the temperature of the wire filament, and thus its resistance, increases. A reference cell, through which only the mobile phase passes, corrects for any time-dependent variations in flow rate, pressure, or electrical power, ah of which may lead to a change in the filament s resistance. [Pg.569]

Fundamentally, introduction of a gaseous sample is the easiest option for ICP/MS because all of the sample can be passed efficiently along the inlet tube and into the center of the flame. Unfortunately, gases are mainly confined to low-molecular-mass compounds, and many of the samples that need to be examined cannot be vaporized easily. Nevertheless, there are some key analyses that are carried out in this fashion the major one i.s the generation of volatile hydrides. Other methods for volatiles are discussed below. An important method of analysis uses lasers to vaporize nonvolatile samples such as bone or ceramics. With a laser, ablated (vaporized) sample material is swept into the plasma flame before it can condense out again. Similarly, electrically heated filaments or ovens are also used to volatilize solids, the vapor of which is then swept by argon makeup gas into the plasma torch. However, for convenience, the methods of introducing solid samples are discussed fully in Part C (Chapter 17). [Pg.98]

Thermospray interface. Provides liquid chromatographic effluent continuously through a heated capillary vaporizer tube to the mass spectrometer. Solvent molecules evaporate away from the partially vaporized liquid, and analyte ions are transmitted to the mass spectrometer s ion optics. The ionization technique must be specified, e.g., preexisting ions, salt buffer, filament, or electrical discharge. [Pg.433]

The source requited for aes is an electron gun similar to that described above for electron microscopy. The most common electron source is thermionic in nature with a W filament which is heated to cause electrons to overcome its work function. The electron flux in these sources is generally proportional to the square of the temperature. Thermionic electron guns are routinely used, because they ate robust and tehable. An alternative choice of electron gun is the field emission source which uses a large electric field to overcome the work function barrier. Field emission sources ate typically of higher brightness than the thermionic sources, because the electron emission is concentrated to the small area of the field emission tip. Focusing in both of these sources is done by electrostatic lenses. Today s thermionic sources typically produce spot sizes on the order of 0.2—0.5 p.m with beam currents of 10 A at 10 keV. If field emission sources ate used, spot sizes down to ca 10—50 nm can be achieved. [Pg.283]

Polyesters are also used in continuous filament spunbonded nonwovens (see Nonwoven fabrics). Reemay spunbonded fabric is composed of continuous filament PET with a polyester copolymer binder. These spunbonded fabrics are available in a wide range of thicknesses and basis weights and can be used for electrical insulation, coated fabric substrates, disposable apparel for clean rooms, hospitals, and geotextiles (qv). [Pg.334]

Process. Any standard precursor material can be used, but the preferred material is wet spun Courtaulds special acrylic fiber (SAF), oxidized by RK Carbon Fibers Co. to form 6K Panox B oxidized polyacrylonitrile (PAN) fiber (OPF). This OPF is treated ia a nitrogen atmosphere at 450—750°C, preferably 525—595°C, to give fibers having between 69—70% C, 19% N density less than 2.5 g/mL and a specific resistivity under 10 ° ohm-cm. If crimp is desired, the fibers are first knit iato a sock before heat treating and then de-knit. Controlled carbonization of precursor filaments results ia a linear Dow fiber (LDF), whereas controlled carbonization of knit precursor fibers results ia a curly carbonaceous fiber (EDF). At higher carbonizing temperatures of 1000—1400°C the fibers become electrically conductive (22). [Pg.69]


See other pages where Electrically filament is mentioned: [Pg.357]    [Pg.366]    [Pg.357]    [Pg.197]    [Pg.1311]    [Pg.1148]    [Pg.370]    [Pg.147]    [Pg.1183]    [Pg.389]    [Pg.1239]    [Pg.357]    [Pg.366]    [Pg.357]    [Pg.197]    [Pg.1311]    [Pg.1148]    [Pg.370]    [Pg.147]    [Pg.1183]    [Pg.389]    [Pg.1239]    [Pg.408]    [Pg.1312]    [Pg.1895]    [Pg.2803]    [Pg.51]    [Pg.56]    [Pg.78]    [Pg.199]    [Pg.15]    [Pg.45]    [Pg.45]    [Pg.114]    [Pg.118]    [Pg.121]    [Pg.322]    [Pg.234]    [Pg.334]    [Pg.310]    [Pg.15]    [Pg.69]    [Pg.128]   
See also in sourсe #XX -- [ Pg.123 ]




SEARCH



Carbon filament electric lamp

Filaments, Electric Lamp

© 2024 chempedia.info