Bioluminescence detector Charge-coupled device Contactless-conductivity detector Capillary electrophoresis Capillary electrophoresis-Electrochemistry Collision-induced dissociation Chemiluminescence detector Sodium chlorate-nitrobenzene Commercial off-the-shelf (U.S. Army) Cold Regions Research and Development Center Croatian Mine Action Center Council of Scientific and Industrial Research,... [Pg.326]

The basic instrumentation for capillary electrophoresis is shown in Figure 12.41 and includes a power supply for applying the electric field, anode and cathode compartments containing reservoirs of the buffer solution, a sample vial containing the sample, the capillary tube, and a detector. Each part of the instrument receives further consideration in this section. [Pg.601]

Detectors Most of the detectors used in HPLC also find use in capillary electrophoresis. Among the more common detectors are those based on the absorption of UV/Vis radiation, fluorescence, conductivity, amperometry, and mass spectrometry. Whenever possible, detection is done on-column before the solutes elute from the capillary tube and additional band broadening occurs. [Pg.604]

Solutes that do not absorb UV/Vis radiation or undergo fluorescence can be detected by other detectors. Table 12.8 provides a list of detectors used in capillary electrophoresis along with some of their important characteristics. [Pg.604]

Limits of detection become a problem in capillary electrophoresis because the amounts of analyte that can be loaded into a capillary are extremely small. In a 20 p.m capillary, for example, there is 0.03 P-L/cm capillary length. This is 1/100 to 1/1000 of the volume typically loaded onto polyacrylamide or agarose gels. For trace analysis, a very small number of molecules may actually exist in the capillary after loading. To detect these small amounts of components, some on-line detectors have been developed which use conductivity, laser Doppler effects, or narrowly focused lasers (qv) to detect either absorbance or duorescence (47,48). The conductivity detector claims detection limits down to lO molecules. The laser absorbance detector has been used to measure some of the components in a single human cell (see Trace AND RESIDUE ANALYSIS). [Pg.183]

We have developed the method for quantitative analysis of urinary albumin with CE. A capillary electrophoresis systems Nanophor 01 (Institute of Analytical Instmmentation, Russian Academy of Sciences, Saint-Petersburg) equipped with a UV-detector was used to determine analyte. Separation was achieved using 45 cmx30 p.m I.D. fused silica capillary column with UV-detection at 214 nm. [Pg.100]

A capillary electrophoresis systems CAPEE 103R ( Eumex Etd, Saint-Petersburg) equipped with a UV-detector was used to separate and quantify analytes. [Pg.114]

Identification of stmctures of toxic chemicals in environmental samples requires to use modern analytical methods, such as gas chromatography (GC) with element selective detectors (NPD, FPD, AED), capillary electrophoresis (CE) for screening purposes, gas chromatography/mass-spectrometry (GC/MS), gas chromatography / Fourier transform infra red spectrometry (GC/FTIR), nucleai magnetic resonance (NMR), etc. [Pg.416]

A computer program was compiled to work out the ray-tracing of UV detector of high performance capillary electrophoresis at the investigation of 5 and 6 (98MI59). The capacity factor of 5 at different temperature and at different mobile phase compositions was experimentally determined in bonded-phase chromatography with ion suppression (98MI15). [Pg.266]

FIGURE 3-23 Schematic of a carbon-fiber amperometric detector for capillary electrophoresis A, fused silica capillary B, eluent drop C, stainless steel plate RE, reference electrode WE, working electrode, AE, auxiliary electrode. (Reproduced with permission from reference 58.)... [Pg.89]

Describe clearly the challenges of interfacing electrochemical detectors to capillary electrophoresis separation systems. How can these challenges be overcome ... [Pg.99]

For many applications, diode array detection has become routine. A photodiode array was used for simultaneous detection of 100 capillaries in zone electrophoresis and micellar electrokinetic chromatography (MEKC).1516 Deflection of a laser beam by acoustic waves was reported as a means to scan six capillary channels on a microchip.17 The design of a low-noise amperometric detector for capillary electrophoresis has been reported.18... [Pg.428]

Microwave plasma detection has been reviewed [351], also in relation to GC [352,353], Coupling of chromatography (GC, SFC, HPLC) and capillary electrophoresis (CE) with ICP-MS and MIP-MS detectors has also been reviewed [181,334,335]. Various specific GC-ICP-MS reviews have appeared [334,337,345,346,354,355]. [Pg.474]

Valproic acid has been determined in human serum using capillary electrophoresis and indirect laser induced fluorescence detection [26], The extract is injected at 75 mbar for 0.05 min onto a capillary column (74.4 cm x 50 pm i.d., effective length 56.2 cm). The optimized buffer 2.5 mM borate/phosphate of pH 8.4 with 6 pL fluorescein to generate the background signal. Separation was carried out at 30 kV and indirect fluorescence detection was achieved at 488/529 nm. A linear calibration was found in the range 4.5 144 pg/mL (0 = 0.9947) and detection and quantitation limits were 0.9 and 3.0 pg/mL. Polonski et al. [27] described a capillary isotache-phoresis method for sodium valproate in blood. The sample was injected into a column of an EKI 02 instrument for separation. The instrument incorporated a conductimetric detector. The mobile phase was 0.01 M histidine containing 0.1% methylhydroxycellulose at pH 5.5. The detection limit was 2 pg/mL. [Pg.230]

Parameters that should be tested in HPLC method development are flow rate, column temperature, batch and supplier of the column, injection volume, mobile phase composition and buffer pH, and detection wavelength [2], For GC/GLC methods, one should investigate the effects of column temperature, mobile phase flow rate, and column lots or suppliers [38], For capillary electrophoresis, changes in temperature, buffer pH, ionic strength, buffer concentrations, detector wavelength, rinse times, and capillaries lots and supplier should be studied [35, 36], Typical variation such as extraction time, and stability of the analytical solution should be also evaluated [37],... [Pg.256]

Organolead and organoselenium compounds were separated satisfactorily by high-performance capillary electrophoresis, using /1-cyclodextrin-modified micellar electroki-netic chromatography with on-column UVV detector set at 210 nm130. [Pg.442]

Capillary electrophoresis narrow-bore fused-silica capillary tube injection system detector recorder orVDU. [Pg.170]


See other pages where Capillary electrophoresis, detector is mentioned: [Pg.532]    [Pg.532]    [Pg.605]    [Pg.609]    [Pg.771]    [Pg.89]    [Pg.90]    [Pg.163]    [Pg.205]    [Pg.162]    [Pg.78]    [Pg.263]    [Pg.267]    [Pg.57]    [Pg.386]    [Pg.436]    [Pg.470]    [Pg.273]    [Pg.274]    [Pg.275]    [Pg.395]    [Pg.642]    [Pg.26]    [Pg.127]    [Pg.55]    [Pg.397]    [Pg.124]    [Pg.133]    [Pg.596]    [Pg.131]    [Pg.177]    [Pg.377]   
See also in sourсe #XX -- [ Pg.176 ]

See also in sourсe #XX -- [ Pg.236 ]

See also in sourсe #XX -- [ Pg.176 ]

See also in sourсe #XX -- [ Pg.203 ]




SEARCH



Detector for capillary electrophoresis

Detector in capillary electrophoresis

Detectors capillary zone electrophoresis

Diode array detector capillary electrophoresis

Electrophoresis detectors

Fluorescence detector capillary electrophoresis

High performance capillary electrophoresis detectors