Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Counting upper limit

The solutions describe the vibrational modes of the system. As waves, the solutions are characterized by integers p which essentially count the number of nodes along the chain in a particular mode of vibration. The upper limit of p corresponds to the number of subchains in the molecule N, . [Pg.187]

C22-0114. The amount of radioactive carbon in any once-living sample eventually drops too low for accurate dating. This detection limit is about 0.03/g min, whereas fresh samples exhibit a count rate of 15.3/g min. What is the upper limit for age determinations using carbon dating ... [Pg.1621]

TC, lamivudine ABC, abacavir APV, amprenavir AST, aspartate aminotransferase ALT, alanine aminotransferase ATV, atazanavir CBC, complete blood cell count D/C, discontinue ddl, didano-sine d4T, stavudine EFV, efavirenz FTC, emtricitabine P1BV, hepatitis B virus F1CV, hepatitis C vims HIV, human immunodeficiency virus IDV, indinavir IV, intravenous LFT, liver function tests LPV/r, lopinavir + ritonavir NNRTI, nonnucleoside reverse transcriptase inhibitor NRTI, nucleoside reverse transcriptase inhibitor NVP, nevirapine PI, protease inhibitor PT, prothrombin time T.bili, total bilirubin TDF, tenofovir disoproxiI fumarate TPV, tipranavir ULN, upper limit of normal ZDV, zidovudine. [Pg.1271]

Patients should have blood urea nitrogen, serum creatinine, aspartate transaminase or alanine transaminase, and a complete blood count determined at baseline and periodically, depending on the presence of other factors that may increase the likelihood of toxicity (advanced age, alcohol abuse, and possibly pregnancy). Hepatotoxicity should be suspected in patients whose transaminases exceed five times the upper limit of normal or whose total bilirubin exceeds 3 mg/dL. At this point, the offending agent(s) should be discontinued, and alternatives selected. [Pg.555]

The fraction of slide surface to be covered by collected droplets is an important factor influencing overall measurement accuracy and time. If the slide is covered by too many droplets, the measurement error and time will increase due to droplet overlap and tedious counting. If too few droplets are collected, the sample may not be large enough to generate statistically representative data. For the measurement accuracy and ease, a coverage of 0.2% has been found to be sufficient and satisfactory with an upper limit of 1.0%. 1 ... [Pg.402]

The 13C NMR study utilized cross polarization-magic angle spinning (CP-MAS) with spin counting. The elemental and functional group analyses provided input for a series of analytical constraints calculations that yield an absolute upper limit for the amount of aromatic carbon and most probable estimates of both aromatic and non-carboxyl aliphatic carbon in each sample. Spin counting experiments demonstrate that less than 50% of the... [Pg.282]

Setting Upper Limits When No Counts are Observed... [Pg.576]

It can be shown that the upper limit on the rate (when zero counts are observed), A0,... [Pg.576]

Example Suppose you are attempting to observe a process that should produce 1 decay per week, and you observe no counts (with a 100% efficient detector) in 4 weeks. At the 95% confidence level, the upper limit on the decay rate is... [Pg.576]

Fig. 11. Search for superheavy nuclides in the reaction of 48Ca with 248Cm upper limits of production cross sections plotted versus half-life. The curves refer to different separation techniques (see text) recoil-fragment separators (curves 1, 2), fast on-line chemistry (3-5), and off-line chemistry with low-background counting (6-8). From P. Armbruster et al. [100]. Fig. 11. Search for superheavy nuclides in the reaction of 48Ca with 248Cm upper limits of production cross sections plotted versus half-life. The curves refer to different separation techniques (see text) recoil-fragment separators (curves 1, 2), fast on-line chemistry (3-5), and off-line chemistry with low-background counting (6-8). From P. Armbruster et al. [100].
Answer. In the manner of the cubic Mg clusters, the external R ligands may impose an upper limit on eve count, but the highly inter-connected cluster core may also permit both lower counts and open-shell electronic configurations even without the five d functions of a transition metal. As shown in Exercise 3.15, if we invoke full radial and tangential bonding for the inner centered cluster but only radial... [Pg.200]

Calcium-41 Ca-41 is produced by neutron activation of natural Ca-40. It has been found to exceed the GQ by a factor of 2 in both graphite fuel struts and desiccant from HNA (3 streams). The reported desiccant value is an upper limit probably based on trace contamination by graphite dust. In decommissioning wastes, activation of the concrete bioshield would also be expected to produce Ca-41 but these wastes streams are regarded as low level wastes in the NIREX inventory and hence GQ values do not apply. Measurements of Ca-41 can be obtained after chemical separation of Ca, which is done routinely for Ca-45 measurements. After any Ca-45 (t 14 =163 days) has decayed away, it can be measured by liquid scintillation counting. Procurement of direct standards from NPL would be required. In fresh samples, if the Ca-45 has been measured, then the Ca-41 could be estimated by comparison of activation... [Pg.119]

The presence of greater than normal amounts of thrombocytes in the circulation is known as thrombocytosis and along with reticulocytosis and leukocytosis is a manifestation of increased activity of the hematopoietic system. Zucker and Woodard (Z2) reported a series of 12 patients with thrombocytosis, consisting of two cases of polycythemia vera, three of essential thrombocytemia, three of chronic granulocytic leukemia, one myeloproliferative syndrome, one erythroleukemia, and one cancer of the bladder. The platelet counts ranged from 685 X 10 to 2500 X 10 per cubic millimeter, all much above the upper limit of normal. [Pg.122]

It is possible to count plaques when some general toxicity is present, but if stain uptake is reduced by more than 50% it will not be possible to obtain reliable values for plaque numbers. In many cases this will put an upper limit on the concentration of test compound for which antiviral efficacy may be determined. [Pg.125]

One of the keys for generating reproducible data is to consider a system s lower detection limit and the upper limits for linear detector response (Beer s law). For instance, coulometric moisture analysis is accurate for samples containing 10 (Xg of H20. Injection of a particularly dry sample may deliver <10 xg of H20,in which case the amount of water measured may not be accurate. Similarly, injecting a dilute sample aliquot may not allow the detection of an impurity present at low levels, so a more concentrated sample preparation may be required. The analysis of a sample preparation more concentrated than those routinely prepared may give detector area count responses beyond the linear response for that compound, making the calculated concentration lower than the true concentration. The injection of a highly concentrated sample may also saturate the detector... [Pg.161]


See other pages where Counting upper limit is mentioned: [Pg.256]    [Pg.376]    [Pg.699]    [Pg.1115]    [Pg.1368]    [Pg.42]    [Pg.376]    [Pg.45]    [Pg.170]    [Pg.445]    [Pg.1082]    [Pg.161]    [Pg.42]    [Pg.257]    [Pg.179]    [Pg.179]    [Pg.126]    [Pg.70]    [Pg.113]    [Pg.183]    [Pg.178]    [Pg.220]    [Pg.12]    [Pg.292]    [Pg.259]    [Pg.273]    [Pg.308]    [Pg.278]    [Pg.200]    [Pg.161]    [Pg.2175]    [Pg.3401]    [Pg.20]    [Pg.207]   


SEARCH



Upper Limit

© 2024 chempedia.info