Level control systems

Direct control system level This is the lowest level of automated system in the production process, including the distributed control system used in production devices and the fundamental automated equipment used offsite. The parameters of the production process are measured and controlled by the automated system. They also receive instruction from the supervisory control system level and accomplish the process operation and control. [Pg.521]

Supervisory control system level The system in this level fulfills supervisory control of main production links in the whole production process. According to the instructions from the sched-... [Pg.521]

If improvements should be achieved by an automation of the inspection process this requires a control of the process parameters of the whole equipment by an integrated "intelligent" system and not by displays still being controlled by the human inspector. This integrated control-system ensures that the inspection conditions are at the highest reproduction level. [Pg.628]

Example 5. There are six dynamometers available for engine testing. The test duration is set at 200 h which is assumed to be equivalent to 20,000 km of customer use. Failed engines are removed from testing for analysis and replaced. The objective of the test is to analy2e the emission-control system. Failure is defined as the time at which certain emission levels are exceeded. [Pg.11]

In the 1990s, the use of batteries in electric vehicles and for load leveling is being revived partly for environmental reasons and partly because of scarce energy resources. Improvements in battery performance and life, fewer maintenance requirements, and automatic control systems are making these appHcations feasible. Research and development is ongoing all over the world to develop improved lead—acid batteries as weU as other systems to meet these needs. [Pg.572]

Absorptive distillation, involving the addition of water to the upper section of a column in the whiskey distillation system, is a method of controlling the level of heavier components in a product. [Pg.85]

Environmental Factors These inchrde (I) eqrripment location, (2) available space, (3) ambient conditions, (4) availabuity of adeqrrate rrtilities (i.e., power, water, etc.) and ancillary-system facilities (i.e., waste treatment and disposal, etc.), (5) maximrrm aUowable emission (air polhrtion codes), (6) aesthetic considerations (i.e., visible steam or water-vapor phrme, etc.), (7) contribrrtions of the air-poUrrtion-control system to wastewater and land poUrrtion, and (8) contribrrtion of the air-poUrrtion-control system to plant noise levels. [Pg.2179]

Provide level control system on filtrate receivers with bottoms pumps... [Pg.103]

The AVR may be designed for variable duty, for automatic control of the reactive power, to the required level through feedback control systems. The machines will now operate only as synchronous condensers without performing any mechanical duty. [Pg.502]

ESPs), and some of the previously discussed novel devices. Series combinations of control devices may be necessary to achieve the required level of particulate matter emission. A commonly used system is a multiple cyclone followed by a fine-particle control system, such as a baghouse, scrubber, or ESP. [Pg.491]

Sulfur dioxide reduction to achieve required emission levels may be accomplished by switching to lower-sulfur fuels. Use of low-sulfur coal or oil, or even biomass such as wood residue as a fuel, may be less expensive than installing an SO2 control system after the process. This is particularly true in the wood products industry, where wood residue is often available at a relatively low cost. [Pg.491]

Effective with the 1982 model year, particulate matter from diesel vehicles was regulated by the U.S. Environmental Protection Agency for the first time, at a level of 0.37 gm km . Diesel vehicles were allowed to meet an NO level of 0.93 gm km under an Environmental Protection Agency waiver. These standards were met by a combination of control systems, primarily exhaust gas recirculation and improvements in the combustion process. For the 1985 model year, the standards decreased to 0.12 gm of particulate matter per kilometer and 0.62 gm of NO per kilometer. This required the use of much more extensive control systems (1). The Clean Air Act Amendments of 1990 (2) have kept the emission standards at the 1985 model level with one exception diesel-fueled heavy trucks shall be required to meet an NO standard of 4.0 gm per brake horsepower hour. [Pg.526]

The gas turbine is a complex system. A typical control system with hierarchic levels of automation is shown in Figure 19-3. The control system at the plant level consists of a D-CS system, which in many new installations is connected to a condition monitoring system and an optimization system. The D-CS system is what is considered to be a plant level system and is connected to the three machine level systems. It can, in some cases, also be connected to functional level systems such as lubrication systems and fuel handling systems. In those cases, it would give a signal of readiness from those systems to the machine level systems. The condition monitoring system... [Pg.636]

Pressure can also be controlled by variable heat transfer coefficient in the condenser. In this type of control, the condenser must have excess surface. This excess surface becomes part of the control system. One example of this is a total condenser with the accumulator running full and the level up in the condenser. If the pressure is too high, the level is lowered to provide additional cooling, and vice versa. This works on the principle of a slow moving liquid film having poorer heat transfer than a condensing vapor film. Sometimes it is necessary to put a partially flooded condenser at a steep angle rather than horizontal for proper control response. [Pg.66]

Use of excess air levels of 5 percent or less has been shown to reduce fuel ash corrosion in furnaces, most likely by stabilizing the vanadium as a refractory suboxide, VO2 or V2O3. Utility plants have had some success using this method to control vanadium ash corrosion. However, practical application of excess air control in refinery and chemical plant operations is difficult, and has not been particularly successful. Problems with particulates, smoke, pollution, and flame control are encountered unless the necessary expensive control systems and operator attention are constantly available. [Pg.266]

The two liter carbon canister does not exhibit the HC release during the run loss portion of the test, nor does it release more than the allowable level of HC during the three day diumals. Thus, for the given vehicle configuration and the level of purge volume obtained by the vehicle, it is clear that a two liter carbon canister is required for this vehicle to pass the EPA certification requirement. This conclusion has an effect on the cost of the evaporative control system, in that the additional activated carbon volume and canister size will have an added cost, as will any additional hardware required to mount the larger canister on the vehicle. [Pg.259]

A vehicle fuel vapor control system must be designed to meet both driving and refueling emission level requirements. Due to the nature of hydrocarbon adsorption, this emission control is a continuous operation. [Pg.266]

Fig. 4.27 Block diagram for liquid-level process control system. Fig. 4.27 Block diagram for liquid-level process control system.
Fig. 4.28 Response of the PI controlled liquid-level system shown in Figure 4.26 to a step change in ha t) from 0 to 4 m. Fig. 4.28 Response of the PI controlled liquid-level system shown in Figure 4.26 to a step change in ha t) from 0 to 4 m.
A SOFLC is a two-level hierarchical control system that is comprised of ... [Pg.344]

Example 4.5 (Liquid-Level Process Control System)... [Pg.386]


See other pages where Level control systems is mentioned: [Pg.111]    [Pg.522]    [Pg.101]    [Pg.153]    [Pg.349]    [Pg.38]    [Pg.111]    [Pg.522]    [Pg.101]    [Pg.153]    [Pg.349]    [Pg.38]    [Pg.484]    [Pg.417]    [Pg.79]    [Pg.42]    [Pg.7]    [Pg.66]    [Pg.77]    [Pg.446]    [Pg.493]    [Pg.718]    [Pg.773]    [Pg.775]    [Pg.2225]    [Pg.2329]    [Pg.30]    [Pg.68]    [Pg.106]    [Pg.109]    [Pg.93]    [Pg.202]    [Pg.425]    [Pg.276]    [Pg.86]   