Constant potential measurement

Experimental determination of binding constants -potential measurement... [Pg.374]

Coulometric Detectors. Coulometric detectors are based on potentiostatic coulometry [30]. The signal of the constant-potential measurements, as in amperometric detection, is the current resulting from an electron-transfer process (reduction or oxidation of the analyte arriving with the eluent) while the working electrode is held at constant potential. [Pg.282]

Ampcromctry The final voltammetric technique to be considered is amperome-try, in which a constant potential is applied to the working electrode, and current is measured as a function of time. Since the potential is not scanned, amperometry does not lead to a voltammogram. [Pg.519]

A form of voltammetry in which we measure current as a function of time while maintaining a constant potential. [Pg.519]

Amperometry is a voltammetric method in which a constant potential is applied to the electrode and the resulting current is measured. Amperometry is most often used in the construction of chemical sensors that, as with potentiometric sensors, are used for the quantitative analysis of single analytes. One important example, for instance, is the Clark O2 electrode, which responds to the concentration of dissolved O2 in solutions such as blood and water. [Pg.533]

The 2eta potential (Fig. 8) is essentially the potential that can be measured at the surface of shear that forms if the sohd was to be moved relative to the surrounding ionic medium. Techniques for the measurement of the 2eta potentials of particles of various si2es are collectively known as electrokinetic potential measurement methods and include microelectrophoresis, streaming potential, sedimentation potential, and electro osmosis (19). A numerical value for 2eta potential from microelectrophoresis can be obtained to a first approximation from equation 2, where Tf = viscosity of the liquid, e = dielectric constant of the medium within the electrical double layer, = electrophoretic velocity, and E = electric field. [Pg.44]

Two methods are used to measure pH electrometric and chemical indicator (1 7). The most common is electrometric and uses the commercial pH meter with a glass electrode. This procedure is based on the measurement of the difference between the pH of an unknown or test solution and that of a standard solution. The instmment measures the emf developed between the glass electrode and a reference electrode of constant potential. The difference in emf when the electrodes are removed from the standard solution and placed in the test solution is converted to a difference in pH. Electrodes based on metal—metal oxides, eg, antimony—antimony oxide (see Antimony AND ANTIMONY ALLOYS Antimony COMPOUNDS), have also found use as pH sensors (8), especially for industrial appHcations where superior mechanical stabiUty is needed (see Sensors). However, because of the presence of the metallic element, these electrodes suffer from interferences by oxidation—reduction systems in the test solution. [Pg.464]

Reference Electrodes and Liquid Junctions. The electrical cincuit of the pH ceU is completed through a salt bridge that usually consists of a concentrated solution of potassium chloride [7447-40-7]. The solution makes contact at one end with the test solution and at the other with a reference electrode of constant potential. The Hquid junction is formed at the area of contact between the salt bridge and the test solution. The mercury—mercurous chloride electrode, the calomel electrode, provides a highly reproducible potential in the potassium chloride bridge solution and is the most widely used reference electrode. However, mercurous chloride is converted readily into mercuric ion and mercury when in contact with concentrated potassium chloride solutions above 80°C. This disproportionation reaction causes an unstable potential with calomel electrodes. Therefore, the silver—silver chloride electrode and the thallium amalgam—thallous chloride electrode often are preferred for measurements above 80°C. However, because silver chloride is relatively soluble in concentrated solutions of potassium chloride, the solution in the electrode chamber must be saturated with silver chloride. [Pg.466]

The diffusion coefficient of oxygen in solid silver was measured with a rod of silver initially containing oxygen at a conceim ation cq placed end-on in contact with a calcia-zirconia electrolyte and an Fe/FeO electrode. A constant potential was applied across dre resulting cell... [Pg.242]

Fig. 15-8 Synchronous current, voltage and potential recording with stray current interference from dc railways (a) Without protective measures, (b) direct stray current drainage to the rails, (c) rectified stray current drainage to the rails, (d) forced stray current drainage with uncontrolled protection rectifier, (e) forced stray current drainage with galvanostatically controlled protection rectifier (constant current), (f) forced stray current drainage with potentiostatically controlled protection rectifier (constant potential), (g) forced stray current drainage with potentiostatically controlled protection rectifier and superimposed constant current. Fig. 15-8 Synchronous current, voltage and potential recording with stray current interference from dc railways (a) Without protective measures, (b) direct stray current drainage to the rails, (c) rectified stray current drainage to the rails, (d) forced stray current drainage with uncontrolled protection rectifier, (e) forced stray current drainage with galvanostatically controlled protection rectifier (constant current), (f) forced stray current drainage with potentiostatically controlled protection rectifier (constant potential), (g) forced stray current drainage with potentiostatically controlled protection rectifier and superimposed constant current.
Measuring electrodes for impressed current protection are robust reference electrodes (see Section 3.2 and Table 3-1) which are permanently exposed to seawater and remain unpolarized when a small control current is taken. The otherwise usual silver-silver chloride and calomel reference electrodes are used only for checking (see Section 16.7). All reference electrodes with electrolytes and diaphragms are unsuitable as long-term electrodes for potential-controlled rectifiers. Only metal-medium electrodes which have a sufficiently constant potential can be considered as measuring electrodes. The silver-silver chloride electrode has a potential that depends on the chloride content of the water [see Eq. (2-29)]. This potential deviation can usually be tolerated [3]. The most reliable electrodes are those of pure zinc [3]. They have a constant rest potential, are slightly polarizable and in case of film formation can be regenerated by an anodic current pulse. They last at least 5 years. [Pg.408]

Aside from merely calculational difficulties, the existence of a low-temperature rate-constant limit poses a conceptual problem. In fact, one may question the actual meaning of the rate constant at r = 0, when the TST conditions listed above are not fulfilled. If the potential has a double-well shape, then quantum mechanics predicts coherent oscillations of probability between the wells, rather than the exponential decay towards equilibrium. These oscillations are associated with tunneling splitting measured spectroscopically, not with a chemical conversion. Therefore, a simple one-dimensional system has no rate constant at T = 0, unless it is a metastable potential without a bound final state. In practice, however, there are exchange chemical reactions, characterized by symmetric, or nearly symmetric double-well potentials, in which the rate constant is measured. To account for this, one has to admit the existence of some external mechanism whose role is to destroy the phase coherence. It is here that the need to introduce a heat bath arises. [Pg.20]

The simplest, and by far the most common, detection scheme is the measurement of the current at a constant potential. Such fixed-potential amperometric measurements have the advantage of being free of double-layer charging and surface-transient effects. As a result, extremely low detection limits—on the order of 1-100 pg (about 10 14 moles of analyte)—can be achieved, hi various situations, however, it may be desirable to change the potential during the detection (scan, pulse, etc.). [Pg.92]

For an ideally polarizable electrode, q has a unique value for a given set of conditions.1 For a nonpolarizable electrode, q does not have a unique value. It depends on the choice of the set of chemical potentials as independent variables1 and does not coincide with the physical charge residing at the interface. This can be easily understood if one considers that q measures the electric charge that must be supplied to the electrode as its surface area is increased by a unit at a constant potential." Clearly, with a nonpolarizable interface, only part of the charge exchanged between the phases remains localized at the interface to form the electrical double layer. [Pg.4]

As shown in Fig. 25, an example of the extrapolation of the current transient obtained from the potential sweep yields the critical potential after ascertaining that the data obtained are independent of the sweep rate. Figure 26 exhibits the results of the critical pitting potential measurement for the majority salt of NaCl and the minority ion of Ni2+when the concentration of NaCl is varied under the condition of constant Ni2+ionic concentration. From the plot in Fig. 26, it follows that... [Pg.261]

When NiCl2 is a majority salt and the Na+ ion is a minority ion, Fig. 28 indicates the critical potentials measured with changing NiCl2 concentration at constant Na+ ionic concentration... [Pg.262]

Stationary microwave electrochemical measurements can be performed like stationary photoelectrochemical measurements simultaneously with the dynamic plot of photocurrents as a function of the voltage. The reflected photoinduced microwave power is recorded. A simultaneous plot of both photocurrents and microwave conductivity makes sense because the technique allows, as we will see, the determination of interfacial rate constants, flatband potential measurements, and the determination of a variety of interfacial and solid-state parameters. The accuracy increases when the photocurrent and the microwave conductivity are simultaneously determined for the same system. As in ordinary photoelectrochemistry, many parameters (light intensity, concentration of redox systems, temperature, the rotation speed of an electrode, or the pretreatment of an electrode) may be changed to obtain additional information. [Pg.447]


See other pages where Constant potential measurement is mentioned: [Pg.86]    [Pg.98]    [Pg.347]    [Pg.131]    [Pg.86]    [Pg.374]    [Pg.118]    [Pg.129]    [Pg.86]    [Pg.98]    [Pg.347]    [Pg.131]    [Pg.86]    [Pg.374]    [Pg.118]    [Pg.129]    [Pg.113]    [Pg.182]    [Pg.533]    [Pg.769]    [Pg.466]    [Pg.141]    [Pg.244]    [Pg.404]    [Pg.448]    [Pg.93]    [Pg.409]    [Pg.840]    [Pg.113]    [Pg.260]    [Pg.123]    [Pg.234]    [Pg.124]    [Pg.246]    [Pg.1176]    [Pg.573]    [Pg.575]    [Pg.76]    [Pg.142]    [Pg.464]   