Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Conformations standard

Tested proteins (BESTP, Methods) had 28 observed TMH with 717 residues in the TMH conformation. Standard training procedure was used with each choice of amino acid attribute. Code numbers for amino acid scales are listed in Table 5... [Pg.426]

Figure 4 SEC of a mixture of synthetic peptide conformation standards. Coiumns Superdex 75 HR 10/30 (300 x 10 mm ID) and Superdex Peptide HR 10/30 (300 X 10 mm ID), both columns from Pharmacia Biotech (Bale d Urfe, Quebec, Canada). Mobile phase 50 mM aqueous KH2PO4, containing lOOmM KCl and 30% trifluoroethanol (TFE), pH 7.0 flow rate, 0.5 mL/min temperature, 25"C. The synthetic peptide mixture consisted of three peptides with the sequence Ac-(K-L-E-A-L-E-A)n-amide, where n = 1,2, 4, with 7 residues (denoted 7M, i.e., 7-residue monomer), 14 residues (denoted 14 M, i.e., 14-residue monomer), or 28 residues (denoted 28 M or 56 D, i.e., 28-residue monomer or 56-residue dimer, respectively). The bottom panel compares the resulting log g versus relationship on the two columns. The values were calculated from the expression = V 1/0/VJ - Vq, where Vg is the elution volume of the solute, Vq is the void volume of the packing (obtained from the elution time of blue dextran), and V is the accessible volume of the column (obtained from the elution time of /f-mercaptoethanol). (From Ref. 16.)... Figure 4 SEC of a mixture of synthetic peptide conformation standards. Coiumns Superdex 75 HR 10/30 (300 x 10 mm ID) and Superdex Peptide HR 10/30 (300 X 10 mm ID), both columns from Pharmacia Biotech (Bale d Urfe, Quebec, Canada). Mobile phase 50 mM aqueous KH2PO4, containing lOOmM KCl and 30% trifluoroethanol (TFE), pH 7.0 flow rate, 0.5 mL/min temperature, 25"C. The synthetic peptide mixture consisted of three peptides with the sequence Ac-(K-L-E-A-L-E-A)n-amide, where n = 1,2, 4, with 7 residues (denoted 7M, i.e., 7-residue monomer), 14 residues (denoted 14 M, i.e., 14-residue monomer), or 28 residues (denoted 28 M or 56 D, i.e., 28-residue monomer or 56-residue dimer, respectively). The bottom panel compares the resulting log g versus relationship on the two columns. The values were calculated from the expression = V 1/0/VJ - Vq, where Vg is the elution volume of the solute, Vq is the void volume of the packing (obtained from the elution time of blue dextran), and V is the accessible volume of the column (obtained from the elution time of /f-mercaptoethanol). (From Ref. 16.)...
Complying with national and European conformity standards in existence at the particular time. (This requirement does not apply to PPE obtained before the harmonising Regulations came into force, which can continue to be used v/ithout European Conformity marks, but the employer must ensure that the equipment he/she provides remains suitable for the purpose to which it is put)... [Pg.270]

Declare the conformity or non conformity of the particular flaw detector under test, in accordance with the criteria of CEN standards. [Pg.704]

Small size, ruggedness, simple cabling and the ability to operate the equipment under adverse conditions in the field has also been design goals. The system should also conform with the regulations necessary for the CE-marking (i. e. standards and directives for EMC, Electrical Safety and Machine Safety). [Pg.782]

From 1985 three major changes have been introduced to do away with the disadvantages encountered with the old approach . In 1985 the European Council adopted a New Approach to technical harmonisation and standards , in 1989 it adopted the Global Approach to conformity assessment which was amended in 1993 and in 1987 the legal basis for... [Pg.937]

NDT equipment imported in lots in the process of state testing are examined both on their conformity to the requirements of safety standards (ISO, CEN, lEC) and standards of the manufacturer and its availability for calibrartion in service. [Pg.964]

The free energy differences obtained from our constrained simulations refer to strictly specified states, defined by single points in the 14-dimensional dihedral space. Standard concepts of a molecular conformation include some region, or volume in that space, explored by thermal fluctuations around a transient equilibrium structure. To obtain the free energy differences between conformers of the unconstrained peptide, a correction for the thermodynamic state is needed. The volume of explored conformational space may be estimated from the covariance matrix of the coordinates of interest, = ((Ci [13, lOj. For each of the four selected conform-... [Pg.172]

A similar algorithm has been used to sample the equilibrium distribution [p,(r )] in the conformational optimization of a tetrapeptide[5] and atomic clusters at low temperature.[6] It was found that when g > 1 the search of conformational space was greatly enhanced over standard Metropolis Monte Carlo methods. In this form, the velocity distribution can be thought to be Maxwellian. [Pg.206]

The CIF format not only defines its dictionary of available data names, but restricts the STAR file syntax as well. For example, lines may not exceed 80 characters and data names can contain a maximum of 32 characters. Furthermore, the CIF dictionaiy specifies default units for numeric fields that represent numeric values with units. If the data item is not stored in the default units, then the units code is appended to the data name. Thus cell length a and cell length a pm represent the dimensions ofthe unit cell in Angstrom (the default units conforming to the SI Standard) and picomclcrs, respectively. [Pg.122]

There are a number of different ways that the molecular graph can be conununicated between the computer and the end-user. One common representation is the connection table, of which there are various flavours, but most provide information about the atoms present in the molecule and their connectivity. The most basic connection tables simply indicate the atomic number of each atom and which atoms form each bond others may include information about the atom hybridisation state and the bond order. Hydrogens may be included or they may be imphed. In addition, information about the atomic coordinates (for the standard two-dimensional chemical drawing or for the three-dimensional conformation) can be included. The connection table for acetic acid in one of the most popular formats, the Molecular Design mol format [Dalby et al. 1992], is shown in Figure 12.3. [Pg.659]

There are similar algorithms, also called simulated annealing, that are Monte Carlo algorithms in which the choice conformations obey a Gaussian distribution centered on the lowest-energy value found thus far. The standard deviation of this distribution decreases over the course of the simulation. [Pg.183]

Class A conforms to specifications in ASTM E694 for standard taper stopcocks and to ASTM E287 for Teflon or poly-tetrafluoroethylene stopcock plugs. The 10-mL size meets the requirements for ASTM D664. ... [Pg.1180]

The f-curve and its associated t-plot were originally devised as a means of allowing for the thickness of the adsorbed layer on the walls of the pores when calculating pore size distribution from the (Type IV) isotherm (Chapter 3). For the purpose of testing for conformity to the standard isotherm, however, a knowledge of the numerical thickness is irrelevant since the object is merely to compare the shape of the isotherm under test with that of the standard isotherm, it is not necessary to involve the number of molecular layers n/fi or even the monolayer capacity itself. [Pg.98]

Reagents conforming to standards set by the American Chemical Society. [Pg.107]

Filters for use in sterile gas filtration must conform to standards similar to those mandated for sterile hquid filtration. Nondestmctive integrity tests may be apphed. The tests are performed by wetting the filter with an appropriate solvent, commonly 60/40 isopropyl alcohol/water for hydrophobic membranes, and applying air or nitrogen gas at a preset pressure. [Pg.142]

The pubHcations detailing standards (5—8) generally include both specifications and methods of analysis for the substances. The estabHshment of standards of quaHty for chemicals of any kind presupposes the abiHty to set numerical limits on physical properties, allowable impurities, and strength, and to provide the test methods by which conformity to the requirements may be demonstrated. Tests are considered appHcable only to the specific requirements for which they were written. Modification of a requirement, especially if the change is toward a higher level of purity, often necessitates revision of the test to ensure the test s vaHdity. [Pg.444]

Both equation 11 and the two-dimensional counterpart of equation 9 can be solved by several standard mathematical techniques, one of the more useful being that of conformal mapping. A numerical solution is often more practical for compHcated configurations. [Pg.89]


See other pages where Conformations standard is mentioned: [Pg.372]    [Pg.281]    [Pg.300]    [Pg.269]    [Pg.98]    [Pg.372]    [Pg.281]    [Pg.300]    [Pg.269]    [Pg.98]    [Pg.938]    [Pg.943]    [Pg.964]    [Pg.132]    [Pg.166]    [Pg.171]    [Pg.173]    [Pg.189]    [Pg.102]    [Pg.209]    [Pg.446]    [Pg.503]    [Pg.533]    [Pg.536]    [Pg.669]    [Pg.207]    [Pg.210]    [Pg.285]    [Pg.107]    [Pg.180]    [Pg.777]    [Pg.140]    [Pg.167]    [Pg.329]    [Pg.98]    [Pg.98]   
See also in sourсe #XX -- [ Pg.37 ]




SEARCH



Conformance to this International Standard

Conformance with standards

Harmonized Standards Presumption of Conformity

Peptide standards conformation

Standard high-energy conformations

Use of Standards to Establish Conformity

© 2024 chempedia.info