Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Coded units

Thus, in modem research using interval and ratio scales the 5x usually shouldn t be ignored. Let s add 8x, to the calculation to obtain b, as would be done with regression analysis. Because Xj went from a coded level of -1 to a coded level of -t-1, 5x, = 2. Thus, b (the factor effect in the coded factor space) = 8y,/8xJ = -i-3.6% per 2 coded units = -i-1.8% per coded unit. The fact that 8x is equal to 2 with this system of coding is why regression analysis of coded data gives results that are smaller by Vi from the results obtained from the classical approach ... [Pg.326]

Harwell Laboratory. Ceneral-purpose Computational Fluid Dynamics (CFD) Code. United Kingdom, Harwell Laboratory. [Pg.435]

Protein synthesis means translation into a peptide chain of a genetic message first copied (transcribed) into m-RNA (p. 274). Amino acid (AA) assembly occurs at the ribosome. Delivery of amino acids to m-RNA involves different transfer RNA molecules (t-RNA), each of which binds a specific AA. Each t-RNA bears an anticodon nucleobase triplet that is complementary to a particular m-RNA coding unit (codon, consisting of 3 nucleobases. [Pg.276]

Coding Units Building Blocks Chemical Reactions... [Pg.275]

Genetic Information in E. Coli DNA The genetic information contained in DNA consists of a linear sequence of coding units, known as codons. Each codon is a specific sequence of three deoxyri-bonucleotides (three deoxyribonucleotide pairs in double-stranded DNA), and each codon codes for a single amino acid unit in a protein. The molecular weight of an E. coli DNA molecule is about... [Pg.3]

Practically, chemical concentrations are reported in different units. For the conversion between the most common units and the GF3 code units, a list of conversion factors is given in Table 20.5, based on most recent reference data(lUPAC, 2005 ICES, 2006 IOC, 2006). [Pg.633]

The 11-run design and resulting data are listed in Table 9. The first four runs are the imbedded 2 factorial points, the next four runs are the axial or star points, and the last three runs are the center points. The factor levels are listed in the actual units ( uncoded form) and in coded units. The value of a was set to 1 to minimize the number of factor levels required, instead of conducting a rotatable design... [Pg.153]

Estimated regression coefGcients for yield coded units ... [Pg.158]


See other pages where Coded units is mentioned: [Pg.236]    [Pg.123]    [Pg.5]    [Pg.448]    [Pg.89]    [Pg.260]    [Pg.328]    [Pg.328]    [Pg.41]    [Pg.212]    [Pg.275]    [Pg.276]    [Pg.276]    [Pg.276]    [Pg.11]    [Pg.461]    [Pg.664]    [Pg.667]    [Pg.678]    [Pg.679]    [Pg.685]    [Pg.61]    [Pg.15]    [Pg.210]    [Pg.221]    [Pg.4]    [Pg.14]    [Pg.387]    [Pg.337]    [Pg.1434]    [Pg.629]    [Pg.66]    [Pg.77]    [Pg.77]    [Pg.83]    [Pg.157]    [Pg.163]   
See also in sourсe #XX -- [ Pg.3 ]




SEARCH



Design Code units

Parameters Codes, Units, and Conversions

United States Code

United States Code of Federal Regulations

United States Code of Federal Regulations sections

© 2024 chempedia.info