Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Columner phase

In practice, however, the liquid velocity relative to fixed particles, Uf, is not very useful. Instead, the velocity of settling relative to the walls of an apparatus, Uf - u, is of practical importance. The volume of the solid phase moving downward should be equal to that of liquid moving upward. This means that volume rates of these phases must be equal. Consider a column of slurry having a unit cross section and imagine the liquid and solid phases to have a well defined interface. The column of solid phase will have a base 1 - e, and the liquid column phase will have a base e. Hence, the volumetric rate of the solid column will be (1 - e)u, and that of the liquid column will be (Uf - u)e. Because these flowrates are equal to each other, we obtain... [Pg.287]

Figure 4.7 The selective or targeted mode of LMCS operation allows selected peaks to be collected sequentially in the cryoti ap, and then pulsed rapidly to the second column. The resulting peaks are naixow and tall provided that the second column phase selectivity and efficiency are adequate, they will also be resolved. The process is repeated as many times as required during the analysis. On this diagram, the lower ti ace response scale will be considerably less sensitive than on the upper ti ace. Figure 4.7 The selective or targeted mode of LMCS operation allows selected peaks to be collected sequentially in the cryoti ap, and then pulsed rapidly to the second column. The resulting peaks are naixow and tall provided that the second column phase selectivity and efficiency are adequate, they will also be resolved. The process is repeated as many times as required during the analysis. On this diagram, the lower ti ace response scale will be considerably less sensitive than on the upper ti ace.
The moving-drop method [2] employs a column of one liquid phase through which drops of a second liquid either rise or fall. The drops are produced at a nozzle situated at one end of the column and collected at the other end. The contact time and size of the drop are measurable. Three regimes of mass transport need to be considered drop formation, free rise (or fall) and drop coalescence. The solution in the liquid column phase or drop phase (after contact) may be analyzed to determine the total mass transferred, which may be related to the interfacial reaction only after mass transfer rates have been determined. [Pg.342]

Using the retention data and the chromatogram shown in Fig. 14.8, tabulate the following for each peak retention time ( r), adjusted retention time (t K), retention factor (k), partition coefficient (Kc) and number of theoretical plates (N). The column phase ratio was 250 and the gas hold up time ( m) was 0.995 min. [Pg.488]

Axelman, J. Ntes, K. Naf, C. Broman, D. 1999, Accumulation of polycyclic aromatic hydrocarbons in semipermeable membrane devices and caged mussels (Mvtilus edulisl in relation to water column phase distribution. Environ. Toxicol. Chem. 18 2454-2461. [Pg.24]

AG°s is the standard free energy of adsorption of the solute to the stationary phase surface ([) is the column phase ratio... [Pg.426]

Fused copper porphyrin dimers (compounds 156 and 177, see Figs. 42 and 47) with an orthorhombic phase and a rectangular column phase, respectively, were recently reported by Aida et al. [277]. Interestingly, the partly RF-substituted... [Pg.59]

Here also lies one major difference between a sensor array and a separation experiment. In the latter, the advancing front of the already separated sample always encounters the pristine stationary column phase and interacts accordingly, whereas in a chemical sensor array all components of the sample interact with the sensing layers at once. The direct sensing and the separation experiments are not directly comparable but are complementary. In summary, increasing the order of the sensor... [Pg.317]

Sample Analytes Sample Preparation Column Phase Detection LOD Ref. [Pg.48]

As shown in Figure 32, the sector column phase can also be considered as the distortion of the vertical lamellae phase in the flat plates system, which is a counterpart to the above parallel lamellae. With the assumption of the repeated number of basic A-B unit in the cylinder, and the interval angle of basic unit, 6 = 2jt/M, M is the number of sectors, the interfacial contribution per copolymer chain can be expressed as ... [Pg.198]

Similar to the abovementioned method, the entropic contribution of single chain of sector column phase can be written as... [Pg.198]

XN = 30, and N = 20). Lines 1-3 concentric cylinder barrel phase at K= 0.01,0.02, and 0.03, respectively lines 4-6 sector column phase at K = 0.01, 0.02, and 0.03, respectively lines 7-9 complex multilayered sector column phase at K = 0.01, 0.02, and 0.03, respectively, (b) A sketch of morphology transition for a set of competing structures between the concentric cylinder barrel phase and the sector column phase in part (a), where sec means the sector column phase, and conVj means the concentric cylinder barrel structure with N ayer = n. [Pg.205]

When both the exterior and interior surfaces of the confined cylinder are neutral, the second term in Equation (69) equals to zero. If the exterior radius Fex is fixed, Fcmsc is only a function of d. Fsquare(Rex) is the Helmholtz energy of concentric square column phase. [Pg.207]

Fig. 27 A series of AFM height (left column) phase (right column) images of the growth front of a spherulite of BA-C8 in a consecutive time sequence [60]... Fig. 27 A series of AFM height (left column) phase (right column) images of the growth front of a spherulite of BA-C8 in a consecutive time sequence [60]...
To classify a separation technique by LC into these two types, it should be clear whether the sample copolymers adsorb on the surface of the stationary phase or precipitate on the top of the column (phase separation) when the sample copolymers are injected into a column. If the separation mechanism is not clearly understood or when the separation by the solubility difference of the sample copolymers between the stationary and the mobile phases can be considered, then the technique can be classified into normal-phase and reversed-phase chromatography as the third type (Table III). Initial and final mobile phases should be good solvents for the sample copolymers. The initial mobile phases in Table III are 15% THF in acetonitrile (AcCN) or 10% THF in cyclohexane (J5), 35% THF in n-hexane (J6), 20% CH2CI2 in AcCN (J7), and 10% CHCI3 in n-hexane (18). The final mobile phases are 65% THF in AcCN or 60% THF in cyclohexane (15), 85% THF in n-hexane (J6), 80% CH2CI2 in AcCN (17), and 40% CHCI3 in n-hexane (J8). [Pg.214]

A more sophisticated method of comparing retention times, and one that is applicable across different column phases and temperature programs, is by way of retention time indices or Kovat s indices (KIs).129 The KI for a particular analyte is calculated against a homologous series of -alkanes, coinjected with the sample. [Pg.362]

Initially packed columns were used, but capillary columns are most frequently used today. A variety of polar and non-polar column phases have been used to determine VOCs depending on the particular compound(s) analyzed. Numerous examples were summarized by Wille and Lambert.5 Similarly, a range of detection devices have been utilized. Flame ionization detection (FID) and mass spectrometry (MS) in the selected-ion monitoring mode (SIM) are most frequently used, but other techniques include electron-capture detection (ECD) and Fourier transform infrared (FTIR) detection. [Pg.130]


See other pages where Columner phase is mentioned: [Pg.76]    [Pg.96]    [Pg.47]    [Pg.220]    [Pg.1227]    [Pg.373]    [Pg.70]    [Pg.453]    [Pg.463]    [Pg.397]    [Pg.442]    [Pg.444]    [Pg.693]    [Pg.1227]    [Pg.96]    [Pg.62]    [Pg.93]    [Pg.187]    [Pg.199]    [Pg.204]    [Pg.205]    [Pg.205]    [Pg.206]    [Pg.206]    [Pg.209]    [Pg.290]    [Pg.162]    [Pg.379]   
See also in sourсe #XX -- [ Pg.4 ]




SEARCH



© 2024 chempedia.info