Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Collecting tank

A typical ozone system consists of 100 g/hr at a concentration of 1.0 percent to 1.5 percent in air fed to the bottom of bleach collection tanks through ceramic spargers (pore size of approximately 100 t). The system contains air compression and drying equipment, automatic control features, and a flat-plate, air-cooled ozone generator. Regeneration of bleach wastes totaling about 10,000 gallons a year, and recovery of other chemicals can also be cost effective. [Pg.490]

A device called an air washer is also used for humidification and dehumidification, It consists of a chamber incorporating a water spray system, a collection tank, and an eliminator section. The eliminator plates are necessary to reduce the incidence of water droplets that are carried out of the plant into the duct run. [Pg.721]

PW circulation pumps B/A mechanical failure PW circulation pumps B/A stopped by operator PW collecting tanks pmnps B/A failure PW flow switch failure PW supply pumps B/A controller 2 failure PW supply pumps B/A mechanical failure PW supply pumps B/A stopped by operator PW surge tank instrument failure -15 C glycol storage tank leak PW level valve fails... [Pg.622]

Condensate from the low-pressure coil together with that from the flash vessel will then drain to a collecting tank, or direct to a condensate pump, for return to the boiler plant. If the pressure of the flash steam is left to find its own level it will often be sub-atmospheric. As the condensate must then drain by gravity through the steam traps these also must be sufficiently below the condensate drain points to provide an appropriate hydraulic head, and a vacuum breaker fitted above the coil. The alternatives are to allow the condensate to drain directly to a condensate pump, or to supply additional low-pressure steam through a pressure-reducing valve, to maintain a positive pressure in the coil and flash vessel. [Pg.327]

Cooling towers and evaporative condensers may freeze in winter if left operating on a light load. A common arrangement is to switch off the fan(s) with a thermostat, to prevent the formation of ice. The water-collection tank will have an immersion heater to reduce... [Pg.71]

The atmospheric condenser is a simplified form of evaporative condenser, having plain tubes over a collecting tank and relying only on natural air draught. This will be located on an open roof or large open space to ensure a good flow of air. The space required is of the order of 0.2 m /kW, and such condensers are not much used because of this large space requirement. Atmospheric condensers can still be seen on the roofs of old breweries. They are in current use where space is plentiful. [Pg.72]

I. Baudelot coolers (see Figures 7.7 and 7.8a). The evaporator stands above a collection tank, and the water runs down the outside surface in a thin layer. Evaporator construction can be pipe coils or embossed plates. The latter are now usually of stainless steel, to avoid corrosion troubles. Evaporators maybe flooded or dry expansion. During operation, a Baudelot cooler... [Pg.145]

Other typical uses of titanium in a membrane cell process are in the pipelines for hot anolyte and in the anolyte collecting tanks as well as dechlorination systems that normally work under vacuum and sometimes limit the use of loose linings. [Pg.305]

This scheme will be more expensive than a central collection tank for all... [Pg.67]

In continuously working units cooled hydroxide solution enters at the bottom of the chlorinators which are provided with cooling coils a measured amount of chlorine is simultaneously admitted. The hypochlorite solution leaves the vessels through the overflow, and flows through a stoneware coil, which is externally cooled by water, into a collecting tank with a rubber coated stirrer and a PVC water cooler. The composition of the liquor is here adjusted by the addition of hydroxide or chlorine, and the finished hypochlorite solution is then stored. [Pg.345]

In addition to the large waste collection tank/ the column effluent liquid can be routed to either of five product collection tanks, each of which has a capacity of 7 L. [Pg.152]

Thanks to environmental concerns of industrialized populations and due to the always increasing price of tap water, rainwater collecting tanks become more and more popular to collect free water in order to use it for all domestic uses except drinking water (toilets, showers, washing machines, etc.). Installation scheme of such system is shown in Fig. 6.11. [Pg.156]

Labeling Where the gas is piped from cylinders or directly from the collecting tank to the point of use, label each outlet Nitrogen Enriched Air. ... [Pg.304]

Packaging and Storage Store in metal cylinders or in a low-pressure collecting tank. [Pg.305]

Because of the unusual amount of dust deposited and because the dust came from an area that has received heavy annual treatment with pesticides for many years, a large sample was collected for analysis at an installation that had previously been used to collect rainfall. Essentially, the collection surface is one fourth of a galvanized iron roof with the gutter arranged to discharge roof runoff into a collection tank. The collection area is 1090 square feet calculated from a horizontal projection. The day after the storm, the roof surface was flushed with 110 liters of Cincinnati tap water, and the dust slurry was collected in a stainless steel tank. The roof surface had been cleansed before the dust was de-... [Pg.176]


See other pages where Collecting tank is mentioned: [Pg.494]    [Pg.423]    [Pg.296]    [Pg.224]    [Pg.224]    [Pg.225]    [Pg.378]    [Pg.69]    [Pg.87]    [Pg.1160]    [Pg.1327]    [Pg.84]    [Pg.440]    [Pg.177]    [Pg.13]    [Pg.97]    [Pg.95]    [Pg.423]    [Pg.53]    [Pg.296]    [Pg.364]    [Pg.143]    [Pg.30]    [Pg.274]    [Pg.142]    [Pg.295]    [Pg.150]    [Pg.154]    [Pg.584]    [Pg.494]    [Pg.629]    [Pg.632]    [Pg.633]    [Pg.640]   
See also in sourсe #XX -- [ Pg.30 ]




SEARCH



Collection Tank and pH Adjustment

Collection tank

Oil collection tank

© 2024 chempedia.info