Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Characterization electron spectroscopy

Time-of-flight mass spectrometers have been used as detectors in a wider variety of experiments tlian any other mass spectrometer. This is especially true of spectroscopic applications, many of which are discussed in this encyclopedia. Unlike the other instruments described in this chapter, the TOP mass spectrometer is usually used for one purpose, to acquire the mass spectrum of a compound. They caimot generally be used for the kinds of ion-molecule chemistry discussed in this chapter, or structural characterization experiments such as collision-induced dissociation. Plowever, they are easily used as detectors for spectroscopic applications such as multi-photoionization (for the spectroscopy of molecular excited states) [38], zero kinetic energy electron spectroscopy [39] (ZEKE, for the precise measurement of ionization energies) and comcidence measurements (such as photoelectron-photoion coincidence spectroscopy [40] for the measurement of ion fragmentation breakdown diagrams). [Pg.1354]

Instrumental Methods for Bulk Samples. With bulk fiber samples, or samples of materials containing significant amounts of asbestos fibers, a number of other instmmental analytical methods can be used for the identification of asbestos fibers. In principle, any instmmental method that enables the elemental characterization of minerals can be used to identify a particular type of asbestos fiber. Among such methods, x-ray fluorescence (xrf) and x-ray photo-electron spectroscopy (xps) offer convenient identification methods, usually from the ratio of the various metal cations to the siUcon content. The x-ray diffraction technique (xrd) also offers a powerfiil means of identifying the various types of asbestos fibers, as well as the nature of other minerals associated with the fibers (9). [Pg.352]

Laser ionization mass spectrometry or laser microprobing (LIMS) is a microanalyt-ical technique used to rapidly characterize the elemental and, sometimes, molecular composition of materials. It is based on the ability of short high-power laser pulses (-10 ns) to produce ions from solids. The ions formed in these brief pulses are analyzed using a time-of-flight mass spectrometer. The quasi-simultaneous collection of all ion masses allows the survey analysis of unknown materials. The main applications of LIMS are in failure analysis, where chemical differences between a contaminated sample and a control need to be rapidly assessed. The ability to focus the laser beam to a diameter of approximately 1 mm permits the application of this technique to the characterization of small features, for example, in integrated circuits. The LIMS detection limits for many elements are close to 10 at/cm, which makes this technique considerably more sensitive than other survey microan-alytical techniques, such as Auger Electron Spectroscopy (AES) or Electron Probe Microanalysis (EPMA). Additionally, LIMS can be used to analyze insulating sam-... [Pg.586]

Methane-to-methanol conversion by gas-phase transition metal oxide cations has been extensively studied by experiment and theory see reviews by Schroder, Schwarz, and co-workers [18, 23, 134, 135] and by Metz [25, 136]. We have used photofragment spectroscopy to study the electronic spectroscopy of FeO" " [47, 137], NiO [25], and PtO [68], as well as the electronic and vibrational spectroscopy of intermediates of the FeO - - CH4 reaction. [45, 136] We have also used photoionization of FeO to characterize low lying, low spin electronic states of FeO [39]. Our results on the iron-containing molecules are presented in this section. [Pg.345]

We have undertaken a series of experiments Involving thin film models of such powdered transition metal catalysts (13,14). In this paper we present a brief review of the results we have obtained to date Involving platinum and rhodium deposited on thin films of tltanla, the latter prepared by oxidation of a tltanliua single crystal. These systems are prepared and characterized under well-controlled conditions. We have used thermal desorption spectroscopy (TDS), Auger electron spectroscopy (AES) and static secondary Ion mass spectrometry (SSIMS). Our results Illustrate the power of SSIMS In understanding the processes that take place during thermal treatment of these thin films. Thermal desorption spectroscopy Is used to characterize the adsorption and desorption of small molecules, In particular, carbon monoxide. AES confirms the SSIMS results and was used to verify the surface cleanliness of the films as they were prepared. [Pg.81]

Surface and bulk characterization were carried out using electron spectroscopy for chemical analysis (ESCA or XPS) and x-ray diffraction (XRB). The results will be discussed In relation to methanatlon activity. [Pg.306]

Size reduction of metal particles results in several changes of the physico-chemical properties. The primary change is observed in the electronic properties of the metal particles which can be characterized by ultraviolet and X-ray photoelectron spectroscopy (UPS and XPS, respectively) as well as Auger-electron spectroscopy (AES) measurements. Furthermore, morphology of the metal nanoparticles is highly sensitive to the environment, such as ion-metal interaction (e.g. metal-support interaction)... [Pg.77]

The effects of tin/palladium ratio, temperatnre, pressnre, and recycling were studied and correlated with catalyst characterization. The catalysts were characterized by chemisorption titrations, in situ X-Ray Diffraction (XRD), and Electron Spectroscopy for Chemical Analysis (ESCA). Chemisorption studies with hydrogen sulfide show lack of adsorption at higher Sn/Pd ratios. Carbon monoxide chemisorption indicates an increase in adsorption with increasing palladium concentration. One form of palladium is transformed to a new phase at 140°C by measurement of in situ variable temperature XRD. ESCA studies of the catalysts show that the presence of tin concentration increases the surface palladium concentration. ESCA data also indicates that recycled catalysts show no palladium sulfide formation at the surface but palladium cyanide is present. [Pg.135]

The preparation of ZnSe materials is an area of interest and study. The coordinating ability of the solvent used in the solvothermal synthesis of zinc selenide was demonstrated to play an important role in the nucleation and growth of nanocrystalline ZnSe.604 Thermolysis of bis [methyl( -hexyl)di-seleno]carbamato]zinc gave highly monodispersed particles characterized by electronic spectroscopy, photoluminescence, X-ray diffraction, and electron microscopy.605... [Pg.1199]

Migowski, P., Teixeira, S.R., Machado, G., Alves, M.C.M., Geshev, J. and Dupont, J. (2007) Structural and magnetic characterization of Ni nanopartides synthesized in ionic liquids. Journal of Electron Spectroscopy and Related Phenomena, 156, 195—199. [Pg.83]

The characterization of evaporated alloy films can be carried out at widely different levels of sophistication. At the very least, it is necessary to determine the bulk composition, probably after the film has been used for an adsorption or catalytic experiment. Then various techniques can be applied, e.g., X-ray diffraction, electron diffraction, and electron microscopy, to investigate the homogeneity or morphology of the film. The measurement of surface area by chemisorption presents special problems compared with the pure metals. Finally, there is the question of the surface composition (as distinct from the bulk or overall composition), and a brief account is given of techniques such as Auger electron spectroscopy which might be applied to alloy films. [Pg.134]

There is now available a substantial amount of information on the principles and techniques involved in preparing evaporated alloy films suitable for adsorption or catalytic work, although some preparative methods, e.g., vapor quenching, used in other research fields have not yet been adopted. Alloy films have been characterized with respect to bulk properties, e.g., uniformity of composition, phase separation, crystallite orientation, and surface areas have been measured. Direct quantitative measurements of surface composition have not been made on alloy films prepared for catalytic studies, but techniques, e.g., Auger electron spectroscopy, are available. [Pg.184]

Hooker, M. P., and Grant, J. T. 1977. The use of Auger electron spectroscopy to characterize the adsorption of carbon monoxide transition metals. Surf. Sci. 62 21-30. [Pg.78]

Due to the opaque nature of most solids, investigations that use some type of electronic spectroscopy as a means of characterization cannot be performed in the transmission mode. Studies performed in the solid state therefore must make... [Pg.37]

Polymer films were produced by surface catalysis on clean Ni(100) and Ni(lll) single crystals in a standard UHV vacuum system H2.131. The surfaces were atomically clean as determined from low energy electron diffraction (LEED) and Auger electron spectroscopy (AES). Monomer was adsorbed on the nickel surfaces circa 150 K and reaction was induced by raising the temperature. Surface species were characterized by temperature programmed reaction (TPR), reflection infrared spectroscopy, and AES. Molecular orientations were inferred from the surface dipole selection rule of reflection infrared spectroscopy. The selection rule indicates that only molecular vibrations with a dynamic dipole normal to the surface will be infrared active [14.], thus for aromatic molecules the absence of a C=C stretch or a ring vibration mode indicates the ring must be parallel the surface. [Pg.84]

The elemental composition, oxidation state, and coordination environment of species on surfaces can be determined by X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES) techniques. Both techniques have a penetration depth of 5-20 atomic layers. Especially XPS is commonly used in characterization of electrocatalysts. One common example is the identification and quantification of surface functional groups such as nitrogen species found on carbon-based catalysts.26-29 Secondary Ion Mass spectrometry (SIMS) and Ion Scattering Spectroscopy are alternatives which are more surface sensitive. They can provide information about the surface composition as well as the chemical bonding information from molecular clusters and have been used in characterization of cathode electrodes.30,31 They can also be used for depth profiling purposes. The quantification of the information, however, is rather difficult.32... [Pg.339]


See other pages where Characterization electron spectroscopy is mentioned: [Pg.938]    [Pg.1385]    [Pg.1851]    [Pg.2938]    [Pg.177]    [Pg.24]    [Pg.954]    [Pg.57]    [Pg.570]    [Pg.171]    [Pg.185]    [Pg.285]    [Pg.48]    [Pg.334]    [Pg.342]    [Pg.347]    [Pg.367]    [Pg.157]    [Pg.80]    [Pg.423]    [Pg.348]    [Pg.253]    [Pg.259]    [Pg.486]    [Pg.1217]    [Pg.676]    [Pg.130]    [Pg.349]    [Pg.3]    [Pg.487]    [Pg.44]    [Pg.98]    [Pg.121]   
See also in sourсe #XX -- [ Pg.513 , Pg.514 ]




SEARCH



Auger electron spectroscopy surface characterization

Electron characterization

Electron energy loss spectroscopy catalyst characterization

Electronic Characterization

Electronic characterization techniques photoelectron spectroscopy

Electronic characterization techniques valence excitation spectroscopy

Spectroscopy characterization

© 2024 chempedia.info