Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Certifications multiple

Edcfy-cufrent NDT inspections using spatial data (sampled scans) ha >e many benefits. They separate the two conflicting aspects of an inspection scanning and signal interpretation. An instrument/display (client/server) based NDT inspection based on sampled scan data aides in the training and certification of inspectors. It can be used over the Internet or in-house Intranet networks to train or examine inspectors at multiple or remote sites. This saves travel time and resources as defects, instrumentation and teaching can all be consolidated Samples can be maintained and distributed from a central certification body providing more control andflexibility. [Pg.1014]

Examples of approaches followed by a small selection of the major RM developers are provided below and summarized in Table 3.2. It must be emphasized that these assignments are based on the author s interpretation of approaches described in the literature that placing into one of the approaches defined in this paper is not always feasible due to cross-over between different modes, fusion of ideas from one and another, elimination of steps, selective choices of parameters, modification of parameters, and streamlining of the overall procedure. Variations on a theme are unavoidable. In assigning certification approaches, the numbers refer to the approaches defined above multiple numbers indicate a blending of two or more modes with a asterisk indicating the author s assignment of the dominant mode of certification. [Pg.58]

There are many similarities in the certification approaches used by NIST and BCR as well as major differences. Both the NIST and BCR approaches are based on results from multiple independent methods. For the NIST SRMs the measurements are generally all performed at NIST with emphasis on the independence of the methods, whereas the BCR relies on results from a large number of laboratories that may use different methods. The certification approaches used by NIST and BCR are described below using as an example the measurement of PAHs in an environmental matrix. [Pg.88]

BCR Analytical Approach for the Certification of PAHs in Natural Matrix CRMs Prior to the certification analyses for the CRM, each participating laboratory has to prepare standard solutions of the analytes to be determined from certified reference compounds (purity >99.0 %) to calibrate their instruments for response and response linearity (multiple point calibration), detection limit, and reproducibility. In the case of PAH measurements, reference compounds of certified purity are used as internal standards, which are not present at a detectable concentration in the matrix to be analyzed (e.g. indeno[i,2,3-cd]fluoranthene (CRM 267), 5-methylchrysene (CRM 081R), benzo[f ]chry-sene (CRM 046), picene (CRM 168), and/or phenanthrene-dio). [Pg.99]

Identification of dyes on dyed textiles is traditionally carried out by destructive techniques [493], TLC is an outstanding technique for identification of extracted dyestuffs and examination of inks. Figure 4.9 shows HPTLC/SERRS analysis of acridine orange [492], Wright et al. [494] have described a simple and rapid TLC-videodensitometric method for in situ quantification of lower halogenated subsidiary colours (LHSC) in multiple dye samples. The results obtained by this method were compared with those obtained by an indirect TLC-spectrophotometric method and those from HPLC. The total time for the TLC-videodensitometric assay of five standards and four samples applied to each plate was less than 45 min. The method is applicable for use in routine batch-certification analysis. Loger et al. [495,496] have chromatographed 19 basic dyes for PAN fibres on alumina on thin-layer with ethanol-water (5 2) and another 11 dyes on silica gel G with pyridine-water... [Pg.229]

Car number 42 is the first car to get both coupon and gift certificate. This is the least common multiple of 6 and 14. [Pg.254]

Multiple 30-month stays prevented FDA approval of the generie applicants AND As for 4 to 40 months beyond the initial 30-month period. FDA approval may have occurred more quickly in the absence of the multiple 30-month stays, because the data indicate that FDA approval has occurred, on average, within 25 months and 15 days for generic applicants with paragraph IV certifications that were not sued. [Pg.6]

The initial 30-month stay is not dependent upon the number of patents for which a paragraph IV certification is made. Whether a generic applicant makes an initial paragraph IV certification with respect to one patent, or to multiple patents, only one 30-month stay will be invoked. [Pg.58]

An interesting approach is the application of multiple ion collector mass spectrometry (MC-TIMS and MC-ICP-MS) for the determination of Cd and T1 in high purity zinc metal after trace matrix separation by the certification of reference materials from the Bureau Communie de Reference (BCR).29 Accurate and precise element concentrations in high purity zinc metal have been obtained with both mass spectrometric techniques via precise isotope ratio measurements using the isotope dilution strategy the analytical data. [Pg.265]

Unlike the IFOAM accreditation program, government-run conformity assessment systems mainly operate at a national level, with no multilateral arrangements in place to facilitate trade of organically certified products recognised by one country into a second country. This has led to a situation in which a certification body operating in one country needs to obtain accreditation after accreditation to enable the products that it certifies to enter into multiple markets as organic. [Pg.205]

Advance funeral arrangements You have the freedom to make all your own arrangements. Make sure you communicate them, providing all necessary details. Include a reminder that the funeral director provide multiple copies of the death certificate for processing insurance and Social Security claims. [Pg.255]

To satisfactorily meet and address these regulatory and market needs, standard methods for emissions testing need to be both robust and repeatable for competent laboratories to carry out, and practical and affordable for manufacturing industry. Uniformity of test methods, between countries and markets is also important if manufacturers are to avoid having to submit the same products for emissions testing by multiple different emissions certification protocols. [Pg.120]

Although Dan had been diagnosed with MCS, this was not reported in his official death certificate. His death is officially the result of a neuromuscular degeneration (a disease that damages the nervous system and muscles). No autopsy was performed, www.ridefor life.com/news/als news/multiple chemical sensitivity and als.html... [Pg.117]

Note Many chemistry essays on certification exams consist of quantitative problem solving with the requirement to show your work. The first of the two sample essays is of this type. For additional practice, I recommend solving quantitative problems from the multiple choice sample test with an essay mindset and comparing your essays to the solutions shown in the Answers with Solutions section. Some chemistry essays require little or no quantitative problem solving, but they ask for an experimental design or analysis of a design. The second of the two sample essays is of this type. These essays usually have no single correct solution. [Pg.336]

Regarding production of bulk drug substances, specifications for contaminants should be established for all solvents used in the process. A comparison should be performed between the manufacturer s Certificate of Analysis and the submitted specifications, and any discrepancies should be justified. A full description for the route of synthesis should be given, as this is important for the testing and control of impurities and process solvent residues. The FDA expects that, at the time of submission, it will be determined if the drug substance exists in a multiple solid state form (racemic mixture stereoisomer) and whether this affects the dissolution and bioavailability of the drug product. [Pg.340]

Organic bread sold through in-store bakeries within supermarkets is rarely if ever produced on the premises. When the EU Regulation became law in 1991 the multiples opted not to seek certification for scratch baking in their in-store bakeries. Although justified at the time on grounds of cost - 300 to license a production unit - the more likely reason (apart... [Pg.136]

Multiple overlapping, prospective methods of case ascertainment used to identify all individuals with condition of interest from a predefined population includes searches of both primary and secondary care and databases of diagnostic tests and death certification/mortality statistics... [Pg.6]


See other pages where Certifications multiple is mentioned: [Pg.91]    [Pg.351]    [Pg.249]    [Pg.40]    [Pg.57]    [Pg.63]    [Pg.91]    [Pg.115]    [Pg.48]    [Pg.5]    [Pg.57]    [Pg.60]    [Pg.259]    [Pg.16]    [Pg.214]    [Pg.214]    [Pg.421]    [Pg.91]    [Pg.131]    [Pg.162]    [Pg.164]    [Pg.509]    [Pg.53]    [Pg.406]    [Pg.45]    [Pg.42]    [Pg.73]    [Pg.92]    [Pg.196]    [Pg.91]    [Pg.351]    [Pg.1668]    [Pg.111]   
See also in sourсe #XX -- [ Pg.335 ]

See also in sourсe #XX -- [ Pg.335 ]




SEARCH



Certificate

Certification

© 2024 chempedia.info