Cathodic first pulses

Tunable electrodes will be the way of the future. Using electrodes with multiple contacts through which electric fields in the tissue space can be shaped will enable purveyors of neural prostheses to electronically adjust or improve the efficacy without physically moving the electrode relative to the target tissue. These techniques, field steering, will likely utilize both anodic and cathodic first pulse paradigms. [Pg.1354]

An important feature of all gas ionization detectors is their dead or paralysis time, which has a direct bearing on their utility. Once initiated a voltage pulse takes several hundred microseconds to die away, and may be prolonged by the discharge of secondary electrons from the cathode as the argon ions are reduced. Until this first pulse is terminated the tube is dead to further radiations and the recorded count CM will be less than the true count CT. The relation between the two values will depend upon the length of the dead time t... [Pg.459]

Pulsed-current techniques can furnish electrochemical kinetic information and have been used at the RDE. With a pulse duration of 10-4 s and a cycle time of 10-3 s, good agreement was found with steady-state results [144] for the kinetic determination of the ferri-ferrocyanide system [260, 261], Reduction of the pulse duration and cycle time would allow the measurement of larger rate constants. Kinetic parameter extraction has also been discussed for first-order irreversible reactions with two-step cathodic current pulses [262], A generalised theory describing the effect of pulsed current electrolysis on current—potential relations has appeared [263],... [Pg.429]

Smith-Hieftje background correction uses a single hollow-cathode lamp pulsed with first a low current and then a high current. The low-current mode obtains the total absorbance, while the background is estimated during the high-current pulse. Read the interview at the beginning of Part V to learn more about Cary Hieftje and his work. [Pg.862]

If irreversible processes do occur, for cathodic first charge-balanced biphasic pulsing, the electrode potential will move positive of the open-circuit potential, and during steady-state continuous pulsing there is an equal amount of unrecoverable charge delivered into cathodic- and anodic-irreversible processes. [Pg.110]

Fig. 16 Current and voltage waveforms of a PEDOT-coated Pt electrode under pulse stimulation (a). The electrode was stimulated in PBS under a charge-balanced, cathodic-first, biphasic pulse current at 1 mC/cm at 50 Hz (b). Voltage excursion was measured under pulse stimulation currents to evaluate the PEDOT electrode charge injection capacity... Fig. 16 Current and voltage waveforms of a PEDOT-coated Pt electrode under pulse stimulation (a). The electrode was stimulated in PBS under a charge-balanced, cathodic-first, biphasic pulse current at 1 mC/cm at 50 Hz (b). Voltage excursion was measured under pulse stimulation currents to evaluate the PEDOT electrode charge injection capacity...
Fig. 2.2 (a) Directly measured electrode potential, (b) Same waveform plotted on exptinded scale after correction for access voltage 1 (by subtracting Va), this waveform should be kept inside the water window (—0.6 to +0.9 V for platinum) for safe operation. The pulse length and the charge injection density were 0.2 ms and 400 p,C/cm, respectively. Biphasic cathodic first symmetrical current pulses were used. A saturated calomel electrode (SCE) was used as the reference electrode. From [7], with permission 1990 IEEE... [Pg.17]

Xenia Beebe et al. evaluated the maximum charge injection capacity of activated iridium wire electrodes in bicarbonate buffered saline as 2.1 m C/cm and l.OmC/cm for anodic-first and cathodic-first, 0.2ms charge balanced biphasic current pulses, respectively [1]. Bicarbonate buffered saline has a pH between 7.35 and 7.45 (similar to the human blood plasma) and is comparable to PBS with a pH value of 7.4. The counter electrode was an iridium foil. The reference electrode was a saturated calomel electrode. Cyclic voltammetry at lOOmV/s revealed a water window of -0.6 V +0.8 V, the same as versus Ag AgCl. [Pg.59]

DEC coating was first prepared by Aisenberg and Chabot using ion beam deposition in 1971 [2]. At present, PVD, such as ion beam deposition, sputtering deposition, cathodic vacuum arc deposition, pulsed laser deposition, and CVD, like plasma enhanced chemical vapor deposition are the most popular methods to be selected to fabricate DEC coatings. [Pg.147]

Vacuum arc can also be initiated by pulsed laser, as shown in Fig. 4 [15,16]. The target material is first vaporized into plasma by pulsed laser, and vacuum arc is subsequently initiated and more plasma is generated under the function of the electric field between the anode and the cathode (target). Since the arc is controllable, the surface quality might be evi-... [Pg.148]

The determination of diazepam in plasma with detection limits of 0.03-0.2 fjLg/mh by cathode ray [189] and pulse polarography [174,190] has been described. The first reported pulse assay [174] differs from the other polarographic assays [189,190] in that a more polar solvent is employed to ensure quantitative extraction, followed by TLC separation and determination of diazepam and its major blood metabolite, N-desmethyldiazepam, to ensure specificity. [Pg.804]

Ion Chambers How can we use this primary ionization to produce a detectable signal The first class of devices to be discussed is the pulse-type ion chambers. A sketch of such a device (a parallel-plate ion chamber) is shown in Figure 18.1. Note that one electrode has been connected to the negative terminal of the voltage source, making it the cathode, while the other electrode acts as the anode. [Pg.540]

This section considers that the first potential pulse is set at values corresponding to diffusion-controlled cathodic limiting current conditions for the reactant... [Pg.239]


See other pages where Cathodic first pulses is mentioned: [Pg.1351]    [Pg.117]    [Pg.1351]    [Pg.117]    [Pg.172]    [Pg.474]    [Pg.346]    [Pg.491]    [Pg.530]    [Pg.53]    [Pg.108]    [Pg.108]    [Pg.118]    [Pg.129]    [Pg.219]    [Pg.240]    [Pg.240]    [Pg.35]    [Pg.473]    [Pg.509]    [Pg.53]    [Pg.129]    [Pg.207]    [Pg.119]    [Pg.57]    [Pg.23]    [Pg.38]    [Pg.45]    [Pg.701]    [Pg.119]    [Pg.259]    [Pg.104]    [Pg.636]    [Pg.243]    [Pg.495]    [Pg.510]   
See also in sourсe #XX -- [ Pg.117 ]