Calibration definition

The selection of data in cases where several measurements were reported in the literature was effected according to the chemical purity of the substance (as given by the results of chemical analysis and the absence of a field-dependence for non-ferromagnetic substances), the accuracy of the measurements (established by the precision of the method used, reliability of the calibration, definition of the field and the constancy of the temperature during the time of the measurements) and the presentation of the results (where it is important that the actually measured and not only a derived quantity be reported). Where only a single measurement of the magnetic susceptibility of a certain substance was published, this data is included in the table even if it is suspect to be of insufficient accuracy. [Pg.23]

The transference of a liquid from one vessel to another is best carried out by means of a dropping pipette A (Fig. 30). For measuring out a definite volume of liquid it is obviously an advantage to have a calibrated pipette B (Fig. 30) of i or 5 ml. total capacity. Alternatively, semi-micro burettes reading to 0 02 ml. are particularly convenient for class work. [Pg.59]

A liquid may be transferred from one vessel to another with a dropper pipette (Fig. XII, 1, 2, a or b). If the dropper pipette is calibrated, it may be employed for measuring out a definite volume of liquid. [Pg.1102]

Absolute risk estimates can be difficult to use when there is no apparent human experience against which to calibrate them. By definition, there never exists enough experience about catastrophic rare events (fortunately) with which to calibrate the thinking about their significance. If there were enough data, you would not have elected to do the QRA in the first place. So, now thatyou have a bottom line estimate... [Pg.51]

PROBLEM DEFINITION, QUALITATIVE ERROR PREDICTION AND REPRESENTATION. The recommended problem definition and qualitative error prediction approach for use with SLIM has been described in Section 5.3.1 and 5.3.2. The fact that PIFs are explicitly assessed as part of this approach to qualitative error prediction means that a large proportion of the data requirements for SLIM are already available prior to quantification. SLIM usually quantifies tasks at whatever level calibration data are available, that is, it does not need to perform quantification by combining together task element probabilities from a data base. SLIM can therefore be used for the global quantification of tasks. Task elements quantified by SLIM may also be combined together using event trees similar to those used in THERP. [Pg.235]

Next we turn to the magnitudes of the p constants. Evidently if p = 0, there is no substituent effect on reactivity. Moreover because p = -I-1.000 by definition for the aqueous ionization of benzoic acids, we have a scale calibration of sorts. Wiberg gives examples of p as a measure of the extent of charge development in the transition state. McLennan" has pointed out that p values must first be adjusted for the transmission factor before they can be taken as measures of charge devel-... [Pg.331]

Aufnahme-fahigkeit, /. absorbability, absorptivity, absorbing power capacity. -ge-Bchwindigkeit, /. absorption rate, -kolbeu, m. absorption flask, -pipette,/, a pipet calibrated to take up a definite volume. Cf. Ausflusspipette. -vermogen, n. absorptive power. [Pg.41]

In the extraction procedure the yellow solution is allowed to stand for 10 minutes, and then extracted with 3 mL portions of a 3 1 mixture by volume of pentan-l-ol and ethyl acetate until the last extract is colourless. Make up the combined extracts to a definite volume (10 mL or 25 mL) with the organic solvent, and determine the transmittance (460 nm) at once. Construct the calibration curve by extracting known amounts of bismuth under the same conditions as the sample. [Pg.684]

Definition and Uses of Standards. In the context of this paper, the term "standard" denotes a well-characterized material for which a physical parameter or concentration of chemical constituent has been determined with a known precision and accuracy. These standards can be used to check or determine (a) instrumental parameters such as wavelength accuracy, detection-system spectral responsivity, and stability (b) the instrument response to specific fluorescent species and (c) the accuracy of measurements made by specific Instruments or measurement procedures (assess whether the analytical measurement process is in statistical control and whether it exhibits bias). Once the luminescence instrumentation has been calibrated, it can be used to measure the luminescence characteristics of chemical systems, including corrected excitation and emission spectra, quantum yields, decay times, emission anisotropies, energy transfer, and, with appropriate standards, the concentrations of chemical constituents in complex S2unples. [Pg.99]

Situation Suppose a (monovalent) ionic species is to be measured in an aqueous matrix containing modifiers direct calibration with pure solutions of the ion (say, as its chloride salt) are viewed with suspicion because modifier/ion complexation and modifier/electrode interactions are a definite possibility. The analyst therefore opts for a standard addition technique using an ion-selective electrode. He intends to run a simulation to get a feeling for the numbers and interactions to expect. The following assumptions are made ... [Pg.230]

Another important use of RMs is the maintenance of conventional scales. The octane number of gasoline is an example of such a scale. The scale is defined through chemicals. This definition can be realized through RMs. Another example is the pH scale, which is defined by buffers with pH = 4, pH = 7, and pH = 10. These buffers are defined as mixtures of salts, dissolved in water. These define the pH scale can be used by laboratories for the purpose of calibrating their pH meters. [Pg.10]

A limited number of pure substances are available from NIST, primarily clini-cally-relevant compounds such as cholesterol, urea, uric acid, creatinine, glucose, cortisol, tripalmitin, and bilirubin (NIST SRM website). These compounds are certified for purity (greater than 99 %) and are used as primary calibrants in definitive methods for these clinical analytes (see below). Several additional pure substances are available for specific applications such as microchemistry, i.e. elemental composition (acetanilide, anisic acid, cystine nicotinic acid, o-bromobenzoic acid, p-fluoro-benzoic acid, m-chlorobenzoic acid), polarimetric standards (sucrose and dextrose), acidimetric standard (benzoic acid and boric acid). Only three pure substance NIST RMs are available for environmental contaminants, namely the chlorinated pesticides, lindane, 4,4 -DDT, and 4,4 -DDE. [Pg.85]

A secondary chemical reference substance is a substance whose characteristics are assigned and/or calibrated by comparison with a primary chemical reference substance. The extent of characterization and testing of a secondary chemical reference substance may be less extensive than for a primary chemical reference substance. This definition may apply to some substances termed Working Standards . [Pg.174]

Although accepted by lUPAC and ACS, the k s /m" definition is hard to implement and does not take either variability in method efficiency or matrix effects into consideration. This would be rectifiable if the calibration curves were prepared from control matrix samples fortified at different concentrations (within one order of magnitude of an estimated LOD). [Pg.74]

A better alternative would be to use the propagation of errors definition, which takes into consideration values of both and si when calculating the MDL. This would involve generating at least five calibration curves in order to obtain an accurate measurement of si and Sm ... [Pg.74]

To demonstrate the validity of an analytical method, data regarding working range/ calibration, recovery, repeatability, specificity and LOQ have to be provided for each relevant sample matrix. Most often these data have to be collected from several studies, e.g., from several validation reports of the developer of the method, the independent laboratory validation or the confirmatory method trials. If the intended use of a pesticide is not restricted to one matrix type and if residues are transferred via feedstuffs to animals and finally to foodstuffs of animal origin, up to 30 sets of the quality parameters described above are necessary for each analyte of the residue definition. Table 2 can be used as a checklist to monitor the completeness of required data. [Pg.102]

Peedc-to-peak resolution in SEC can be calculated by the ratio of peak separation at the peak maxiaut to the sum of the baseline peak widths. This general definition of resolution is less useful in SEC, where a measure of the ability of the column to separate solutes of different molecular weight is required. For this purposes, we define a new term, the specific resolution factor, R, which relates peak resolution to sample molecular weight, assuming all measurements are made within the linear region of the molecular weight calibration curve, equation (4.41)... [Pg.739]

In principle, any type of sample can be analysed by SEC provided that it can be solubilised and that there are no enthalpic interactions between sample and packing material. By definition then, this technique cannot be carried out on vulcanisates and even unvulcanised fully compounded rubber samples can present problems due to filler-rubber interactions. The primary use of SEC is to determine the whole MWD of polymers and the various averages (number, viscosity, weight, z-average) based on a calibration curve and to allow qualitative comparisons of different samples. Many commercial polymers have a broad MWD leading to strong peak overlap in the chromatography of complex multicomponent systems. [Pg.261]

It has been emphasized repeatedly that the individual activity coefficients cannot be measured experimentally. However, these values are required for a number of purposes, e.g. for calibration of ion-selective electrodes. Thus, a conventional scale of ionic activities must be defined on the basis of suitably selected standards. In addition, this definition must be consistent with the definition of the conventional activity scale for the oxonium ion, i.e. the definition of the practical pH scale. Similarly, the individual scales for the various ions must be mutually consistent, i.e. they must satisfy the relationship between the experimentally measurable mean activity of the electrolyte and the defined activities of the cation and anion in view of Eq. (1.1.11). Thus, by using galvanic cells without transport, e.g. a sodium-ion-selective glass electrode and a Cl -selective electrode in a NaCl solution, a series of (NaCl) is obtained from which the individual ion activity aNa+ is determined on the basis of the Bates-Guggenheim convention for acr (page 37). Table 6.1 lists three such standard solutions, where pNa = -logflNa+, etc. [Pg.442]


See other pages where Calibration definition is mentioned: [Pg.137]    [Pg.148]    [Pg.137]    [Pg.148]    [Pg.331]    [Pg.82]    [Pg.207]    [Pg.109]    [Pg.31]    [Pg.1141]    [Pg.392]    [Pg.46]    [Pg.53]    [Pg.22]    [Pg.26]    [Pg.118]    [Pg.224]    [Pg.261]    [Pg.86]    [Pg.82]    [Pg.329]    [Pg.174]    [Pg.251]    [Pg.120]    [Pg.106]    [Pg.282]    [Pg.354]    [Pg.68]   
See also in sourсe #XX -- [ Pg.154 ]

See also in sourсe #XX -- [ Pg.14 ]

See also in sourсe #XX -- [ Pg.3 , Pg.5 , Pg.183 ]

See also in sourсe #XX -- [ Pg.62 ]

See also in sourсe #XX -- [ Pg.54 , Pg.55 , Pg.56 ]