Calibrated silica

Fig. 3.19. (a) Calibrated silica particles of diameter 500 nm obtained by the Stober process, (b) Titanium oxide particles adapted to paint applications (mean diameter 200 nm). (c) Titanium oxide fibres of thickness 200 nm and length several microns, usable as a catalyst. The objects in (b) and (c) were obtained from the same titanium salt precursor solution, but under different conditions (photo courtesy of Rhone Poulenc)... [Pg.124]

During evaporation, the resonance frequency of the QBR is monitored (Fig. 12.17b inset). A calibration curve obtained with calibrated silica beads is used to convert the resonance frequency shifts into mass changes so that the temporal evolution of the droplets mass is determined down to around 10 fg (10 aL). [Pg.482]

The furnace and thermostatic mortar. For heating the tube packing, a small electric furnace N has been found to be more satisfactory than a row of gas burners. The type used consists of a silica tube (I s cm. in diameter and 25 cm. long) wound with nichrome wire and contained in an asbestos cylinder, the annular space being lagged the ends of the asbestos cylinder being closed by asbestos semi-circles built round the porcelain furnace tube. The furnace is controlled by a Simmerstat that has been calibrated at 680 against a bimetal pyrometer, and the furnace temperature is checked by this method from time to time. The furnace is equipped with a small steel bar attached to the asbestos and is thus mounted on an ordinary laboratory stand the Simmerstat may then be placed immediately underneath it on the baseplate of this stand, or alternatively the furnace may be built on to the top of the Simmerstat box. [Pg.470]

Photomultipliers are used to measure the intensity of the scattered light. The output is compared to that of a second photocell located in the light trap which measures the intensity of the incident beam. In this way the ratio [J q is measured directly with built-in compensation for any variations in the source. When filters are used for measuring depolarization, their effect on the sensitivity of the photomultiplier and its output must also be considered. Instrument calibration can be accomplished using well-characterized polymer solutions, dispersions of colloidal silica, or opalescent glass as standards. [Pg.692]

The worked out soi ption-photometric method of NIS determination calls preliminary sorption concentration of NIS microamounts from aqueous solutions on silica L5/40. The concentrate obtained is put in a solution with precise concentration of bromthymol-blue (BTB) anionic dye and BaCl, excess. As a result the ionic associate 1 1 is formed and is kept comparatively strongly on a surface. The BTB excess remains in an aqueous phase and it is easy to determinate it photometrically. The linear dependence of optical density of BTB solutions after soi ption on NIS concentration in an interval ITO - 2,5T0 M is observed. The indirect way of the given method is caused by the fact the calibration plot does not come from a zero point of coordinates, and NIS zero concentration corresponds to initial BTB concentration in a solution. [Pg.107]

It is known that Selenium catalyzes reaction of some dye reduction by Sulphide. On this basis spectrophotometric and test-techniques for Selenium determination are developed. Inefficient reproducibility and low sensitivity are their deficiencies. In the present work, solid-phase reagent on silica gel modified first with quaternary ammonium salt and then by Indigocarmine was proposed for Selenium(IV) test-determination. Optimal conditions for the Selenium determination by method of fixed concentration were found. The detection limit of Se(IV) is 10 ftg/L = 2 ng/sample). Calibration curve is linear in the range 50-400 ftg/L of Se(IV). The proposed method is successfully applied to the Selenium determination in multivitamins and bioadditions. [Pg.397]

Recent developments are leading toward other materials like silica gel or polymers. Certain types of semiconductors are also used as resistive probes. The measurement range of resistive sensors varies depending on materials used. It can be as wide as 0-99% RH. The dynamics are fast enough for normal ventilation applications and the stability of good resistive sensors is high. This does not reduce the need for calibration, but the intervals of successive calibrations can be extended. [Pg.1143]

PMMA, on the unmodified porous glass and silica gel, and the universal calibration curves for polystyrenes and poly(methyl methacrylates) did not coincide (10,12,19). [Pg.449]

Procedure. Allow the whole of the sample solution (1 L) to flow through the resin column at a rate not exceeding 5 mL min . Wash the column with 250 mL of de-ionised water and reject the washings. Elute the copper(II) ions with 30 mL of 2M nitric acid, place the eluate in a small conical flask (lOOmL, preferably silica) and evaporate carefully to dryness on a hotplate (use a low temperature setting). Dissolve the residue in 1 mL of 0.1 M nitric acid introduced by pipette and then add 9 mL of acetone. Determine copper in the resulting solution using an atomic absorption spectrophotometer which has been calibrated using the standard copper(II) solutions. [Pg.213]

A calibration curve for the range 0.2-10 mg fluoride ion per 100 mL is constructed as follows. Add the appropriate amount of standard sodium fluoride solution, 25 mL of 2-methoxyethanol, and 10 mg of a buffer [0.1 Af in both sodium acetate and acetic (ethanoic) acid] to a 100 mL graduated flask. Dilute to volume with distilled water and add about 0.05 g of thorium chloranilate. Shake the flask intermittently for 30 minutes (the reaction in the presence of 2-methoxyethanol is about 90 per cent complete after 30 minutes and almost complete after 1 hour) and filter about 10 mL of the solution through a dry Whatman No. 42 filter paper. Measure the absorbance of the filtrate in a 1 cm cell at 540 nm (yellow-green filter) against a blank, prepared in the same manner, using a suitable spectrophotometer. Prepare a calibration curve for the concentration range 0.0-0.2 mg fluoride ion per 100 mL in the same way, but add only 10.0 mL of 2-methoxyethanol measure the absorbance of the filtrate in a 1 cm silica cell at 330 nm. [Pg.701]

Values of are obtained partly by previous calibration using a series of standard light scatterers whose Rayleigh ratios have been precisely determined. Typical standards used in practice are poly(methyl methacrylate) blocks, colloidal silica suspensions, or tungsto-silicic acid, H4SiW 2O40-... [Pg.87]

Burrell and Hurtubise (.32) investigated calibration curves extended well beyond the normal linear range for RTF and RTF of benzoCf)quino-line adsorbed on a silica gel chromatoplate under neutral and acidic conditions. As the benzoCf)quinoline concentration increased, the RTF curves leveled off, whereas the RTF curves passed through a maximum and then decreased. The extended calibration curves along with fluorescence and phosphorescence spectra and phosphorescence lifetimes for benzoCf)quinoline revealed differences in the RTF and RTF phenomena. For example, it was determined that RTF could arise from molecules adsorbed on the surface and in multilayers of molecules, whereas phosphorescence was only generated from molecules adsorbed on the surface of the chromatoplate and not in the multilayers. ... [Pg.165]

Figure 4. SEC calibration curve for silica sol separation (hard sphere particles, single pore size column) (1), Column PSM-1500 (8.9 fim), 30 X 0.78 cm mobile phase O.IU Na.HPO -NaH.PO, pH 8.0... Figure 4. SEC calibration curve for silica sol separation (hard sphere particles, single pore size column) (1), Column PSM-1500 (8.9 fim), 30 X 0.78 cm mobile phase O.IU Na.HPO -NaH.PO, pH 8.0...
Nevertheless, this method was successfully applied by Gulyaeva et al. for the log P and log D determination of 15 P-sympatholytic drugs [56]. Another study by Welerowicz and Buszewski compared the HpophiHcity values of P-blockers obtained with a column made of a monoHthic-silica Cjg with a conventional porous silica particles Cjg as reference material [27]. A modified method was used for evaluating logP with two main differences (i) logfeg was considered rather than retention times, and (ii) benzene and butyl-benzene were used as calibration compounds. [Pg.345]

Ninhydrin Assays. Ninhydrin tests were performed using a modified procedme of Taylor et al. " APS Silica (10-75 mg) of various loadings (0.857, 0.571, and 0.343 mmol NH2/g Silica) was added to phosphate buffer (5 mL, 100 mM, pH 6.5), and 1 mL of a 5% w/v solution of ninhydrin in ethanol was added to the sluny. After stirring for an hour in a boiling water bath, the mixture was allowed to cool slowly to room temperature. The silica was then filtered and washed three times with 70°C distilled water. The filtrate was collected, added to a volumetric flask, diluted to 100 mL, and the absorbance of this solution at 565 mu was measured using a UV-visible spectrophotometer. The reference solution was prepared as above with unmodified amine-free silica. Calibration standards were prepared with aliquots of a 1 mg/mL solution of APS in ethanol. [Pg.341]


See other pages where Calibrated silica is mentioned: [Pg.652]    [Pg.341]    [Pg.58]    [Pg.153]    [Pg.652]    [Pg.341]    [Pg.58]    [Pg.153]    [Pg.577]    [Pg.2964]    [Pg.59]    [Pg.94]    [Pg.231]    [Pg.704]    [Pg.143]    [Pg.145]    [Pg.164]    [Pg.670]    [Pg.163]    [Pg.218]    [Pg.318]    [Pg.661]    [Pg.48]    [Pg.169]    [Pg.203]    [Pg.359]    [Pg.251]    [Pg.374]    [Pg.341]    [Pg.229]    [Pg.224]    [Pg.87]    [Pg.665]    [Pg.467]    [Pg.271]    [Pg.225]    [Pg.579]    [Pg.196]    [Pg.44]    [Pg.378]   