Blank calibration experiments

Gas Evolution. The cold reaction solution was transferred to a calibrated flask at —78°C., connected to a gas buret, and immersed in an ice bath at 0°C. The solution was stirred magnetically at as near a constant rate as possible, and the apparent gas evolution was recorded at convenient time intervals. The gas was identified as oxygen by its absorption in alkaline pyrogallol (no absorption was noted in strong aqueous sodium hydroxide). The real gas evolution was obtained by subtracting from the apparent volume the value obtained in a blank control experiment involving unozonized oxygen. [Pg.6]

As discussed in Section 8.3.8, the confidence limits (CLs) obtained from nonlinear least-squares regression are not very reliable. If time, availability of standards and finances permit, a better feel for the true CLs is obtained by repeating the same experiment (calibration) several times. Similar comments apply to CLs of interpolated values of (Qa /Qsis ) from measured values of (Ra /Rsis) in actual analysis using the nonlinear regression parameters evaluated from the calibration experiments (compare Equation [8.32] for the linear regression case). Of course, as before, the calibrators can in principle be made up either as mixed solutions of pure analytical and internal standards or as extracts of spiked matrix blanks. [Pg.448]

The only recourse is to modify the recovery experiments above in the sense that the sample to be tested itself is used as a kind of blank, to which further analyte is spiked. This results in at least two measurements, namely untreated sample and spiked sample, which can then be used to establish a calibration line from which the amount of analyte in the untreated sample... [Pg.120]

It is slow and tedious for an experiment in which a molecular absorption spectrum is measured. It is slow and tedious because the wavelengths are manually scanned in small increments, and each time the wavelength is changed, the calibration step with the blank needs to be performed due to the variability of light intensity from the light source at the different wavelengths. [Pg.521]

To establish linearity and the linear range, a blank solution, plus at least 6, but preferably 10, independent solutions should be prepared from a traceable reference material and presented to the instrument at least as duplicates and in random order. The range of these solutions then defines the linear range, assuming, of course, statistical analysis of the calibration data supports this contention. How is the range known without doing experiments As stated above, there may be enough prior information to have a... [Pg.245]

Fig. 19 Rapid lifetime determination imaging of the activity of glucose oxidase. Gray-scale image of the activity of glucose oxidase (left) and resulting calibration curve (right). Experiments were performed in triplicate (rows). The wells in the images contained, from 1 to 12, glucose oxidase activities of 0 (blank), 135, 54.1, 27.1, 13.5, 5.4, 2.7, 1.35, 0.54, 0.27, 0.14, and 0.05 mU ml. 1 respectively, 100 jiL of a 0.2 mmol L-1 EuTc solution, and 15 jiL of a 277.2 mmol I. 1 glucose solution. The total volume was made up to 200 xL with MOPS buffer... Fig. 19 Rapid lifetime determination imaging of the activity of glucose oxidase. Gray-scale image of the activity of glucose oxidase (left) and resulting calibration curve (right). Experiments were performed in triplicate (rows). The wells in the images contained, from 1 to 12, glucose oxidase activities of 0 (blank), 135, 54.1, 27.1, 13.5, 5.4, 2.7, 1.35, 0.54, 0.27, 0.14, and 0.05 mU ml. 1 respectively, 100 jiL of a 0.2 mmol L-1 EuTc solution, and 15 jiL of a 277.2 mmol I. 1 glucose solution. The total volume was made up to 200 xL with MOPS buffer...
Example. The Determination of Cd and Pb in Tissues of Animal Origin with ET-AAS LoDs for this method were estimated by using the following experiment. Blank material of meat, liver, and fish were spiked at five concentration levels. The samples were analyzed in duplicate on a Perkin-Elmer SimAA. This experiment was repeated on several occasions. Linearity and homoskedasticity of the calibration curves were not rejected with the Mandels fitting test and visual interpretation of the plot of the residuals. The results described below were obtained. [Pg.158]

To calibrate the EVOM, it is necessary to determine the resistance of the HBSS buffer at the same temperature as used in the experiment. Dip the chopstick electrodes into the buffer, and press the test button to determine the TEER value of the blank buffer. If the obtained value differs from 0, calibrate the EVOM by turning the calibration screw with a screwdriver till the value 0 is reached for the blank buffer (see Note 12). [Pg.158]

Pyrolyser. The catalyst was changed after analysing 15 samples. The recovery efficiency was checked by analysing a known mass of calibrated tritiated thymidine carried on filter paper. This was performed at the beginning and end of the life of the catalyst. After about a year s experience we have recorded a mean efficiency of 90 10%. After each sample run a blank sample of moistened filter paper was analysed to confirm that no cross contamination was occurring between samples. [Pg.13]

The quality control procedures, recovery experiments and blank values were examined. It was decided to reject all data obtained with recovery values exceeding lOO V o by more than the standard deviation. Some of the data were withdrawn, the reasons including bad peak shapes, doubts about calibration, insufficient chromatographic separation, doubts about peak purity incorrect peak assignment. [Pg.418]

The final determination of the CBs was performed by capillary gas chromatography with electron capture detection mass spectrometry was used as complementary technique to confirm the identity of each of the CBs determined. Each participant had validated its method by performing experiments on recovery, extraction efficiency, procedure blanks and detector linearity. The seven individual CB calibrants were supplied to the participants as pure, crystalline CRMs from BCR (CRMs Nos. 291,293, 294,295, 296. 297 and 298). Each laboratory was requested to prepare separate calibration solutions of the appropriate concentration, in iso-octane, to calibrate the detector and lying within its linear range. The use of at least one internal standard was mandatory the participants, however, were left free to select the internal standard(s) best suited to their methods. They had to verify that the selected compounds did not occur in the candidate reference material or did not interfere with compounds present in the material. A series of pure dichlorobenzylalkyl ethers (DCBEs) was made available to the participants but other internal standards were also accepted of which the list is given in the certification report [21] along with additional details on calibration procedures. [Pg.436]

The alkylation of aniline with methanol was carried out in a down-flow reactor (Ld. 6 mm, length 120 mm) and at atmospheric pressure. Catalyst samples (co. 120 mg, <0.149 mm) were pretreated for 1 h at 523 K in a nitrogen flow (3 L h , 99.999%). The aniline-methanol mixtine (1-10 M) was feed from the top through a calibrated motorised syringe (Harward 44) to achieve different WHSV and different aniline conversion levels. Experiments were carried out at temperatures in the range 523-673 K (mostly 523 K). Blanks runs at 673 K showed that the thermal reaction could be neglected. [Pg.124]

A prototype method can be obtained from a pharmaceutical company s QC or discovery group, an academic institution, or some other source, although often the scientist may need to design and develop such a method. Checkerboard experiments [8,10] define the optimal concentration of coating material, detector antibody concentration, and approximate range of the calibration curve. A calibration curve generated in assay buffer serves as a reference to assess the suitability of blank matrix for spiking calibrators and QC samples. [Pg.58]

In comparative testing the standard run is the complement of the blank run it uses a standard feed and a standard catalyst and indicates any unnoticed departures from standard procedure. Despite the reliability of modern instruments, experience shows that time is saved by frequent checking and calibration. [Pg.678]

All gases used were of high purity (99.9997%). The relative sensitivity of the MS for the different gases used was calibrated by the use of known gas mixtures. Blank experiments, without a sample in the reactor, were run in order to check the inertness and the backgroimd levels of the reactor system. [Pg.766]

When preparing the calibration curve experiments in a method characterization or validation experiment, there are some key things to remember. It is important to first examine and plot the detector response to analyte in pure or defined solvent (calibration function) and also at various concentrations in the matrix (i.e., in the presence of interferants, or analytical function). Remember that more standard solutions and more calibration points are required when a non-linear response is observed. Extrapolation above or below the analytical range may be used to approximate behavior at zero if a blank is not included in the calibration standards, but the curve should not be forced through the origin. Typically, a curve prepared by... [Pg.276]

The standard deviation of the null signal in this expression is given in terms of counting statistics if Poisson statistics are not likely to account for most of the random counting error, then it would be prudent to deduce Op from a moderate number of replicates -- le, replace the second term in the numerator of the second factor by 2t Sg Jri, where t is Student s-t and Sp is the estimated standard deviation for the blank (counts). Bounds for systematic error should be based on sound experience or analysis of the measurement process default values that reflect much low-level radionuclide measurement experience are set at 1% [baseline], 5% [blank], and 10% [calibration], respectively. Poisson deviations from normality are adequately accounted for by this expression down to B - 5 background... [Pg.183]


See other pages where Blank calibration experiments is mentioned: [Pg.220]    [Pg.220]    [Pg.220]    [Pg.220]    [Pg.73]    [Pg.278]    [Pg.710]    [Pg.98]    [Pg.204]    [Pg.202]    [Pg.37]    [Pg.32]    [Pg.389]    [Pg.115]    [Pg.217]    [Pg.610]    [Pg.202]    [Pg.235]    [Pg.206]    [Pg.451]    [Pg.385]    [Pg.278]    [Pg.256]    [Pg.11]    [Pg.343]    [Pg.147]    [Pg.318]    [Pg.63]    [Pg.288]    [Pg.18]    [Pg.34]    [Pg.194]    [Pg.192]    [Pg.100]   