Batteries testing

Cold crank performance, battery life expectancy, and freedom from maintenance are generally co-affected by the separators, whereas ampere-hour capacity remains largely unaffected at a given separator thickness. The properties of the different leaf and pocket separators are compared in Table 10. These typical separator properties (lines 1-4) are reflected in the electrical results of battery tests (lines 5-8). The data presented here are based on the 12 V starter battery standard DIN 43 539-02 tests based on other standards lead to similar results. [Pg.269]

The above comparative evaluation of starter battery separators refers to moderate ambient temperatures the standard battery tests arc performed at 40 or 50 °C. What happens, however, on going to significantly higher temperatures, such as 60 or 75 °C This question cannot be answered without considering the alloys used batteries with antimonial alloys show a water consumption that rises steeply with increasing temperature [40], leaving as the only possibilities for such applications either the hybrid construction, i.c., positive electrode with low-antimony alloy, negative electrode lead-calcium, or even both... [Pg.271]

PNGV Battery Test Manual , Revision 1, Idaho National Engineering Laboratory, Department of Energy, DOE/ID-10597 (May, 1998). [Pg.307]

The fall lithium-ion prismatic cells with a rated capacity of 7Ah were assembled and evaluated in the Lithion, Inc. battery test facility. The PNG-based anode materials from Superior Graphite Co. were coated onto copper foil and blanked into anode components for assembly of the so-called... [Pg.332]

The Neurotoxicity Screening Battery test guideline (OPPTS 870.6200) consists of a functional observational battery, motor activity, and neuropathology. The test battery is not intended to provide a complete evaluation of neurotoxicity, and additional functional and morphological evaluation may be necessary to assess completely the neurotoxic potential of a chemical. [Pg.132]

Rat (Sprague- Dawley) once (GO) 2.2 132 (82% decrease in erythrocyte AChE, ataxia, alterations in functional observation battery tests 9 11 hrs post-dosing) Chow and Richter 1994... [Pg.39]

Most battery tests are based simply on cell discharge through fixed resistors (with or without interspersed recovery periods). From the times required to reach predetermined cut-off voltages, estimates of the practical capacity, QP, and of the practical energy, [Pg.61]

Patch testing (and photopatch testing) should document the few cases due to allergic contact dermatitis. Apart from the routine battery, testing should be performed with the fragrance and preservative series, as well as any cosmetic or skin care product that the patient uses. Immediate-type testing should be performed if indicated by the history. If systemic symptoms were present, perform only in the presence of emergency resuscitative facilities. [Pg.496]

ICH/S7A Before first administration to humans Core battery tests and follow-up/supplemenal studies as appropriate During clinical development. Additional studies as required to clarify observed or suspected undesirable effects in animals or humans Before approval. Effects on all organ systems, if not covered elsewhere (e.g. toxicology)... [Pg.770]

GLP/S7A Core battery tests should be conducted according to GLP Follow-up and supplemental studies should be conducted according to GLP as far as possible deviation should be justified and impact discussed Primary and secondary pharmacodynamic studies need not be conducted according toGLP... [Pg.770]

Fig. 14.12 A material spot library and the electric connections to it with an 02 electrode probe and a battery test instrument. The material spot library contains 128 zinc spots spatially separated on a graphite plate. The surface of the graphite is coated with a plastic layer on the non-spot areas to keep ionic insulation between these material spots. The area of each spot is 0.196 cm2. (Reused with permission from Rongzhong Jiang and Deryn Chu.62 Copyright 2005, American Institute of Physics.)... Fig. 14.12 A material spot library and the electric connections to it with an 02 electrode probe and a battery test instrument. The material spot library contains 128 zinc spots spatially separated on a graphite plate. The surface of the graphite is coated with a plastic layer on the non-spot areas to keep ionic insulation between these material spots. The area of each spot is 0.196 cm2. (Reused with permission from Rongzhong Jiang and Deryn Chu.62 Copyright 2005, American Institute of Physics.)...
In a different battery test with a simulated EV load pattern, a SWP-7 cell with an assembly pressure of 60 kPa achieved 450 cycles versus 270 cycles for an AGM cell with 73 kPa. The failure mode was found not to be the expansion of positive plate but, rather, sulfation of the negative plate. This led to the conclusion that the favourable mechanical properties of SWP-type separators suppress degradation of the positive active-material. [Pg.196]

Figure 8-5 shows the different cooling configurations used to study the thermal conductivity along and across the stack. The electrical load and UU curves were measured using a battery test system. The voltage of each cell was monitored separately. Figure 8-6 shows a typical C///curve for the stack. Five fuel cell stacks were used for the experiments described here. [Pg.149]

In contrast to most of the other core battery tests, the rotarod is unidirectional, detecting only the capacity of substances to decrease neuromuscular coordination. On the other hand, when used in conjunction with locomotor achvity tests, it provides a useful quantification of the margin of safety between doses of test substances that alter spontaneous activity and those that disturb motor function. [Pg.76]

An offset in the low frequency sinusoid signal leads to a permanent generation of heat losses to prevent the battery from cooling down to environment temperature. The excitation of the battery is performed with a BaSyTec battery test system. Figure 5a and Figure 5b show current and voltage measurements of a TIS experiment. [Pg.40]

The cathodes for the battery test cells were made from the cathode material, super phosphorus carbon black, and polyvinylidene fluoride (PVDF) binder (Knreha Company) in a weight ratio of 96 2 2. The electrodes were prepared by... [Pg.221]


See other pages where Batteries testing is mentioned: [Pg.579]    [Pg.222]    [Pg.296]    [Pg.261]    [Pg.268]    [Pg.16]    [Pg.60]    [Pg.299]    [Pg.19]    [Pg.141]    [Pg.341]    [Pg.86]    [Pg.232]    [Pg.127]    [Pg.579]    [Pg.159]    [Pg.147]    [Pg.194]    [Pg.201]    [Pg.204]    [Pg.92]    [Pg.324]    [Pg.354]    [Pg.72]    [Pg.41]    [Pg.41]    [Pg.43]    [Pg.213]    [Pg.249]    [Pg.222]    [Pg.326]   


SEARCH



Antibody-dependent test battery

Antigen retrieval test battery standardization

Battery of tests

Battery testing and diagnostic instrumentation

Battery toxicity testing

Computerized performance test batteries

Computerized performance test batteries Assessment Battery

Computerized performance test batteries Battery

Detection system-dependent test battery

Discharge Tests for Battery Materials

Genetic test batteries

Mouse defense test battery

Neurobehavioral core test battery

Neurological test battery

Ranking scheme and battery of tests approach

STANDARDIZATION OF ANTIGEN RETRIEVAL TECHNIQUES BASED ON THE TEST BATTERY APPROACH

Test batteries

Test batteries

Test batteries Assessment Battery

Test batteries with Environmental Stressors Battery

Test battery approach, antigen retrieval

Test battery approaches

Test battery, toxicological

Testing technologies Battery

Watertox toxicity testing battery

© 2024 chempedia.info