Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Application practical applications

The science of catalysis aims at two objectives basic knowledge and practical application. Practical application of any science is intimately related to economics and, accordingly, it is important to see what the driving forces are behind this fabulous application of catalysis in the world s petroleum industry. [Pg.510]

These heuristics are based on observations made in many practical applications. In addition to being restricted to simple columns, the observations are based on no heat integration (i.e., all reboilers and condensers are serviced by utilities). Difficulties can arise when the heuristics are in conflict with each other, as the following example illustrates. [Pg.133]

Although side-stripper arrangements are common in the petroleum industry, designers have been reluctant to use the fully thermally coupled arrangements in practical applications until recently. [Pg.154]

NONDESTRUCTIVE MAGNETIC METHID OF INSPECTION OF THE MECHANICAL PROPERTIES OF CAST STEELS. 1. CONSTRUCTION OF CORRELATION MODELS and II. PRACTICAL APPLICATION OF CORRELATION... [Pg.27]

The performance of the classifier has been verified using a number of practical applications, such as civil engineering [3], inspection of aerospace composite structures, ball bearings and aircraft multi-layer structures. Here we present shortly some results, focusing on detection of disbonds in adhesively joint multi-layer aerospace structures using Fokker Bond Tester resonance instrument, details can be found in [1]. [Pg.107]

The classical computer tomography (CT), including the medical one, has already been demonstrated its efficiency in many practical applications. At the same time, the request of the all-round survey of the object, which is usually unattainable, makes it important to find alternative approaches with less rigid restrictions to the number of projections and accessible views for observation. In the last time, it was understood that one effective way to withstand the extreme lack of data is to introduce a priori knowledge based upon classical inverse theory (including Maximum Entropy Method (MEM)) of the solution of ill-posed problems [1-6]. As shown in [6] for objects with binary structure, the necessary number of projections to get the quality of image restoration compared to that of CT using multistep reconstruction (MSR) method did not exceed seven and eould be reduced even further. [Pg.113]

Practical applications [2] of a GammaMat M model using the new Selenium crawler camera loaded with approx. 1 TBq (30Ci) on a pipeline of diameter 12 and wall thickness of 0.25 showed 6-7 m axial distance to the exposed source as limit of the radiation controlled area (40pSv/h) and 22m perpendicular to the pipeline. Other authors [3] have reported about a comparison for Ir-192 and Selenium source on a 4.5 diameter pipe and 0,125 steel thickness they have found for 0.7 Tbq (18Ci) Selenium a value of 1 Om behind the film (in the unshielded beam) comparing under same conditions to approx. 40m for Iridium. [Pg.428]

The filter according equation (1) allows a practical application of a second derivative, because it has only the noise amplification like a first derivative. This is shown in fig. 3 on a experimental data set. The SNR of the true second derivative is too low for correct edge detection, whereas the CT filter gives reliable results. [Pg.519]

In most practical applications this is approximated by a simpler relationship ... [Pg.521]

But there are many practical applications where no known wall thickness change can be obtained from the radiographic film under consideration because at the exposure it was not... [Pg.563]

Practical applications of the presented algorithm has been done on corrosion monitoring in the pipe system of a power plant. These examples were obtained from a reducing pipe fitting after... [Pg.565]

Side drilled holes are widely used as reference reflectors, especially when angle beam probes are used (e.g. for weld testing). However, the distance law of side drilled holes is different to that of a flat bottomed hole. In the literature [2] a conversion formula is given which allows to convert the diameter of a side drilled hole into the diameter of a flat bottomed hole and vice versa, valid in the far field only, and for diameters greater than 1.5 times the wave length. In practical application this formula can be used down to approximately one nearfield length, without making big mistakes. Fig. 2 shows curves recorded from real flat bottomed holes, and the uncorrected and corrected DGS curves. [Pg.814]

It can easily be shown that an experimentally generated curve coincides with the synthetically generated DGS curve having applicable corrections (transfer loss and sound attenuation) with acceptable tolerances. However, our intention is not to replace the reference block method by the DGS method. In practical application you may encounter many cases, where only the reference block method can be applied, e.g. ... [Pg.814]

The use of the surface ultrasonic waves seems to be convenient for these purposes. However, this method has not found wide practical application. Peculiarities of excitation, propagation and registration of surface waves created before these time great difficulties for their application in automatic systems of duality testing. It is connected with the fact that the surface waves are weakened by soil on the surface itself In addition, the methods of testing by the surface waves do not yield to automation due to the difficulties of creation of the acoustic contact. In particular, a flow of contact liquid out of the zone of an acoustic line, presence of immersion liquid, availability of chink interval leads to the adsorption and reflection of waves on tlie front meniscus of a contact layer. The liquid for the acoustic contact must be located only in the places of contact, otherwise the influence on the amplitude will be uncontrolled. This phenomenon distorts the results of testing procedure. [Pg.876]

After having proved the principles a dynamic test facility has been constructed. In this facility it is possible to inject 3 tracers in a flownng liquid consisting of air, oil and water. By changing the relative amounts of the different components it is possible to explore the phase diagram and asses the limits for the measurement principle. Experiments have confirmed the accuracy in parameter estimation to be below 10%, which is considered quite satisfactorily for practical applications. The method will be tested on site at an offshore installation this summer. [Pg.1057]

The influence of electrical charges on surfaces is very important to their physical chemistry. The Coulombic interaction between charged colloids is responsible for a myriad of behaviors from the formation of opals to the stability of biological cells. Although this is a broad subject involving both practical application and fundamental physics and chemistry, we must limit our discussion to those areas having direct implications for surface science. [Pg.169]

An interesting and very practical application of Amontons law occurs in the calculation of the minimum speed of a vehicle from the length of its skid marks. [Pg.437]

While hopes are high, heterogeneous photochemical systems seem not yet to have found major practical application. The photovoltaic cell or solar cell is the only system with important (although specialized) commercial use (see Ref. 343). [Pg.739]

F. Zaera and G. A. Somoijai, in Hydrogen Effects in Catalysis Fundamentals and Practical Applications, Z. Paal and P. G. Menon, eds., Marcel Dekker, New York, 1988. [Pg.747]

Weii J A, Boiton J R and Wertz J E 1994 Electron Paramagnetic Resonance Elementary Theory and Practical Applications (New York Wiiey)... [Pg.1622]

Other solubilization and partitioning phenomena are important, both within the context of microemulsions and in the absence of added immiscible solvent. In regular micellar solutions, micelles promote the solubility of many compounds otherwise insoluble in water. The amount of chemical component solubilized in a micellar solution will, typically, be much smaller than can be accommodated in microemulsion fonnation, such as when only a few molecules per micelle are solubilized. Such limited solubilization is nevertheless quite useful. The incoriDoration of minor quantities of pyrene and related optical probes into micelles are a key to the use of fluorescence depolarization in quantifying micellar aggregation numbers and micellar microviscosities [48]. Micellar solubilization makes it possible to measure acid-base or electrochemical properties of compounds otherwise insoluble in aqueous solution. Micellar solubilization facilitates micellar catalysis (see section C2.3.10) and emulsion polymerization (see section C2.3.12). On the other hand, there are untoward effects of micellar solubilization in practical applications of surfactants. Wlren one has a multiphase... [Pg.2592]

For practical applicability, several aspects have to be considered such as tire anode material (sacrificial (e.g. zinc) or inert (e.g. Pt/Ti or graphite)), tlie conductivity of tlie medium and tlie current distribution. Catliodic protection is typically used for buried constmctions (e.g. pipelines), off-shore stmctures or ship hulls. [Pg.2730]

Germanium is very similar to Si, but its band gap is too small for many practical applications. Large crystals of ultra-high-purity Ge have been grown for use as gamma-ray detectors. In such crystals, the net concentration of... [Pg.2878]

All teclmologically important properties of semiconductors are detennined by defect-associated energy levels in the gap. The conductivity of pure semiconductors varies as g expf-A CgT), where is the gap. In most semiconductors with practical applications, the size of the gap, E 1-2 eV, makes the thennal excitation of electrons across the gap a relatively unimportant process. The introduction of shallow states into the gap through doping, with either donors or acceptors, allows for large changes in conductivity (figure C2.16.1). The donor and acceptor levels are typically a few meV below the CB and a few tens of meV above the VB, respectively. The depth of these levels usually scales with the size of the gap (see below). [Pg.2882]

In practical applications, gas-surface etching reactions are carried out in plasma reactors over the approximate pressure range 10 -1 Torr, and deposition reactions are carried out by molecular beam epitaxy (MBE) in ultrahigh vacuum (UHV below 10 Torr) or by chemical vapour deposition (CVD) in the approximate range 10 -10 Torr. These applied processes can be quite complex, and key individual reaction rate constants are needed as input for modelling and simulation studies—and ultimately for optimization—of the overall processes. [Pg.2926]

The center of the wavepacket thus evolves along the trajectory defined by classical mechanics. This is in fact a general result for wavepackets in a hannonic potential, and follows from the Ehrenfest theorem [147] [see Eqs. (154,155) in Appendix C]. The equations of motion are straightforward to integrate, with the exception of the width matrix, Eq. (44). This equation is numerically unstable, and has been found to cause problems in practical applications using Morse potentials [148]. As a result, Heller inboduced the P-Z method as an alternative propagation method [24]. In this, the matrix A, is rewritten as a product of matrices... [Pg.273]


See other pages where Application practical applications is mentioned: [Pg.231]    [Pg.407]    [Pg.231]    [Pg.407]    [Pg.105]    [Pg.106]    [Pg.127]    [Pg.128]    [Pg.191]    [Pg.218]    [Pg.252]    [Pg.565]    [Pg.709]    [Pg.845]    [Pg.944]    [Pg.9]    [Pg.362]    [Pg.436]    [Pg.467]    [Pg.970]    [Pg.1215]    [Pg.1362]    [Pg.2602]    [Pg.2731]    [Pg.2776]    [Pg.2877]    [Pg.3010]    [Pg.3032]   
See also in sourсe #XX -- [ Pg.42 , Pg.43 , Pg.44 , Pg.45 , Pg.46 , Pg.47 , Pg.48 , Pg.49 , Pg.50 ]




SEARCH



Practical applications

© 2024 chempedia.info