Analysis strategies standard methods

Minimal sample preparation (dilution in HPLC mobile phase) is necessary. A standard reversed-phase HPLC method is used for all the samples associated with a drug candidate to reduce time-consuming method development/method refinement procedures. Standard reversed-phase methods typically involve a 20-30 min cycle time and provide information on a wide range of compounds. The incorporation of a standard method strategy allows the use of autosampling procedures and standard system software for data analysis. [Pg.140]

Systematic review The application of strategies that limit bias in the assembly, critical appraisal and synthesis of all relevant studies on a specific topic. Systematic reviews focus on peer-reviewed publications about a specific health problem and use rigorous, standardized methods to select and assess articles. A systematic review differs from a meta-analysis in not including a quantitative summary of the results (Porta 2008). [Pg.741]

Several strategies have been described for the preconcentration of sample components present at low concentrations. These techniques include zone sharpening,28-29 on-line packed columns,30 and transient capillary isotachophoresis (cITP).31-32 Other standard laboratory techniques are often used, including solid-phase extraction, protein precipitation, ultrafiltration, etc. Two important points to keep in mind when selecting a concentration protocol are the sample requirements of the method and the potential selectivity on relative concentrations of sample components. The latter point applies to purity and concentration analysis. [Pg.179]

In the response surface strategy that was discussed in Section 2.3 standard response surface techniques are used to generate two response surface models, one for the mean response and one for the standard deviation of the response (or some function of the standard deviation). The standard deviation measures the stability of the response to the environmental variation. Standard analysis can reveal which factors affect the mean only, which only affect the variability, and which affect both the mean and the variability. The researcher can then apply optimization methods or construct contour plots of the mean and standard deviation response surfaces to determine settings of the design variables that will give a mean response that is close to the target with minimum variation. [Pg.74]

The validation requirements are discussed as they apply to both the sample preparation and sample analysis aspects of a dissolution method. The focus of the discussion in this chapter is on the validation considerations that are unique to a dissolution method. Validation is the assessment of the performance of a defined test method. The result of any successful validation exercise is a comprehensive set of data that will support the suitability of the test method for its intended use. To this end, execution of a validation exercise without a clearly defined plan can lead to many difficulties, including an incomplete or flawed set of validation data. Planning for the validation exercise must include the following determination of what performance characteristics to assess (i.e., strategy), how to assess each characteristic (i.e., experimental), and what minimum standard of performance is expected (i.e., criteria). The preparation of a validation protocol is highly recommended to clearly define the experiments and associated criteria. Validation of a test method must include experiments to assess both the sample preparation (i.e., sample dissolution) and the sample analysis. ICH Q2A [1] provides guidance for the validation characteristics of the dissolution test and is summarized in Table 4.1. [Pg.53]

Internal standard (IS) calibration requires ratioing of an analytical signal to an IS which has very similar characteristics to that of the analyte of interest (an element which is similar to the analyte either in mass, ionisation potential or chemical behaviour). Quantitative analysis applying internal standardisation is the most popular calibration strategy in ICP-MS, as improvements in precision are obtained when the technique is appropriately used. Of course, the validity of this calibration method requires that one ensures a good selection of the correct internal standard. For this purpose it is possible to resort to chemometric methods [16]. [Pg.26]


See other pages where Analysis strategies standard methods is mentioned: [Pg.812]    [Pg.224]    [Pg.57]    [Pg.407]    [Pg.119]    [Pg.95]    [Pg.32]    [Pg.17]    [Pg.42]    [Pg.43]    [Pg.46]    [Pg.62]    [Pg.124]    [Pg.133]    [Pg.169]    [Pg.307]    [Pg.224]    [Pg.3428]    [Pg.160]    [Pg.51]    [Pg.60]    [Pg.5]    [Pg.145]    [Pg.130]    [Pg.811]    [Pg.23]    [Pg.323]    [Pg.194]    [Pg.33]    [Pg.335]    [Pg.77]    [Pg.92]    [Pg.195]    [Pg.350]    [Pg.199]    [Pg.167]    [Pg.417]    [Pg.326]    [Pg.136]    [Pg.586]    [Pg.402]    [Pg.207]    [Pg.349]   