Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Flow volumetric

For calculation of the volumetric flow rate only the cross section area of the pipe is to be known. In order to give flow under standard conditions the temperature and pressure must be measured, and for conversion to mass flow the composition or density of the gas must be determined. These process parameters are often monitored by calibrated instrumentation. [Pg.1054]

E. Interrelationships in Electrokinetic Phenomena In electroosmosis, the volumetric flow and current are related through... [Pg.188]

Accuracies of the flow meters discussed herein are specified as either a percentage of the full-scale flow or as a percentage of the actual flow rate. It may be convenient in some appHcations to compare the potential inaccuracies in actual volumetric flow rates. For example, in reading two Hters per minute (LPM) on a flow meter rated for five LPM, the maximum error for a 1% of full-scale accuracy specification would be 0.01 x 5 = 0.05 LPM. If another flow meter of similar range, but having 1% of actual flow rate specification, were used, the maximum error would be 0.01 x 2 = 0.02 LPM. To minimize errors, meters having full-scale accuracy specifications are normally not used at the lower end of their range. Whenever possible, performance parameters should be assessed for the expected installation conditions, not the reference conditions that are the basis of nominal product performance specifications. [Pg.56]

Meters can be further divided into three subgroups depending on whether fluid velocity, the volumetric flow rate, or the mass flow rate is measured. The emphasis herein is on common flow meters. Devices of a highly specialized nature, such as biomedical flow meters, are beyond the scope of this article. [Pg.58]

Measurement by Electromagnetic Effects. The magnetic flow meter is a device that measures the potential developed when an electrically conductive flow moves through an imposed magnetic field. The voltage developed is proportional to the volumetric flow rate of the fluid and the magnetic field strength. The process fluid sees only an empty pipe so that the device has a very low pressure drop. The device is useful for the measurement of slurries and other fluid systems where an accumulation of another phase could interfere with flow measurement by other devices. The meter must be installed in a section of pipe that is much less conductive than the fluid. This limits its appHcabiHty in many industrial situations. [Pg.110]

The framework for the solution of porous media flow problems was estabUshed by the experiments of Henri Darcy in the 1800s. The relationship between fluid volumetric flow rate, hydraulic gradient, and cross-sectional area, yi, of flow is given by the Darcy formula ... [Pg.402]

Fig. 17. Heat-transfer coefficient comparisons for the same volumetric flow rates for (A) water, 6.29 kW, and a phase-change-material slurry (O), 10% mixture, 12.30 kW and ( ), 10% mixture, 6.21 kW. The Reynolds number was 13,225 to 17,493 for the case of water. Fig. 17. Heat-transfer coefficient comparisons for the same volumetric flow rates for (A) water, 6.29 kW, and a phase-change-material slurry (O), 10% mixture, 12.30 kW and ( ), 10% mixture, 6.21 kW. The Reynolds number was 13,225 to 17,493 for the case of water.
Computer Models, The actual residence time for waste destmction can be quite different from the superficial value calculated by dividing the chamber volume by the volumetric flow rate. The large activation energies for chemical reaction, and the sensitivity of reaction rates to oxidant concentration, mean that the presence of cold spots or oxidant deficient zones render such subvolumes ineffective. Poor flow patterns, ie, dead zones and bypassing, can also contribute to loss of effective volume. The tools of computational fluid dynamics (qv) are useful in assessing the extent to which the actual profiles of velocity, temperature, and oxidant concentration deviate from the ideal (40). [Pg.57]

Flow. The principal types of flow rate sensors are differential pressure, electromagnetic, vortex, and turbine. Of these, the first is the most popular. Orifice plates and Venturi-type flow tubes are the most popular differential pressure flow rate sensors. In these, the pressure differential measured across the sensor is proportional to the square of the volumetric flow rate. [Pg.65]

Capillary viscometers are useful for measuring precise viscosities of a large number of fluids, ranging from dilute polymer solutions to polymer melts. Shear rates vary widely and depend on the instmments and the Hquid being studied. The shear rate at the capillary wall for a Newtonian fluid may be calculated from equation 18, where Q is the volumetric flow rate and r the radius of the capillary the shear stress at the wall is = r Ap/2L. [Pg.180]

Piston Cylinder (Extrusion). Pressure-driven piston cylinder capillary viscometers, ie, extmsion rheometers (Fig. 25), are used primarily to measure the melt viscosity of polymers and other viscous materials (21,47,49,50). A reservoir is connected to a capillary tube, and molten polymer or another material is extmded through the capillary by means of a piston to which a constant force is appHed. Viscosity can be determined from the volumetric flow rate and the pressure drop along the capillary. The basic method and test conditions for a number of thermoplastics are described in ASTM D1238. Melt viscoelasticity can influence the results (160). [Pg.182]

Before a source analysis program is undertaken, it is important to decide which information is really required. Sampling sites must be selected with care. Choice of the site can significantly affect accuracy and cost. Care must also be taken in the selection of sampling points at the site. Measurement usually involves the deterrnination of temperature, concentration, and characterization of the gas contaminants. It also requires the mass rates of emission of each contaminant, therefore concentration and volumetric flow data are required. [Pg.299]

The diameter of the air core varies with the feed volumetric flow rate. If the rate is too low, there is no air core and all of the pulp leaves the cyclone as underflow if the rate is too high, the air core expands, closing off the apex and forcing all of the pulp to leave the cyclone as overflow. Consequently there is a minimum and maximum volumetric feed rate. Because the pressure drop is proportional to the square of the volumetric feed rate, the minimum and maximum rates can be monitored by the pressure drop. The ratio of the maximum pressure drop to the minimum pressure drop should be less than 4, meaning the maximum to minimum volumetric feed rate should be less than 2. [Pg.437]

The Displacement Distance theory suggests that since the stmcture of the flame is only quantitatively correct, the flame height can be obtained through the use of the displacement length or "displacement distance" (35,36) (eq. 12), where h = flame height, m V = volumetric flow rate, m /s and D = diffusion coefficient. [Pg.519]

Consider the case of the simple Bunsen burner. As the tube diameter decreases, at a critical flow velocity and at a Reynolds number of about 2000, flame height no longer depends on the jet diameter and the relationship between flame height and volumetric flow ceases to exist (2). Some of the characteristics of diffusion flames are illustrated in Eigure 5. [Pg.519]

In any gas burner some mechanism or device (flame holder or pilot) must be provided to stabilize the flame against the flow of the unbumed mixture. This device should fix the position of the flame at the burner port. Although gas burners vary greatly in form and complexity, the distribution mechanisms in most cases are fundamentally the same. By keeping the linear velocity of a small fraction of the mixture flow equal to or less than the burning velocity, a steady flame is formed. From this pilot flame, the main flame spreads to consume the main gas flow at a much higher velocity. The area of the steady flame is related to the volumetric flow rate of the mixture by equation 18 (81,82)... [Pg.523]

The volumetric flow rate of the mixture is, in turn, proportional to the rate of heat input (eq. 19) ... [Pg.523]

The function of clear-Hquor advance can be illustrated by considering a simple operation, shown in Figure 13, in which Qcv < 0 volumetric flow rates of clear-Hquor fed to the crystallizer, in the clear-Hquor advance, and in the output slurry. In such systems the population density function is given by the expression... [Pg.351]

Both catalyst space velocity and bed geometry play a role. The gas hourly space velocity (GHSV) is used to relate the volumetric flow rate to the catalyst volume. GHSV has units of inverse hour and is defined as the volume flow rate per catalyst volume. [Pg.506]

For theJth. component, my = m iDy is the component mass flow rate in stream i is the mass fraction of component j in stream i and q is the net reaction rate (mass generation minus consumption) per unit volume V that contains mass M. If it is inconvenient to measure mass flow rates, the product of density and volumetric flow rate is used instead. [Pg.592]


See other pages where Flow volumetric is mentioned: [Pg.413]    [Pg.413]    [Pg.391]    [Pg.55]    [Pg.58]    [Pg.58]    [Pg.64]    [Pg.84]    [Pg.84]    [Pg.258]    [Pg.499]    [Pg.508]    [Pg.509]    [Pg.311]    [Pg.79]    [Pg.17]    [Pg.463]    [Pg.283]    [Pg.523]    [Pg.523]    [Pg.153]    [Pg.335]    [Pg.335]    [Pg.90]    [Pg.177]    [Pg.177]    [Pg.177]    [Pg.229]    [Pg.474]    [Pg.549]    [Pg.590]   
See also in sourсe #XX -- [ Pg.10 ]

See also in sourсe #XX -- [ Pg.99 ]

See also in sourсe #XX -- [ Pg.107 ]

See also in sourсe #XX -- [ Pg.612 , Pg.616 ]

See also in sourсe #XX -- [ Pg.114 ]




SEARCH



Dimensionless volumetric flow rate

Fetal volumetric flow rate

Fixed volumetric flow rate, pipe

Flow measurement volumetric

Further methods of measuring volumetric flow

Maternal volumetric flow rate

Pitot tube volumetric flow rate, calculation

Relative volumetric flow rate

Rotameters volumetric flow-rates

Standard volumetric flow rate

Variable volumetric flow rate

Volumetric flow calculation

Volumetric flow differential reactors

Volumetric flow rate 618 Subject

Volumetric flow rate and average velocity in a pipe

Volumetric flow rate measurement

Volumetric flow rate washout

Volumetric flow rate wastewater

Volumetric flow rate water

Volumetric flow rate well-mixed

Volumetric flow rate work term

Volumetric flow rate, axisymmetric

Volumetric flow rate, capillary

Volumetric flow tubular reactors

Volumetric flow variable

Volumetric flow-rate

Volumetric gas flow

Volumetric solid flow rate

© 2024 chempedia.info