Volumetric flow rate Subject

A closer look at the trends of the straight lines in Section 4.3.1 reveals a deviation that is common to all the curves. To illustrate this, let us take two curves that display this behaviour particularly clearly and that are suitable from the point of view of shear rate. When considering the shear rates plotted here, it must be remembered that at. Vy = 1000 s " the flow is in the critical range for the transition to turbulent flow, and also that low shear rates result in very low volumetric flow rates during measurement and are therefore subject to sizeable variations. For this reason Sy = 500 s was chosen as a suitable shear rate. The specimens chosen were Pebax with Loxiol and PS N 2000, in each case with Printex XE-2. The specimens with Printex XE-2 are especially suitable because even small differences in concentration lead to measurable changes in viscosity and the readings therefore yield a particularly clear picture. [Pg.545]

The total efficiency can be determined from three different combinations of the material streams involved (equation 3.5 combined with the mass balance in equation 3.1) the mass flow rates of the solids are usually determined by measuring the total volumetric flow rates and the corresponding solids concentrations the mass flow rate is, of course, the product of the two. The combination giving the smallest standard deviation of Ei (if all the variables are subject to random errors only) is that of the overflow and underflow streams. (The same conclusion applies to the testing of G x).)... [Pg.77]

The water heater as shown in Figure 5.63 is a well-mixed, constant-volume (Vi) tank through which fluid flows at a constant mass flow rate w (or p/E whereas F is the volumetric flow rate and p/ is the liquid density) the specific heat capacity of the fluid is C /. Because the incoming fluid temperature Tf is subject to fluctuations, an electric coil to which a simple proportional con-... [Pg.442]

How does this control scheme respond to disturbances The major control objective is to produce a side stream of essentially pure benzene, approximately 99 per cent. To test this control scheme, the column was subjected to two different types of disturbance. The first disturbance was that of an increase in the total volumetric flow rate of the feed introduced to the column. A strip chart of the feed flow rate, the three product flow rates and the side stream benzene purity is shown in Figure 8.12. A step change in the feed flow rate is introduced, increasing the flow rate from 11.5 m h to 12.075 m h This corresponds to an increase of 5 per cent. [Pg.200]

This test method for measuring the high temperature stability of gas turbine fuels uses the Jet Fuel Thermal Oxidation Tester (JFTOT) that subjects the test fuel to conditions that can be related to those occurring in gas turbine engine fuel systems. The fuel is pumped at a fixed volumetric flow rate through a beater after which it enters a precision stainless steel filter where fuel d radation products may become trapped. [Pg.527]

In practice, the complete viscosity functions are often not specified for polymer melts. Instead, the melt flow rate (MFR) and/or the melt volumetric rate (MVR) is used. These parameters specify how much polymer mass and/or volume will flow out of a normalized flow channel within a specific period (e. g [cm3/10 min]) when subjected to stress (see DIN EN ISO 113, ASTM D1238). Low-viscosity, easily flowing polymers have high MFR or MVI values, while high viscosity/slow flowing polymers have low MFR or MVI values. These values are listed e.g. in plastics databases such as CAMPUS [3],... [Pg.40]

Topical dorzolamide does not appear to cause a change in retinal circulatory variables, including venous diameter and volumetric blood flow rate, after a single dose in normal subjects. The drug also does not have any apparent effect on retrobulbar hemodynamics as determined by color Doppler imaging. In some studies, however, improvements in retinal, choroidal, and retrobulbar blood flow as determined by various assessment methods and hemodynamic markers demonstrate that dorzolamide alone or in combination therapy may improve ocular blood flow in patients with glaucoma and ocular... [Pg.164]


See other pages where Volumetric flow rate Subject is mentioned: [Pg.79]    [Pg.151]    [Pg.114]    [Pg.31]    [Pg.79]    [Pg.226]    [Pg.153]    [Pg.60]    [Pg.242]    [Pg.114]    [Pg.277]    [Pg.872]    [Pg.189]    [Pg.31]    [Pg.3014]    [Pg.115]    [Pg.774]    [Pg.263]    [Pg.306]    [Pg.434]    [Pg.1396]    [Pg.219]    [Pg.341]    [Pg.356]    [Pg.3]   