Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Virtual analysis

Hayward et al. 1994] Hayward, S., Kitao, A., Go, N. Harmonic and anharmonic aspects in the dynamics of BPTI A normal mode analysis and principal component analysis. Prot. Sci. 3 (1994) 936-943 [Head-Gordon and Brooks 1991] Head-Gordon, T., Brooks, C.L. Virtual rigid body dynamics. Biopol. 31 (1991) 77-100... [Pg.76]

In general, the first step in virtual screening is the filtering by the application of Lipinski s Rule of Five [20]. Lipinski s work was based on the results of profiling the calculated physical property data in a set of 2245 compounds chosen from the World Drug Index. Polymers, peptides, quaternary ammonium, and phosphates were removed from this data set. Statistical analysis of this data set showed that approximately 90% of the remaining compounds had ... [Pg.607]

R and M M Hann 2000. The In Silico World of Virtual Libraries. Drug Discovery Today 5 326-336. R and I D Kuntz 1990. Conformational Analysis of Flexible Ligands in Macromolecular eptor Sites. Journal of Computational Chemistry 13 730-748. [Pg.740]

It is regretted that the size of the volume has rendered the insertion of literature references impossible the Selected Bibliography (A,5) may partly compensate for this omission. Section numbers are now included in the headings of the pages—a feature introduced in response to requests by many readers. The volume comprises virtually at least three books under one cover, viz., experimental technique, preparations, and qualitative organic analysis. It should therefore continue to be of value as a one volume reference work in the laboratory. Students at all levels will find their requirements for laboratory work (excluding quantitative organic analysis) adequately provided for and, furthermore, the writer hopes that the book will be used as a source of information to supplement their theoretical studies. [Pg.1192]

Selection and Standardization of Titrants EDTA is a versatile titrant that can be used for the analysis of virtually all metal ions. Although EDTA is the most commonly employed titrant for complexation titrations involving metal ions, it cannot be used for the direct analysis of anions or neutral ligands. In the latter case, standard solutions of Ag+ or Hg + are used as the titrant. [Pg.327]

B. W. Loo, J. M. JaMevic, and F. S. Goulding, "Dichotomous Virtual Impactors for Large Scale Monitoring of Airborne Particulate Matter," in B. Y. H. Liu, ed., Eine Particles, Aerosol Generation, Measurement, Sampling and Analysis, Academic Press, Inc., New York, 1976, pp. 311—350. [Pg.414]

The chemical analysis of waste fuels also demonstrates that the wood-based fuels contain virtually no sulfur and Htde nitrogen. Unless the hog fuel contains bark from logs previously stored ia salt-water, the chlorine content is very modest to nonmeasurable. [Pg.54]

For capillary columns fused siHca is the material of choice for the column container. It has virtually no impurities (<1 ppm metal oxides) and tends to be quite inert. In addition, fused siHca is relatively easily processed and manufacture of columns from this material is reproducible. In trace analysis, inertness of tubing is an important consideration to prevent all of the tiny amounts of sample from becoming lost through interaction with the wall during an analysis. [Pg.107]

The process monitors and controllers typically also have the capabiUty for data logging, analysis, and display. This capabiUty has made on-line control of pilot plants, as well as commercial-scale processes, desirable. Pilot-plant appHcations for on-line control have been described (106), and the use of such systems for both monitoring and process diagnosis has been discussed (107). A number of commercially available process control programs that mn on microprocessors have been reviewed (108). Virtually all of them incorporate graphic display as an integral part of the interactive capabiUty of the program. [Pg.65]

The pyrimidine ring is virtually flat. Its corrected bond lengths, as determined by a least-squares analysis of the crystal structure data for a unit cell of four molecules, are shown in formula (2) (60AX80), and the bond angles derived from these data show good agreement with those (3) derived by other means (63JCS5893) for comparison, each bond... [Pg.58]

If we take the nominal fracture toughness of IG-11 graphite to be 1 MPayin and the maximum stress in the process zone to be = 60.2 MPa according to the above analysis, we find that rj, = 88 pm. This value is virtually identical to r<, , = 90pm, the process zone dimension determined using Eq. 3. To summarize, the above analysis strongly supports a hypothesis that the maximum critical stress... [Pg.513]

The main product, benzene, is represented by solute (B), and the high boiling aromatics are represented by solute (C) (toluene and xylenes). The analysis of the products they obtained are shown in Figure 12. The material stripped form the top section (section (1)) is seen to contain the alkanes, alkenes and naphthenes and very little benzene. The product stripped from the center section appears to be virtually pure benzene. The product from section (3) contained toluene, the xylenes and thiophen which elutes close to benzene. The thiophen, however, was only eliminated at the expense of some loss of benzene to the lower stripping section. Although the system works well it proved experimentally difficult to set up and maintain under constant operating conditions. The problems arose largely from the need to adjust the pressures that must prevent cross-flow. The system as described would be virtually impossible to operate with a liquid mobile phase. [Pg.438]

Chiesa and Consonni [1 gave another detailed analysis for this plant in comparison with Cycle A1. They found that the efficiency dropped by 5% from that of the basic CCGT plant this is. somewhat surprising as the ab.sorption plant is smaller than that for Cycle A1 and it might have been expected that the penalty on efficiency of intrcxlucing the absorption plant would have been much less than that of Cycle Al. With this calculated efficiency and a detailed estimate of capital cost, the price of electricity was virtually the same as that of Cycle Al, i.e. 40% greater than that of the basic CCGT plant. [Pg.146]

For a theoretical analysis of SFA experiments it is prudent to start from a somewhat oversimplified model in which a fluid is confined by two parallel substrates in the z direction (see Fig. 1). To eliminate edge effects, the substrates are assumed to extend to infinity in the x and y directions. The system in the thermodynamic sense is taken to be a lamella of the fluid bounded by the substrate surfaces and by segments of the (imaginary) planes x = 0, jc = y = 0, and y = Sy. Since the lamella is only a virtual construct it is convenient to associate with it the computational cell in later practical... [Pg.5]

One of the most noticeable ergonomic deficiencies in both control rooms was the number of panels that had to be scanned and monitored during the scenarios, and the number of rapid actions required at opposite ends of the control room. The need for virtually simultaneous actions and movements would have been discovered and resolved in the design stage had a task analysis and human error analysis been carried out on an emergency operation. [Pg.339]

Gels made in this way have virtually no usable porosity and are called Jordi solid bead packings. They can be used in the production of low surface area reverse phase packings for fast protein analysis and in the manufacture of hydrodynamic volume columns as well as solid supports for solid-phase syntheses reactions. An example of a hydrodynamic volume column separation is shown in Fig. 13.2 and its calibration plot is shown in Fig. 13.3. The major advantage of this type of column is its ability to resolve very high molecular weight polymer samples successfully. [Pg.369]

Include the keywords IOP(9/40=3) and Pop=Full in the route section of your jobs. The latter requests that all molecular orbitals (occupied and virtual) be included in the population analysis, while the former specifies that all wavefunctioii coefficients greater than 0.001 be included in the excited state output (by default, only those greater than 0.1 are listed). [Pg.225]

Before computer-based systems were developed, a major limitation of vibration monitoring programs was the labor required to manage, store, retrieve, and analyze the massive amount of data generated. However, the computer-based systems in use today virtually eliminate this labor requirement. These systems automatically manage data and provide almost instant data retrieval for analysis. [Pg.699]

In making the analysis it is assumed that the anode groundbed is remote from the pipeline. That is, the length of the pipeline in question stands in what is virtually a uniform anode field, as shown in Fig. 10.11. Since the... [Pg.130]

In these equations, Dmax is the larger of the summed values of STERIMOL parameters, Bj, for the opposite pair 68). It expresses the maximum total width of substituents. The coefficients of the ct° terms in Eqs. 37 to 39 were virtually equal to that in Eq. 40. This means that the a° terms essentially represent the hydrolytic reactivity of an ester itself and are virtually independent of cyclodextrin catalysis. The catalytic effect of cyclodextrin is only involved in the Dmax term. Interestingly, the coefficient of Draax was negative in Eq. 37 and positive in Eq. 38. This fact indicates that bulky substituents at the meta position are favorable, while those at the para position unfavorable, for the rate acceleration in the (S-cyclodextrin catalysis. Similar results have been obtained for a-cyclodextrin catalysis, but not for (S-cyclodextrin catalysis, by Silipo and Hansch described above. Equation 39 suggests the existence of an optimum diameter for the proper fit of m-substituents in the cavity of a-cyclodextrin. The optimum Dmax value was estimated from Eq. 39 as 4.4 A, which is approximately equivalent to the diameter of the a-cyclodextrin cavity. The situation is shown in Fig. 8. A similar parabolic relationship would be obtained for (5-cyclodextrin catalysis, too, if the correlation analysis involved phenyl acetates with such bulky substituents that they cannot be included within the (5-cyclodextrin cavity. [Pg.85]


See other pages where Virtual analysis is mentioned: [Pg.426]    [Pg.145]    [Pg.426]    [Pg.145]    [Pg.366]    [Pg.313]    [Pg.616]    [Pg.474]    [Pg.384]    [Pg.418]    [Pg.228]    [Pg.235]    [Pg.16]    [Pg.249]    [Pg.363]    [Pg.244]    [Pg.93]    [Pg.71]    [Pg.49]    [Pg.52]    [Pg.742]    [Pg.146]    [Pg.69]    [Pg.524]    [Pg.642]    [Pg.290]    [Pg.54]    [Pg.434]    [Pg.58]    [Pg.102]    [Pg.68]    [Pg.82]    [Pg.122]   
See also in sourсe #XX -- [ Pg.318 , Pg.710 ]




SEARCH



Feature Trees Theory and Applications from Large-scale Virtual Screening to Data Analysis

Virtual screening detailed analysis

Virtual screening molecular similarity analysis

© 2024 chempedia.info