Transient maximum

Theoretical calculations have shown that the current transient after an initial rise passes through several oscillations, and after deposition of a limited number of layers levels out to a final steady state value. Oscillations very closely resembling this description have been observed on dislocation-free Ag (100) faces. Fig. 5.24. In Fig. 5.25 theoretical and experimental current transients are compared. All transients are normalized to the parameters of the current transient maximum of the first layer formation according to eq. (5.15) ... [Pg.232]

The relaxation and creep experiments that were described in the preceding sections are known as transient experiments. They begin, run their course, and end. A different experimental approach, called a dynamic experiment, involves stresses and strains that vary periodically. Our concern will be with sinusoidal oscillations of frequency v in cycles per second (Hz) or co in radians per second. Remember that there are 2ir radians in a full cycle, so co = 2nv. The reciprocal of CO gives the period of the oscillation and defines the time scale of the experiment. In connection with the relaxation and creep experiments, we observed that the maximum viscoelastic effect was observed when the time scale of the experiment is close to r. At a fixed temperature and for a specific sample, r or the spectrum of r values is fixed. If it does not correspond to the time scale of a transient experiment, we will lose a considerable amount of information about the viscoelastic response of the system. In a dynamic experiment it may... [Pg.173]

The operation of system valves (also starting and shutdown of pumps) has a significant effect on the transient fluid pressures in the piping system because of the acceleration and deceleration of the fluid as it changes its velocity. As a simple example, the maximum head rise caused by the instantaneous closing of a valve is given by... [Pg.58]

Data on duorescence, phosphorescence, excited-state lifetimes, transient absorption spectra, and dye lasers are tabulated in Ref. 16. The main nonduorescent process in cyanine dyes is the radiationless deactivation Sj — Sg. Maximum singlet-triplet interconversion ( 52 ) methanol for carbocyanines is about 3% (maxLgrp > 0.03), and the sum [Lpj + st] I than 0.10. [Pg.398]

ERPG-l The maximum airborne concentration below which it is believed that nearly all individuals coiild be exposed for up to one hour without experiencing other than mild transient adverse health effects or perceiving a clearly defined objectionable odor. [Pg.2273]

Looking at these sources from an algal perspective, evolution in habitats in which soluble sources are deficient or, at best, transiently present in time as well as in space, has provided them with mechanisms to take up soluble phosphorus at rapid rates from low concentrations. Most can satisfy their growth needs at SRP concentrations well below 10 molar, even though maximum uptake... [Pg.33]

The magnitudes of fault currents under different conditions of fault are analysed in Table 13.9. Figure 14.5 has been redrawn in Figure 13.20 for a generator circuit illustrating the sub-transient, transient and steady-state currents on an actual fault. The curve depicts the most severe fault condition which occurs when the circuit voltage is the minimum, i.e. at Vq, causing the maximum asymmetry atid the associated d.c. component. [Pg.354]

In certain cases, where a long delay may be necessary for the protective scheme to operate, it may be desirable to use the maximum steady-state short-circuit current V2 /j, for a more appropriate setting, rather than the maximum transient current i2 /, as by then the fault current will also fall to a near steady-state value, /sKr.m s.i-... [Pg.355]

Magnitude of the first peak current (fy) Maximum transient current 2 (or Iqq)... [Pg.356]

Table 13.11 Multiplying factors to obtain the momentary peak (maximum r.m.s. or dynamic) values of the short-circuit currents including the sub-transient d.c. component at different power factors (FI/Xl)... Table 13.11 Multiplying factors to obtain the momentary peak (maximum r.m.s. or dynamic) values of the short-circuit currents including the sub-transient d.c. component at different power factors (FI/Xl)...
Direct-reading polychromators (Figure 3b) have a number of exit slits and photomultiplier tube detectors, which allows one to view emission from many lines simultaneously. More than 40 elements can be determined in less than one minute. The choice of emission lines in the polychromator must be made before the instrument is purchased. The polychromator can be used to monitor transient signals (if the appropriate electronics and software are available) because unlike slew-scan systems it can be set stably to the peak emission wavelength. Background emission cannot be measured simultaneously at a wavelength close to the line for each element of interest. For maximum speed and flexibility both a direct-reading polychromator and a slew-scan monochromator can be used to view emission from the plasma simultaneously. [Pg.641]


See other pages where Transient maximum is mentioned: [Pg.76]    [Pg.150]    [Pg.88]    [Pg.104]    [Pg.209]    [Pg.1521]    [Pg.2039]    [Pg.385]    [Pg.388]    [Pg.307]    [Pg.258]    [Pg.273]    [Pg.102]    [Pg.76]    [Pg.150]    [Pg.88]    [Pg.104]    [Pg.209]    [Pg.1521]    [Pg.2039]    [Pg.385]    [Pg.388]    [Pg.307]    [Pg.258]    [Pg.273]    [Pg.102]    [Pg.885]    [Pg.87]    [Pg.1286]    [Pg.257]    [Pg.337]    [Pg.193]    [Pg.529]    [Pg.83]    [Pg.83]    [Pg.1741]    [Pg.2291]    [Pg.2486]    [Pg.431]    [Pg.558]    [Pg.573]    [Pg.581]    [Pg.869]    [Pg.231]    [Pg.255]    [Pg.277]    [Pg.544]    [Pg.122]    [Pg.90]    [Pg.334]    [Pg.216]   