Generators circuits

The magnitudes of fault currents under different conditions of fault are analysed in Table 13.9. Figure 14.5 has been redrawn in Figure 13.20 for a generator circuit illustrating the sub-transient, transient and steady-state currents on an actual fault. The curve depicts the most severe fault condition which occurs when the circuit voltage is the minimum, i.e. at Vq, causing the maximum asymmetry atid the associated d.c. component. [Pg.354]

Switchgear and controlgear assemblies 13/355 Table 13.9 Fault currents (r.m.s.) in a generator circuit under different fault conditions... [Pg.355]

Normally only a 1-second system is in use. The 3-second system is severe, for which protective devices in certain ratings may not be possible or may become prohibitively costlier to prvivluce. The 3-sceond system may. however, be used for a generator circuit to protect the generating. source from a fallout on a fault elsewhere in the system. [Pg.367]

Short circuit generator Circuit breaker H.T. transformer Master breaker... [Pg.429]

The supply system for the power plant auxiliaries, including the provision of supplies to any important drives and the provision of standby supply systems. The protection and synchronizing schemes applicable to the generator circuit. [Pg.190]

Staircase generator circuits have important applications in video systems. There are several ways to generate staircase waveforms, using... [Pg.208]

The schematic of the staircase generator circuit is shown in Fig. 7.18. Not shown in the schematic is the power to the JK flip-flops and the AND gate. A +5-V DC input was used to power the digital ICs. [Pg.209]

The staircase generator circuit was constructed in all three simulators and in the lab by using real components. The breadboard used a... [Pg.210]

In the circuit of Figure 8.3b, a fixed resistance Rr is used in the input current-generating circuit. Since this same current passes through Ru and the operational amplifier maintains point S at the common potential, the output voltage e0 is equal to -iRu. From... [Pg.246]

Meyrand P, Simmers J, Moulins M. 1991. Construction of a pattern-generating circuit with neurons of different networks. Nature 351 60-63. [Pg.114]

Here is a model of a parameterized N-bit parity generator circuit. The model provides both an odd parity and an even parity output. [Pg.141]

Electrometric methods are employed to detect the end points of conventional titrations, as well as those of the coulometric titrations described in Section 11.4. These detection methods typically involve two small electrodes in an indicator circuit that is electrically separate from the generating circuit that would be present for a coulometric titration. All electrometric methods are based on measurements of either the potential difference between the two electrodes in the indicator circuit (potentiometric methods) or the current passing in that circuit (amperometric methods). Further classification is based on the... [Pg.435]

Each light quantum effective in Reaction 1 eventually produces a second e aq via Reactions 2 and 3 (7), but scavengers such as 02, when present even in submicromolar concentrations, profoundly affect its formation and decay. To eliminate them we preirradiate our solutions with a second ultraviolet mercury lamp. After cleanup we can inject scavengers at micro- and submicromolar levels. During preirradiation and after the injection of samples, the solution in the cell is mixed by means of a small glass-encased iron rod, activated by a solenoid that receives repetitive pulses from a pulse-generating circuit. [Pg.273]

Situations occur, especially with offshore platforms, where no physical space is available to install an extra generator and its associated equipment. Sometimes the main switchrooms cannot accept any more switchgear, not even one more generator circuit breaker. Therefore the potential for upgrading a prime mover without having to make major changes to the electrical system is an option that should be considered seriously at the beginning of a project. [Pg.15]

To protect the system from prolonged high voltage it is the usual practice to install an overvoltage relay (59) in each of the generator circuit breakers or at their common busbar. The relay settings are usually set to operate at 115%, with a time delay between 0.5 and 10.0 seconds. [Pg.324]

Skill 13.3 Describe the effects and applications of electromagnetic forces in real-life situations, including electric power generation, circuit breakers, and brownouts. [Pg.93]


See other pages where Generators circuits is mentioned: [Pg.352]    [Pg.515]    [Pg.671]    [Pg.269]    [Pg.189]    [Pg.191]    [Pg.239]    [Pg.5]    [Pg.668]    [Pg.140]    [Pg.173]    [Pg.117]    [Pg.119]    [Pg.321]    [Pg.173]    [Pg.433]    [Pg.404]    [Pg.322]    [Pg.223]    [Pg.145]    [Pg.277]    [Pg.436]    [Pg.437]    [Pg.438]    [Pg.448]    [Pg.30]    [Pg.220]    [Pg.126]    [Pg.257]   