Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Detectors photomultiplier tubes

The emission of the excited analytes in the plasma is polychromatic (several different wavelengths per analyte). The spectrophotometers used to detect and quantify the emitted radiation contain a monochromator (polychromator for simultaneous measurements at several different wavelengths) and a detector (photomultiplier tube) to quantify the amount of radiation for each specific wavelength. [Pg.528]

Detector photomultiplier tube thermal, pyroelectric, bolometers... [Pg.211]

Scintillators are also used in the detectors of CT scanners. Here an electronic detector, the photomultiplier tube, is used to produce an electrical signal from the visible and ultraviolet light photons. These imaging systems typically need fast scintillators with a high efficiency. [Pg.50]

Fig. 14-4. Schematic diagram of chemiluminescent detector for NO2 and NO. PMT, photomultiplier tube. Fig. 14-4. Schematic diagram of chemiluminescent detector for NO2 and NO. PMT, photomultiplier tube.
An optical detector with appropriate electronics and readout. Photomultiplier tubes supply good sensitivity for wavelengths in the visible range, and Ge, Si, or other photodiodes can be used in the near infrared range. Multichannel detectors like CCD or photodiode arrays can reduce measurement times, and a streak camera or nonlinear optical techniques can be used to record ps or sub-ps transients. [Pg.383]

Figura 3 Grating spectrometers commonly used for ICP-OES (a) monochromator, in which wavelength is scanned by rotating the grating while using a singie photomultiplier tube (PMT) detector (b) polychromator, in which each photomultiplier observes emission from a different wavelength (40 or more exit slits and PMTs can be arranged along the focal plane) and (c) spectrally segmented diode-array spectrometer. Figura 3 Grating spectrometers commonly used for ICP-OES (a) monochromator, in which wavelength is scanned by rotating the grating while using a singie photomultiplier tube (PMT) detector (b) polychromator, in which each photomultiplier observes emission from a different wavelength (40 or more exit slits and PMTs can be arranged along the focal plane) and (c) spectrally segmented diode-array spectrometer.
Direct-reading polychromators (Figure 3b) have a number of exit slits and photomultiplier tube detectors, which allows one to view emission from many lines simultaneously. More than 40 elements can be determined in less than one minute. The choice of emission lines in the polychromator must be made before the instrument is purchased. The polychromator can be used to monitor transient signals (if the appropriate electronics and software are available) because unlike slew-scan systems it can be set stably to the peak emission wavelength. Background emission cannot be measured simultaneously at a wavelength close to the line for each element of interest. For maximum speed and flexibility both a direct-reading polychromator and a slew-scan monochromator can be used to view emission from the plasma simultaneously. [Pg.641]

Flame Photometric Detector3 With the flame photometric detector (FPD), as with the FID, the sample effluent is burned in a hydrogen/air flame. By using optical filters to select wavelengths specific to sulfur and phosphorus and a photomultiplier tube, sulfur or phosphorus compounds can be selectively detected. [Pg.11]

The main detectors used in AES today are photomultiplier tubes (PMTs), photodiode arrays (PDAs), charge-coupled devices (CCDs), and vidicons, image dissectors, and charge-injection detectors (CIDs). An innovative CCD detector for AES has been described [147]. New developments are the array detector AES. With modem multichannel echelle spectral analysers it is possible to analyse any luminous event (flash, spark, laser-induced plasma, discharge) instantly. Considering the complexity of emission spectra, the importance of spectral resolution cannot be overemphasised. Table 8.25 shows some typical spectral emission lines of some common elements. Atomic plasma emission sources can act as chromatographic detectors, e.g. GC-AED (see Chapter 4). [Pg.614]

The experiment is performed with a spectrofluorometer similar to the ones used for linear fluorescence and quantum yield measurements (Sect. 2.1). The excitation, instead of a regular lamp, is done using femtosecond pulses, and the detector (usually a photomultiplier tube or an avalanche photodiode) must either have a very low dark current (usually true for UV-VIS detectors but not for the NIR), or to be gated at the laser repetition rate. Figure 11 shows a simplified schematic for the 2PF technique. [Pg.124]

In conventional chip experiments, fluorescence scanners are used for chip read-out. In the case of laser scanners, HeNe lasers are used as excitation sources and photomultiplier tubes as detectors, whereas CCD-based scanners use white light sources. The optical system can be confocal or non-confocal. Standard biochip experiments are performed using two fluorescent labels as... [Pg.492]

The secondary electrons emitted from the sample are attracted to the detector by the collector screen. Once near the detector, the secondary electrons are accelerated into the scintillator by a positive potential maintained on the scintillator. Visible light is produced by the reaction of the secondary electrons with the scintillator material. The emitted light is detected by a photomultiplier tube, which is optically coupled to the scintillator via a light pipe. The PMT signal is then transferred to the grid of a cathode ray tube (CRT). Data collection... [Pg.145]


See other pages where Detectors photomultiplier tubes is mentioned: [Pg.268]    [Pg.698]    [Pg.137]    [Pg.25]    [Pg.200]    [Pg.268]    [Pg.698]    [Pg.137]    [Pg.25]    [Pg.200]    [Pg.1120]    [Pg.1164]    [Pg.1379]    [Pg.1436]    [Pg.2486]    [Pg.3028]    [Pg.196]    [Pg.208]    [Pg.57]    [Pg.419]    [Pg.481]    [Pg.317]    [Pg.376]    [Pg.224]    [Pg.267]    [Pg.258]    [Pg.41]    [Pg.223]    [Pg.663]    [Pg.664]    [Pg.808]    [Pg.344]    [Pg.303]    [Pg.606]    [Pg.620]    [Pg.110]    [Pg.326]    [Pg.576]    [Pg.123]    [Pg.100]    [Pg.164]    [Pg.165]    [Pg.135]    [Pg.180]   
See also in sourсe #XX -- [ Pg.219 ]

See also in sourсe #XX -- [ Pg.625 , Pg.626 ]




SEARCH



Detector photomultiplier

Photomultiplier

Photomultiplier tube particle detector

Photomultiplier tubes

Photomultipliers

Photomultipliers detectors

Scintillation detectors photomultiplier tubes

© 2024 chempedia.info