Thermal ratios

Heat exchanger Effectiveness (or thermal ratio) e = Temperature rise (cold side (/maximum temperature difference between entry (hot side) and entry (cold side)... [Pg.33]

At higher frequencies, the laser-Raman effect affords, in principle, the possibility of detecting non-thermal excitation of vibrations. These would be found from a higher than thermal ratio of anti-Stokes to Stokes lines. The Raman effect in biological systems has recently been reviewed by Webb (21). Unfortunately only two relevant measurements have been carried out, so far, but both demonstrate non-thermal excitation. A difficulty affecting reproducibility arises here from the effect of a laser beam on a biological system as discussed in (21), in the case of individual cells. The best way to avoid this appears to be the use of a flow instrumentation so that each cell is subjected to the laser beam for a very short period only (22). [Pg.217]

Tbe ttU-range Monte Carlo program RECAP has been used in a consistent analysis of physics parameters measured in seven HtO-moderated uranium lattices. The motivation has been to test input nuclear data, which cmistitute the major source of uncertainty. The fi owing parameters are considered epithermal-to-thermal ratio for U capture (p ) and for tJ fission (6 ), ratio of -fission-to- fission and eigmivalne... [Pg.232]

The Ft correction factor is usually correlated in terms of two dimensionless ratios, the ratio of the two heat capacity flow rates R and the thermal effectiveness P of the exchanger ... [Pg.223]

Seeley J V, Morris R A, Viggiano A A, Wang FI and Flase W L 1997 Temperature dependencies of the rate constants and branching ratios for the reactions of Cr(Fl20)g 3 with CFIjBr and thermal dissociation rates for CI (CFl3Br) J. Am. Chem. Soc. 119 577-84... [Pg.825]

The thermal conductivity of polymeric fluids is very low and hence the main heat transport mechanism in polymer processing flows is convection (i.e. corresponds to very high Peclet numbers the Peclet number is defined as pcUUk which represents the ratio of convective to conductive energy transport). As emphasized before, numerical simulation of convection-dominated transport phenomena by the standard Galerkin method in a fixed (i.e. Eulerian) framework gives unstable and oscillatory results and cannot be used. [Pg.90]

Thermal energy in flame atomization is provided by the combustion of a fuel-oxidant mixture. Common fuels and oxidants and their normal temperature ranges are listed in Table 10.9. Of these, the air-acetylene and nitrous oxide-acetylene flames are used most frequently. Normally, the fuel and oxidant are mixed in an approximately stoichiometric ratio however, a fuel-rich mixture may be desirable for atoms that are easily oxidized. The most common design for the burner is the slot burner shown in Figure 10.38. This burner provides a long path length for monitoring absorbance and a stable flame. [Pg.413]

The ion current resulting from collection of the mass-separated ions provides a measure of the numbers of ions at each m/z value (the ion abundances). Note that for this ionization method, all ions have only a single positive charge, z = 1, so that m/z = m, which means that masses are obtained directly from the measured m/z values. Thus, after the thermal ionization process, m/z values and abundances of ions are measured. The accurate measurement of relative ion abundances provides highly accurate isotope ratios. This aspect is developed more fully below. [Pg.46]

El = electron ionization Cl = chemical ionization ES = electrospray APCI = atmospheric-pressure chemical ionization MALDI = matrix-assisted laser desorption ionization PT = plasma torch (isotope ratios) TI = thermal (surface) ionization (isotope ratios). [Pg.280]

Plasma torches and thermal ionization sources break down the substances into atoms and ionized atoms. Both are used for measurement of accurate isotope ratios. In the breakdown process, all structural information is lost, other than an identification of elements present (e.g., as in inductively coupled mass spectrometry, ICP/MS). [Pg.285]

Since detailed chemical structure information is not usually required from isotope ratio measurements, it is possible to vaporize samples by simply pyrolyzing them. For this purpose, the sample can be placed on a tungsten, rhenium, or platinum wire and heated strongly in vacuum by passing an electric current through the wire. This is thermal or surface ionization (TI). Alternatively, a small electric furnace can be used when removal of solvent from a dilute solution is desirable before vaporization of residual solute. Again, a wide variety of mass analyzers can be used to measure m/z values of atomic ions and their relative abundances. [Pg.285]

Almost any kind of ion source could be used, but, again, in practice only a few types are used routinely and are often associated with the method used for sample introduction. Thus, a plasma torch is used most frequently for materials that can be vaporized (see Chapters 14-17 and 19). Chapter 7, Thermal Ionization, should be consulted for another popular method in accurate isotope ratio measurement. [Pg.366]

Accurate, precise isotope ratio measurements are important in a wide variety of applications, including dating, examination of environmental samples, and studies on drug metabolism. The degree of accuracy and precision required necessitates the use of special isotope mass spectrometers, which mostly use thermal ionization or inductively coupled plasma ionization, often together with multiple ion collectors. [Pg.369]

Thermal ionization has three distinct advantages the ability to produce mass spectra free from background interference, the ability to regulate the flow of ions by altering the filament temperature, and the possibility of changing the filament material to obtain a work function matching ionization energies. This flexibility makes thermal ionization a useful technique for the precise measurement of isotope ratios in a variety of substrates. [Pg.389]

Thermal or surface emission of ions is one of the oldest ionization techniques used for isotope ratio measurements. [Pg.389]

The ablated vapors constitute an aerosol that can be examined using a secondary ionization source. Thus, passing the aerosol into a plasma torch provides an excellent means of ionization, and by such methods isotope patterns or ratios are readily measurable from otherwise intractable materials such as bone or ceramics. If the sample examined is dissolved as a solid solution in a matrix, the rapid expansion of the matrix, often an organic acid, covolatilizes the entrained sample. Proton transfer from the matrix occurs to give protonated molecular ions of the sample. Normally thermally unstable, polar biomolecules such as proteins give good yields of protonated ions. This is the basis of matrix-assisted laser desorption ionization (MALDI). [Pg.399]

With such mass spectrometers, plasma torches and thermal ionization are the most widely used means for ionizing samples for ratio measurements. [Pg.425]

Acrylonitrile copolymeri2es readily with many electron-donor monomers other than styrene. Hundreds of acrylonitrile copolymers have been reported, and a comprehensive listing of reactivity ratios for acrylonitrile copolymeri2ations is readily available (34,102). Copolymeri2ation mitigates the undesirable properties of acrylonitrile homopolymer, such as poor thermal stabiUty and poor processabiUty. At the same time, desirable attributes such as rigidity, chemical resistance, and excellent barrier properties are iacorporated iato melt-processable resias. [Pg.196]

Staged reactions, where only part of the initial reactants are added, either to consecutive reactors or with a time lag to the same reactor, maybe used to reduce dipentaerythritol content. This technique increases the effective formaldehyde-to-acetaldehyde mole ratio, maintaining the original stoichiometric one. It also permits easier thermal control of the reaction (66,67). Both batch and continuous reaction systems are used. The former have greater flexibiHty whereas the product of the latter has improved consistency (55,68). [Pg.465]


See other pages where Thermal ratios is mentioned: [Pg.114]    [Pg.80]    [Pg.771]    [Pg.114]    [Pg.80]    [Pg.771]    [Pg.198]    [Pg.299]    [Pg.1110]    [Pg.210]    [Pg.20]    [Pg.169]    [Pg.170]    [Pg.197]    [Pg.131]    [Pg.534]    [Pg.353]    [Pg.92]    [Pg.122]    [Pg.222]    [Pg.262]    [Pg.285]    [Pg.300]    [Pg.301]    [Pg.287]    [Pg.287]    [Pg.318]    [Pg.428]    [Pg.42]    [Pg.99]    [Pg.99]    [Pg.282]   
See also in sourсe #XX -- [ Pg.33 ]

See also in sourсe #XX -- [ Pg.68 ]