Temperature Modes

Because of its small size and portabiHty, the hot-wire anemometer is ideally suited to measure gas velocities either continuously or on a troubleshooting basis in systems where excess pressure drop cannot be tolerated. Furnaces, smokestacks, electrostatic precipitators, and air ducts are typical areas of appHcation. Its fast response to velocity or temperature fluctuations in the surrounding gas makes it particularly useful in studying the turbulence characteristics and rapidity of mixing in gas streams. The constant current mode of operation has a wide frequency response and relatively lower noise level, provided a sufficiently small wire can be used. Where a more mgged wire is required, the constant temperature mode is employed because of its insensitivity to sensor heat capacity. In Hquids, hot-film sensors are employed instead of wires. The sensor consists of a thin metallic film mounted on the surface of a thermally and electrically insulated probe. [Pg.110]

Reference Acceptor passivated and cone, in cm-3 Mode of hydrogenation and temperature Mode of measurement of passivation Distinctness of plateau... [Pg.301]

To prevent the latter mentioned subsequent reactions, the bulky phos-phaalkyne Ph C P as well as tungsten alkoxides of reduced size as, e.g., [W2(ONp)6] were employed in these three-component reactions with no significant success [15]. The crucial steps for the side-product free synthesis of the phosphido complexes 18 are the introduction of a phosphaalkyne possessing a moderate steric bulkiness, which lies between those of f-BuC=P and Ph C P, and resulting from the P-NMR studies (cf. Eq. 5), a reaction temperature mode allowing the complete metathesis reaction to take place at very low temperatures over a long period of time until all the phosphaalkyne has been converted into the metathesis products (about 12 h) only then is the reaction mixture allowed to reach room temperature. We found that MesC=P meets these steric requirements, and the three-component-reaction between MesC=P, [W2(Of-Bu)6] and [M(CO)5(thf)] (M = Cr, W), carried out at -78 °C and warmed up to ambient temperature within 15 h, succeeded in the synthesis and isolation of the phosphido complex 18a,b (Scheme 2) [15]. Furthermore, if t-BuC=P is incorporated into these reactions, the steric requirements of the alkoxide dimer has to be slightly increased. Thus, f-BuC=P reacts with [W2(OPh )6] and [M(CO)5(thf)] (M=Cr, W) under the... [Pg.14]

Besides the currently used constant temperature mode it has been reported that temperature oscillation can enhance cell viability of Sf9 insect cells and ba-culovirus production of occlusion bodies (OB) and extracellular virus (ECV) compared with constant temperature in stationary culture and suspension culture, with the optimal oscillation range at 24-28°C [82]. As a curiosity Pham et al. found that, by raising the infection temperature to 30 °C, they more than doubled the protein productivity of human interleukin-2 (IL-2), in insect larvae, Trichoplusia ni [83]. [Pg.196]

An alternative mechanism for nitroxyl radical production analogous to one of the higher temperature modes of R02 destruction is ... [Pg.218]

The application of arylpyruvic acids 256 in place of pyruvic acid in three-component reactions leads to dramatic changes in the direction of the process. Refluxing of starting compounds for 3 hours of irradiating with microwave at 170°C for 20 minutes in acetic acid yielded 3-hydroxy-4,5-diaryl-l-azolyl-2,5-dihydro-li/-2-pyrrolones 258 [203] (Scheme 3.73). Under ultrasonic irradiation in ethanol with the addition of catalytic amounts of hydrochloric acid or in acetic acid, the reaction proceeds in a different direction with the formation of pyrimidinecarboxylic acids 259. In the case of pyruvic acid the course of the three-component reaction does not so drastically depend on the activation method or solvent type as well as from temperature mode [202]. [Pg.100]

Lamb, J. D. and Smith, R. G. (1992) A Comparison of Gradient Capacity Anion Chromatography Using Macrocycles D-2.2.2 and D-2.2.1 in Constant or Variable Temperature Mode, Talanta 39, 923-930. [Pg.360]

The low energy excitation is observed at finite frequencies only for T In moderate magnetic fields its frequency is increasing as shown in Fig. 2d). Such a shift of the low temperature mode and the order parameter-like dependence on temperature has been taken as evidence that the mode cannot be related to a singlet state and must be identified as a longitudinal magnon [33, 34],... [Pg.178]

Numerous new modes emerge below Tc in the FIR [28-32] and Raman [33-37] spectra of a -NaV205. Fig. 8 presents FIR polarized transmittance in a spectral range from 55 to 350 cm 1 at temperatures above and below Tc. Arrows show new low-temperature modes. Some of them clearly split into doublets (see inset of Fig 8). The number and polarization properties of all the observed new LT modes in a -NaV205 can be reasonably described within the conception of folded vibrational modes of the dimerized Fmm2 crystal structure. Observed FIR doublets and close frequencies in different polarizations are naturally explained by their origin from the Q-point quadruplets folded into the zone center [30]. [Pg.225]

Figure 8. Transmission spectra of a -NaVOs at T 40K>TC (dashed line) and T=8K Figure 8. Transmission spectra of a -NaVOs at T 40K>TC (dashed line) and T=8K<TC (solid line) in E a, E b, and E c polarizations of the incident light with k c [(a) and (b)] and k a (c). The sample thicknesses were 14pm [(a) and (b)] and 150pm (c). Arrows show new low-temperature modes below Tc. Inset shows the line near 127cm"1 at different temperatures.
At the given residual pressure the distillation is carried out in the following temperature mode (°C, in vapour) ... [Pg.184]

For the developed mathematical model of HHP alternative calculations have been carried out with the purpose of search of optimum values of regime parameters for concrete installations [7, 8], It has been determined, that there are optimum initial pressure in sorbers of HHP, optimum temperature modes (at levels of temperatures Th, Tm, T ), providing the maximal efficiency. Optimization of control by HHP operation it is possible to achieve optimum characteristics of capacity and to choose necessary duration of a cycle of HHP. Control of the hydride heat pump is its essential part and as show the carried out calculations [7, 8], essentially influences efficiency of its operation. Experimental results basically have proved mathematical calculations. [Pg.858]

As antiscuff, anti-wear properties of additives depend on the covalent-bonded sulfur contents, the selection of optimum conditions to effect sulfuring processes has been set with introducing the greatest amount possible of covalent sulfur. For this purpose functionalizing of diene and olefin hydrocarbons was conducted on a wide time-temperature mode. Considering that the temperature of boiling pipeiylene fraction low (42-44°C), sulfuring was carried out in a constantly temperature-controlled autoclave in the presence of the catalyst cobalt phthalocyanine [3], in the medium of non-polar solvents (for example, heptane). Under... [Pg.53]

MAS is routinely used in solid-state NMR spectroscopy for eliminating the elfects of chemical shift anisotropy, heteronuclear dipolar interactions and first-order quadrupolar interactions. In this method the sample is rotated abont the axis inclined at 54.74° with respect to the external magnetic field Bo, so that the average of the geometric term in nnclear spin interactions (3cos 0 — 1) = Except for some specific applications of static wide-line solid-state NMR spectroscopy (i.e., for or for the determination of CSA patterns), the MAS is an essential feature of solid-state NMR spectroscopy and can also be nsed in variable temperature mode. The MAS methodology can also be nsed for high-resolntion studies of viscous hquids and soft solids. [Pg.6166]

The temperature mode, in which US is applied until the sample reaches a given temperature and... [Pg.22]

The currently available ultrasonic probes and baths are equipped with temperature control. There is an operational working alternative, partioularly with US-probes, that is called temperature mode and involves applying US only until the sample reaches a preset temperature. [Pg.73]

Fig. 70. Dynamics of phase fonnation during combustion reaction between titanium and air in high-temperature mode (Adapted from Khomenko et al., 1993). Fig. 70. Dynamics of phase fonnation during combustion reaction between titanium and air in high-temperature mode (Adapted from Khomenko et al., 1993).
Thermally-activated peroxide initiated polymerizations were performed in the normal scanning temperature mode (+20° min"J, 40 mm min I chart speed) with the unmodified DSC-2 apparatus. The scan baseline was obtained by a second scan of the reacted material. Temperature range 30O-250°C. The curve area integrations... [Pg.91]

In depth discussions of the TCD can be found in most texts on gas chromatography [1-4]. Lawson and Miller [5] have written a review of the TCD, and give multiple references to discussions regarding the TCD. A comparison of the various modes of operation has been made by Wells and Simon [6] which compares the constant voltage, constant current, and constant mean temperature modes of operation on both an empirical and a theoretical basis. [Pg.60]

The small volume thermal conductivity detector used In this study was a Y-type [ 10,11,12] gas flow pattern 30 Cow-Mac Model 10-955 cell (Gow-Mac Instrument Company, Madison, New Jersey). This cell was compared with the standard Varlan TCD (Gow-Mac Model 10-952) In a Varlan series 3700 gas chromatograph. The standard electronics were modified for operation with the 30 pi TCD. All measurements were made In the constant mean temperature mode. The carrier gas was He. The flow rates were regulated by two 0-60 ml/mln mass flow controllers (model 1000, Porter Instrument Company, Hatfield, Fa.) or by a pressure regulator (Model 8601, Brooks Instrument Division, Emerson Electric Company, Hatfield, Pa.). The capillary column was attached to a modified 1/16 to 1/16 Swagelok union which In turn was connected to the appropriate TCD. All make-up flows were regulated so that the total flow through both the reference and the sample sides were matched. [Pg.64]


See other pages where Temperature Modes is mentioned: [Pg.67]    [Pg.549]    [Pg.244]    [Pg.86]    [Pg.86]    [Pg.104]    [Pg.13]    [Pg.200]    [Pg.209]    [Pg.136]    [Pg.30]    [Pg.392]    [Pg.221]    [Pg.897]    [Pg.206]    [Pg.256]    [Pg.28]    [Pg.108]    [Pg.174]    [Pg.174]    [Pg.787]    [Pg.235]    [Pg.317]    [Pg.158]    [Pg.159]    [Pg.65]    [Pg.378]   
See also in sourсe #XX -- [ Pg.307 , Pg.308 ]