Temperature limit device

Nonlinear and discontinuous equations can be easily implemented, e.g., to simulate the effects of a temperature-limiting device or a digital voltmeter. ... [Pg.41]

Temperature Limit Devices According to the Boyle-Charles Law, gas pressure will increase and decreases in closed containers as content temperatures rise and fall. Processes and containers where exceeding pressure limits create dangers may incorporate temperature limit sensors and special controls to minimize the dangers from temperature changes. [Pg.282]

As the density of devices placed on the silicon wafer increases, the problems of autodoping and interdiffusion become more acute and the high temperature limitation of the above reactions has prompted much experimental effort to develop epitaxial deposition at lower temperature. This has been accomplished in the following experimental developments ... [Pg.221]

An important consideration in the sequence of semiconductor devices fabrication is the so-called thermal budget, a measure of both the CVD temperature and the time at that temperature for any given CVD operation. As a rule, the thermal budget becomes lower the farther away a given step is from the original surface of the silicon wafer. This restriction is the result of the temperature limitations of the already deposited materials. [Pg.351]

Bulk property detectors function by measuring some bulk physical property of the mobile phase, e.g., thermal conductivity or refractive index. As a bulk property is being measured, the detector responses are very susceptible to changes in the mobile phase composition or temperature these devices cannot be used for gradient elution in LC. They are also very sensitive to the operating conditions of the chromatograph (pressure, flow-rate) [31]. Detectors such as TCD, while approaching universality in detection, suffer from limited sensitivity and inability to characterise eluate species. [Pg.178]

A novel microhotplate design was proposed to overcome the CMOS operating temperature limit and to avoid polysilicon-induced drift problems. A cross-sectional schematic of the device is shovm in Fig. 4.11. Instead of using a polysilicon resistor as temperature sensor, a platinum temperature sensor is patterned on the microhotplate. The Pt-metallization process step was used to simultaneously fabricate the electrodes and the temperature sensor. The CMOS-Al/Pt contacts are located off the membrane... [Pg.44]

One approach which does not utilize a confining fluid has been developed by Saylak (83). This technique involves an optical system which continuously monitors the lateral strain in a uniaxial specimen. The specimen must be circular in cross section, and the volume change computation requires uniform dewetting throughout the sample. This method is not rate and temperature limited since no mechanical attachments or fluids are in contact with the sample. A schematic of the lateral strain device is shown in Figure 13. Surland and Givan (104) also describe an... [Pg.209]

Accuracy of thermocouples should be 0.5°C. Temperature accuracy is especially important in steam sterilization validation because an error of just 0.1 °C in temperature measured by a faulty thermocouple will produce a 2.3% error in the calculated F0 value. Thermocouple accuracy is determined using National Bureau of Standards (NBS) traceable constant temperature calibration instruments such as those shown in Figure 6. Thermocouples should be calibrated before and after a validation experiment at two temperatures 0°C and 125°C. The newer temperature-recording devices are capable of automatically correcting temperature or slight errors in the thermocouple calibration. Any thermocouple that senses a temperature of more than 0.5°C away from the calibration temperature bath should be discarded. Stricter limits (i.e., <0.5°C) may be imposed according to the user s experience and expectations. Temperature recorders should be capable of printing temperature data in 0.1 °C increments. [Pg.138]

Direct heating thermal rockets are distinguished from heat transfer thermal rockets in that the energy transfer does not occur through a material wall. Such devices include the arcjet, which already has been mentioned, liquid and gaseous core nuclear rockets, and nuclear bomb propulsion. Most of the previous discussion applies directly to the selection of a propellant for an arcjet propulsion device. In reality even the arcjet performance is temperature limited--except in this case the propellant acts to heat the wall rather than the reverse. [Pg.116]

The US EPA defined Best Current Operating Practice (BOP) as being the use of GCP combined with a temperature limitation of 350 °F (approximately 175 °C) on the inlet to post-combustion control devices. Rapid quenching of the combustion gases to below 175 °C was also regarded as BOP. [Pg.162]

Molders utilizing this system require equipment to measure and control the amount of entrained gas in the liquid at the desired level. They can include mass flow meters with density devices, nuclear density monitoring devices, as well as a variety of other densities measuring devices to control nucleation level. All these systems work within very defined pressure and temperature limits however, outside these limits, readings become erratic. There are systems that remove the dependence on system pressure and temperature. This system provides more consistent data. [Pg.417]

Additional requirements for q-apparatus, e.g. for means of closing, cable entries and bushings, protective devices for temperature limitation, type and routine verifications and tests, are specified in the q-standards. [Pg.133]

Because heat-transfer equipment for solids is generally an adaptation of a primarily material-handling device, the area of heat transfer is often small in relation to the overall size of the equipment. Also peculiar to solids heat transfer is that the At varies for the different heat-transfer mechanisms. With a knowledge of these mechanisms, the At term generally is readily estimated from temperature limitations imposed by the burden characteristics and/or the construction. [Pg.877]


See other pages where Temperature limit device is mentioned: [Pg.108]    [Pg.108]    [Pg.12]    [Pg.59]    [Pg.92]    [Pg.464]    [Pg.400]    [Pg.468]    [Pg.1091]    [Pg.243]    [Pg.578]    [Pg.776]    [Pg.598]    [Pg.231]    [Pg.15]    [Pg.10]    [Pg.78]    [Pg.78]    [Pg.97]    [Pg.135]    [Pg.464]    [Pg.400]    [Pg.122]    [Pg.468]    [Pg.103]    [Pg.205]    [Pg.92]    [Pg.12]    [Pg.59]    [Pg.21]    [Pg.306]    [Pg.197]    [Pg.50]    [Pg.290]    [Pg.111]    [Pg.914]    [Pg.222]   
See also in sourсe #XX -- [ Pg.282 ]




SEARCH



Limiting temperatures

Temperature device

Temperature limitations

Temperature limiter