During this phase the objectives of the system as well as the system performance specifications are identified. In addition, the technical and economic feasibility of the project is evaluated. [Pg.351]

Spot size. The size of the LGS is a critical issue, since it dehnes the saturation effects of the laser and the power needed to reach a given system performance, and also the quality of the wavefront sensing. There is an optimum diameter of the projector, because, if the diameter is too small, the beam will be spread out by diffraction and if it is too large it will be distorted due to atmospheric turbulence. The optimum diameter is about 3ro, thus existing systems use projection telescopes with diameters in the range of 30-50 cm. [Pg.221]

RCRA covers were constructed in 1995, and the ET covers were constructed in 1996. All of the covers are 43 ft wide by 328 ft long and were seeded with native vegetation. The purpose of the project is to use the performance data to help demonstrate equivalency and refine numerical models to more accurately predict cover system performance.39... [Pg.1085]

Typically a network of firewater systems mains is provided in a facility that form loops. These can be segregated into sections or legs and the performance of each can be determined by flow test. Flow tests release quantities of water that are measured and graphed. Performing an initial acceptance baseline test and recording the results from year to year can portray the performance of the firewater system and projections of the useful life of the system can be determined. [Pg.254]

Figure 11.2 Status of current technologies relative to key system performance and cost targets (Satyapal et al., 2006). Costs exclude regeneration and processing. Data are based on R D projections and independent analysis (FY05-FY06), and are updated periodically. Figure 11.2 Status of current technologies relative to key system performance and cost targets (Satyapal et al., 2006). Costs exclude regeneration and processing. Data are based on R D projections and independent analysis (FY05-FY06), and are updated periodically.
The qualification of the custom-built application must be performed according to normal software installation, operational and performance qualification practices. (Refer to Software Installation Qualification, System Operational Qualification, and System Performance Qualification in this chapter.) The following project activities depicted in Chapter 7 are applicable to custom-built systems ... [Pg.87]

The evaluation of computer systems performing regulated operations is the first phase to achieving an organized, prioritized, and balanced Part 11 Remediation Project approach. The objective of the evaluation is to identity the system s functional and/or procedural gaps results of the evaluation will determine whether the operational, maintenance, or security procedures specific to the system will provide a controlled environment, which ensures the integrity of the electronic records and/or signatures as stated in the Part 11 requirements. [Pg.132]

A contractor company represented in the DQO process by the project manager, the chemist, and the statistician will conduct project planning. The contractor company will provide the necessary resources and perform the work. The project budget and schedule are negotiable. A consulting company represented in the DQO process by the project manager and the chemist will perform the work the consultant will provide personnel for the operation of the treatment system. The project has a limited budget and will last for two years. [Pg.16]

As demonstrated in the previous section, it is advantageous to obtain a deeper understanding of how to perform projections and cuts for multicomponent reactive systems. A single projection or cut captures only part of the system under consideration. However, the user can form a mental picture of the phase diagram in its entirety by making a sequence of such projections and cuts [6],... [Pg.344]

ROSA [Reverse Osmosis System Analysis] 6 only projects reverse osmosis and nanofiltration system performance from a User-controlled set of data input and design decisions. The... [Pg.212]

Permeate back pressure must be taken into account when evaluating system performance. If not considered while running projections, actual performance will show a higher feed pressure than what was projected. Hence, if observed operating pressure is greater than predicted, review the projection to determine if permeate... [Pg.286]

Simply monitoring quality performance is just not adequate. The effectiveness of quality management systems should be actively managed and performance improvement opportunities seized. Business benefits should more than compensate for any investment in quality. Senior management, system owners, project managers, and anyone else involved with computer projects need to appreciate this. This book will help explain what needs to be done to successfully achieve quality and compliance of computer systems in the pharmaceutical and healthcare industries. [Pg.7]

Validation Plans record standards, methods, and personnel involved to assure quality through the system development life cycle and to establish the adequacy of the performance of the computer system. The term Validation Master Plan is typically used for large or multiple computer system validation projects. Validation planning should be initiated at the earliest practicable opportunity and may be reviewed and updated through subsequent stages of the project. [Pg.105]

Two separate test bums were conducted in accordance with the EPP to demonstrate that project emission limits could be met. First, sulfur hexafluoride (SF ), a thermally-stable surrogate, was injected and burned to optimize operating conditions and demonstrate thermal destruction efficiency and acid gas removal capabilities. Batches of frozen mustard were then processed under the optimized conditions to establish system performance for regulatory approval. The SF6 and mustard test bum results are summarized in Table 6.3. [Pg.98]

Figure 2.2. Schematic representation of the concept of total system performance assessment at Yucca Mountain, Nevada, USA. Source US Department of Energy Yucca Mountain Project web site (www.ymp.gov). Figure 2.2. Schematic representation of the concept of total system performance assessment at Yucca Mountain, Nevada, USA. Source US Department of Energy Yucca Mountain Project web site (www.ymp.gov).
Wc have omitted the six freciuencies corresponding to rotational and translational motions of the whole cluster. One of the advantages of the INM analysis is that we can perform projections of the density of states. One can decompose the density of states spectrum, c.g., into molecular rotational and translational motion [39]. For molecular clusters it is interesting to explore the localization of the motion described by the Hessian eigenvectors at different frequencies. Even though the harmonic motion is inherently collective, certain motions can be attributed to a limited area. This is the case of non-homogeneous systems, where the spectral characteristics can be quite different for different spatial parts. We define a projector Parea... [Pg.478]


See other pages where System performance projections is mentioned: [Pg.610]    [Pg.475]    [Pg.153]    [Pg.26]    [Pg.274]    [Pg.53]    [Pg.12]    [Pg.230]    [Pg.626]    [Pg.175]    [Pg.387]    [Pg.284]    [Pg.285]    [Pg.286]    [Pg.277]    [Pg.153]    [Pg.592]    [Pg.702]    [Pg.708]    [Pg.478]    [Pg.1027]    [Pg.476]    [Pg.175]    [Pg.265]    [Pg.688]    [Pg.11]    [Pg.277]    [Pg.13]   
See also in sourсe #XX -- [ Pg.286 ]

See also in sourсe #XX -- [ Pg.286 ]




SEARCH



Performance Projections

Projection systems

System Design and Performance Projections

System performance

© 2024 chempedia.info