Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Steady State Measurements

The value of the excited-state pK can be determined by fluorometric titration, but only when the equilibrium is established in the excited state. [Pg.105]

In the presence of photoinduced proton transfer, the steady-state fluorescence intensities are given by Eqs (4.55) and (4.56). In the absence of deprotoration (i.e. in a very acidic solution such that k i [H30+] 1/tq), when the experimental conditions (concentrations, excitation and observation wavelengths, sensitivity of the instrument) are kept strictly identical, the fluorescence intensities is (Iah )o = C o- Rewriting Eqs (4.55) as fAH = C , the following ratio is obtained [Pg.105]

Therefore, if the excited-state lifetimes r0 and Tq are known, the plot of ( / 0)/( / ) versus [H30+] yields the rate constants k3 and k i. However, it should be emphasized that corrections have to be made (i) the proton concentration must be replaced by the proton activity (ii) the rate constant k 3 must be multiplied by a correction factor involving the ionic strength (if the reaction takes place between charged particles), because of the screening effect of the ionic atmosphere on the charged reactive species. [Pg.105]


Nonradiative reiaxation and quenching processes wiii aiso affect the quantum yieid of fluorescence, ( )p = /cj /(/cj + Rsiative measurements of fluorescence quantum yieid at different quencher concentrations are easiiy made in steady state measurements absoiute measurements (to detemrine /cpjj ) are most easiiy obtained by comparisons of steady state fluorescence intensity with a fluorescence standard. The usefuiness of this situation for transient studies... [Pg.2959]

Elasticity is another manifestation of non-Newtonian behavior. Elastic Hquids resist stress and deform reversibly provided that the strain is not too large. The elastic modulus is the ratio of the stress to the strain. Elasticity can be characterized usiag transient measurements such as recoil when a spinning bob stops rotating, or by steady-state measurements such as normal stress ia rotating plates. [Pg.304]

Then the molecular volume may be determined as for steady state measurements using Equation 6. [Pg.190]

Unsteady reaction data are often an excellent means for estimating physical parameters that would be difficult or impossible to elucidate from steady-state measurements. However, the associated problems in nonlinear optimization can be formidable. A recent review and comparison of methods is given by... [Pg.538]

LOAD, LOADl, LOAD2 = terms in the process model to accommodate non-zero steady state measurements (present values) at zero controller output, i.e. if the heaters are off (0 power) the temperature will not be 0. Also can be changed to represent undesired disturbances to the system affecting control. [Pg.502]

Rate constants governing re-orientation of the glucose transporter, and their activation energies, determined from steady-state and pre-steady-state measurements... [Pg.181]

Steady state measurements of NO decomposition in the absence of CO under potentiostatic conditions gave the expected result, namely rapid self-poisoning of the system by chemisorbed oxygen addition of CO resulted immediately in a finite reaction rate which varied reversibly and reproducibly with changes in catalyst potential (Vwr) and reactant partial pressures. Figure 1 shows steady state (potentiostatic) rate data for CO2, N2 and N2O production as a function of Vwr at 621 K for a constant inlet pressures (P no, P co) of NO and CO of 0.75 k Pa. Also shown is the Vwr dependence of N2 selectivity where the latter quantity is defined as... [Pg.515]

Steady-state measurements of polarization characteristics can be made when all transitory processes associated with changes in current or potential have ended. Here... [Pg.195]

In steady-state measurements at current densities such as to cause surface-concentration changes, the measuring time should be longer than the time needed to set up steady concentration gradients. Microelectrodes or cells with strong convection of the electrolyte are used to accelerate these processes. In 1937, B. V. Ershler used for this purpose a thin-layer electrode, a smooth platinum electrode in a narrow cell, contacting a thin electrolyte layer. [Pg.196]

Steady-state measurements can be made pointwise or continuously. In the first case the level of perturbation (current or potential) is varied discontinuously, and at some time after the end of transitory processes the response is measured. In the second case the perturbation level is varied continuously, but slowly so as not to disturb the system s steady state. [Pg.196]

It is basically irrelevant in steady-state measurements in which direction the polarization curves are recorded that is, whether the potential is moved in the direction of more positive (anodic scan) or more negative (cathodic scan) values. But sometimes the shape of the curves is seen to depend on scan direction that is, the curve recorded in the anodic direction does not coincide with that recorded in the cathodic direction (Eig. 12.3). This is due to changes occurring during the measurements in the properties of the electrode surface (e.g., surface oxidation at anodic potentials) and producing changes in the kinetic parameters. [Pg.196]

Steady-state measurements can be made under both galvanostatic and potentiostatic conditions. It is irrelevant for the results of the measurements whether the current or the potential was set first. But in certain cases in which the polarization (/ vs. E) curve is nonmonotonic and includes a falling section (BC in Fig. 12.4), the potentiostatic method has important advantages, since it allows the potential to be set to any point along the curve and the corresponding current measured. But when the galvanostatic method is used, an increase in current beyond point B causes a jump in potential to point D (i.e., the potential changes discontinuously from the value Eg to the value Eg,) and the entire intermediate part of the curve is inaccessible. [Pg.197]

The concentration of the transferred ion in organic solution inside the pore can become much higher than its concentration in the bulk aqueous phase [15]. (This is likely to happen if r <5c d.) In this case, the transferred ion may react with an oppositely charged ion from the supporting electrolyte to form a precipitate that can plug the microhole. This may be one of the reasons why steady-state measurements at the microhole-supported ITIES are typically not very accurate and reproducible [16]. Another problem with microhole voltammetry is that the exact location of the interface within the hole is unknown. The uncertainty of and 4, values affects the reliability of the evaluation of the formal transfer potential from Eq. (5). The latter value is essential for the quantitative analysis of IT kinetics [17]. Because of the above problems no quantitative kinetic measurements employing microhole ITIES have been reported to date and the theory for kinetically controlled CT reactions has yet to be developed. [Pg.383]

Alternatively, a higher rate of mass transport in steady-state measurements with a larger UME can be obtained by using it as a tip in the scanning electrochemical microscope (SECM). The SECM has typically been employed for probing interfacial ET reactions [29]. Recently, micropipettes have been used as SECM probes (see Section IV.B below) [8b,30]. Although the possibility of probing simple and assisted IT at ITIES by this technique was demonstrated, no actual kinetic measurements have yet been reported. [Pg.392]

At time t=212 h the continuous feeding was initiated at 5 L/d corresponding to a dilution rate of 0.45 d . Soon after continuous feeding started, a sharp increase in the viability was observed as a result of physically removing dead cells that had accumulated in the bioreactor. The viable cell density also increased as a result of the initiation of direct feeding. At time t 550 h a steady state appeared to have been reached as judged by the stability of the viable cell density and viability for a period of at least 4 days. Linardos et al. (1992) used the steady state measurements to analyze the dialyzed chemostat. Our objective here is to use the techniques developed in Chapter 7 to determine the specific monoclonal antibody production rate in the period 212 to 570 h where an oscillatory behavior of the MAb titer is observed and examine whether it differs from the value computed during the start-up phase. [Pg.333]

Equations (2.10) and (2.12) are identical except for the substitution of the equilibrium dissociation constant Ks in Equation (2.10) by the kinetic constant Ku in Equation (2.12). This substitution is necessary because in the steady state treatment, rapid equilibrium assumptions no longer holds. A detailed description of the meaning of Ku, in terms of specific rate constants can be found in the texts by Copeland (2000) and Fersht (1999) and elsewhere. For our purposes it suffices to say that while Ku is not a true equilibrium constant, it can nevertheless be viewed as a measure of the relative affinity of the ES encounter complex under steady state conditions. Thus in all of the equations presented in this chapter we must substitute Ku for Ks when dealing with steady state measurements of enzyme reactions. [Pg.37]

Transient kinetic experiments have also been carried out to complement the information deduced from the steady-state measurements [33], Systematic variations were observed during the transition from the clean surface to the steady-state catalytic regime that correlate well with the overall reaction rates in the latter. Specifically, there is a time delay in the production of molecular nitrogen because of the need to buildup a threshold of atomic nitrogen coverage on the surface. This atomic nitrogen coverage, which could... [Pg.73]

In the present case, the electron hopping chemistry in the polymeric porphyrins is an especially rich topic because we can manipulate the axial coordination of the porphyrin, to learn how electron self exchange rates respond to axial coordination, and because we can compare the self exchange rates of the different redox couples of a given metallotetraphenylporphyrin polymer. To measure these chemical effects, and avoid potentially competing kinetic phenomena associated with mobilities of the electroneutrality-required counterions in the polymers, we chose a steady state measurement technique based on the sandwich electrode microstructure (19). [Pg.414]

Every time an excited molecule exits the excited state region by the fluorescence pathway it emits a photon. We can either count the number of photons in a longer time interval (by a steady-state measurement of the fluorescence intensity) or make a time-resolved measurement of the fluorescence decay. These measurements can be done in an ensemble mode or on single molecules—the basic process is the same. The number of photons collected from the donor emission will be depicted by IDA and ID, where we mean the fluorescence intensity of D in the presence (Ida) and absence (ID) of acceptor. All other conditions, other than the presence or absence of acceptor, remain the same. During the same time of the experiment where we have measured the photons emitted by D, many of the excited D molecules have exited from the excited state by a pathway other than fluorescence. Obviously, the number of times a pathway has been chosen as an exit pathway is proportional to the... [Pg.48]

The UMEs used in bioarrays can be divided into three types disk, ring, and strip electrodes. The theory of the disk, ring, and strip UMEs has been extensively studied [97-100], Due to the edge effect, the profile of the mass diffusion to the ultramicroelectrode surface is three dimensional, and can significantly enhance the mass transportation in comparison to the conventional large electrode with one-dimensional mass transportation. The steady-state measurement at a planar UME can be expressed as... [Pg.371]

The method of isotopic transient reaction kinetics (see 5), applied in a chemical steady state is an elegant application of the true steady state measurement. [Pg.265]

Kinetic investigations of catalytic processes under transient conditions have to take into account this problem (see e.g. (4 ), where the macrorelaxation of the redox type reaction has been suppressed by means of a specific periodic operation). Kinetic expressions obtained by dynamic methods in general would give a better understanding of the rate law than those obtained from steady state measurements. [Pg.278]

Under continuous illumination, the concentration [1A ] remains constant, which means that JA is in a steady state. Measurements under these conditions are then called steady-state measurements. [Pg.49]

The difference between the theoretical value of the emission anisotropy in the absence of motions (fundamental anisotropy) and the experimental value (limiting anisotropy) deserves particular attention. The limiting anisotropy can be determined either by steady-state measurements in a rigid medium (in order to avoid the effects of Brownian motion), or time-resolved measurements by taking the value of the emission anisotropy at time zero, because the instantaneous anisotropy can be written in the following form ... [Pg.137]

This section deals with a single donor-acceptor distance. Let us consider first the case where the donor and acceptor can freely rotate at a rate higher than the energy transfer rate, so that the orientation factor k2 can be taken as 2/3 (isotropic dynamic average). The donor-acceptor distance can then be determined by steady-state measurements via the value of the transfer efficiency (Eq. 9.3) ... [Pg.250]


See other pages where Steady State Measurements is mentioned: [Pg.88]    [Pg.342]    [Pg.226]    [Pg.361]    [Pg.180]    [Pg.181]    [Pg.196]    [Pg.493]    [Pg.314]    [Pg.253]    [Pg.259]    [Pg.264]    [Pg.169]    [Pg.169]    [Pg.128]    [Pg.49]    [Pg.414]    [Pg.370]    [Pg.260]    [Pg.124]    [Pg.139]    [Pg.151]    [Pg.567]    [Pg.105]   
See also in sourсe #XX -- [ Pg.248 , Pg.423 , Pg.424 , Pg.425 , Pg.426 , Pg.427 ]




SEARCH



Charge transport steady-state measurements

Conductivity measurements steady-state electronic current

Kinetic measurement steady-state flow experiments

Measurement of steady-state H2S levels in blood and tissue

State measurement

Steady Measurements

Steady-State Polarization Measurements

Steady-State Shear Flow Measurement

Steady-state NOE measuring

Steady-state current measurements

Steady-state electrical measurement

Steady-state electrical measurement conductivity

Steady-state fluorescence measurement

Steady-state kinetics measurement methods

Steady-state photocurrent measurement

Steady-state polarization anisotropy measurements

The study of kinetics by steady-state measurements

© 2024 chempedia.info