Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Measurements transient

As formalised in the BSP, the viseoelastic response of a sample of polymer depends on the mechanical history of the sample up to the time when the response is measured. It is therefore necessary to condition the sample before making measurements by subjecting it to successive creep and recovery cycles in the following way  [Pg.198]

The simplest method for measuring exlensional creep is the dead-loading method. The simplest form of this uses a cathetometer to measure, at various times, the separation of two marks on a long sample hanging under a fixed load. A cathetometer is simply a device consisting of a vertical stand along which a horizontally mounted microscope (or telescope) can be moved. A more sophisticated version of this experiment [Pg.198]


The direct analysis of short-lived radioactive isotopes using the method outlined in Example 13.6 is less useful since it provides only a transient measure of the isotope s concentration. The concentration of the isotope at a particular moment... [Pg.644]

Elasticity is another manifestation of non-Newtonian behavior. Elastic Hquids resist stress and deform reversibly provided that the strain is not too large. The elastic modulus is the ratio of the stress to the strain. Elasticity can be characterized usiag transient measurements such as recoil when a spinning bob stops rotating, or by steady-state measurements such as normal stress ia rotating plates. [Pg.304]

Our results also shed light on the long-lived PA3 band detected in transient PM measurements of P3BT (see Fig. 7-19) and can explain changes in the PA spectra observed in several ps transient measurements of films of PPV derivatives at energies around 1.8 eV [9, 25, 60J. In good PPV films the transient PA spectrum shows a PA band of excitons at 1.5 eV whose dynamics match those of the PL and stimulated emission (SE) [9J. However, in measurements of oxidized [25] or C60-doped films 60, there appears a new PA band at about 1.8 eV whose dynamics are not correlated with those of the PL and SE. Based on our A-PADMR results here, we attribute the new PA band at 1.8 eV to polaron pair excitations. These may be created via exciton dissociation at extrinsic defects such as carbo-... [Pg.128]

Otherwise, the effect of electrode potential and kinetic parameters as contained in the relevant expression for the PMC signal (21), which controls the lifetime of PMC transients (40), may lead to an erroneous interpretation of kinetic mechanisms. The fact that lifetime measurements of PMC transients largely match the pattern of PMC-potential curves, showing peaks in accumulation and depletion of the semiconductor electrode and a minimum at the flatband potential [Figs. 13, 16-18, 34, and 36(b)], demonstrates that kinetic constants are accessible via PMC transient measurements, as indicated by the simplified relation (40) derived for the depletion layer of an n-type electrode. [Pg.504]

How can such problems be counterbalanced Since a large capacitance of a semiconductor/electrolyte junction will not negatively affect the PMC transient measurement, a large area electrode (nanostructured materials) should be selected to decrease the effective excess charge carrier concentration (excess carriers per surface area) in the interface. PMC transient measurements have been performed at a sensitized nanostructured Ti02 liquidjunction solar cell.40 With a 10-ns laser pulse excitation, only the slow decay processes can be studied. The very fast rise time cannot be resolved, but this should be the aim of picosecond studies. Such experiments are being prepared in our laboratory, but using nanostructured... [Pg.505]

Figure 38. Decay of PMC transients measured with a TSO -based nanostructured sensitization solar cell (ruthenium complex as sensitizer in the presence of 0.1 M TBAP in propylene carbonate). The transients are significantly affected by additions of iodide.40 (a) no I", (b) 2 mM r, (c) 20 mM r. (d) 200 mMT. Figure 38. Decay of PMC transients measured with a TSO -based nanostructured sensitization solar cell (ruthenium complex as sensitizer in the presence of 0.1 M TBAP in propylene carbonate). The transients are significantly affected by additions of iodide.40 (a) no I", (b) 2 mM r, (c) 20 mM r. (d) 200 mMT.
On the basis of our theoretical considerations and preliminary experimental work, it is hoped that fast processes of charge carriers will become directly measurable in functioning photoelectrochemical cells, Typical semiconductor electrodes are not the only systems accessible to potential-dependent microwave transient measurements. This technique may also be applied to the interfacial processes of semimetals (metals with energy gaps) or thin oxide or sulfide layers on ordinary metal electrodes. [Pg.506]

In electrochemical systems, transient processes are of major practical significance because they are an efficient route for studying electrode reactions and phenomena (see Chapter 12). In addition, transient measurements are useful for analytical purposes (see Chapter 23). [Pg.181]

It is the essence of transient measurements that a certain perturbation is applied to the electrode and then the response is recorded as a function of time. Usually, the transition times are short (fractions of a second), and the transient measurements are performed very rapidly with automated data acquisition. [Pg.199]

FIGURE 12.6 Various types of perturbation for transient measurements. [Pg.200]

For the individual types of transient measuring techniques, special names exist but their terminology lacks uniformity. The potentiostatic techniques where the time-dependent current variation is determined are often called chronoamperometric, and the galvanostatic techniques where the potential variation is determined are called chronopotentiometric. For the potentiodynamic method involving linear potential scans, the term voltammetry is used, but this term is often used for other transient methods as well. [Pg.200]

In transient measurements one must record rapidfy changing currents or potentials. In the past, cathode-ray oscilloscopes have been used for this purpose (at present, improved recording devices or computers are used as well), hence the term oscillographic polarography (or oscillographic voltammetry). This term is unfortunate since it reflects only the device used to record the results, rather than the essential features of the method used for the measurements. [Pg.395]

The control experiment in pure supporting electrolyte (dotted lines in Fig. 13.2) shows a sharp faradaic current spike, which is mainly due to pseudocapacitive contributions (adsorption of (bi)sulfate and rearrangement of the double layer) plus oxidation of adsorbed Hupd (dotted lines in Fig. 13.2a), but no measurable increase in the CO2 partial pressure (m/z = 44 current) above the background level (dotted lines in Fig. 13.2b). Therefore, a measurable adsorption of trace impurities from the base electrolyte can be ruled out on the time scale of our experiments. Moreover, this experiment also demonstrates the advantage of mass spectrometric transient measurements compared with faradaic current measurements, since the initial reaction signal is not obscured by pseudocapacitive effects and the related faradaic current spike. [Pg.421]

The models incorporate two microscopic parameters, the site density and the critical nucleus size. A fit of experimental current transients to the models allows conclusions, for example, concerning the effect of additives on nucleation rate. Fabricus et al. found by analysis of current transients that thiourea increases the nucleation density of copper deposited on glassy carbon at low concentration, but decreases it at higher concentration [112], Schmidt et al. found that Gold nucleation on pyrolytic graphite is limited by the availability of nucleation sites [113], Nucleation density and rate were found to depend on applied potential as was the critical nucleus size. Depending on concentration, critical nuclei as small as one atom have been estimated from current transient measurements. Michailova et al. found a critical nucleus of 11 atoms for copper nucleation on platinum [114], These numbers are typical, and they are comparable to the thermodynamic critical radii [86],... [Pg.178]

Figure 10. Kleitz s reaction pathway model for solid-state gas-diffusion electrodes. Traditionally, losses in reversible work at an electrochemical interface can be described as a series of contiguous drops in electrical state along a current pathway, for example. A—E—B. However, if charge transfer at point E is limited by the availability of a neutral electroactive intermediate (in this case ad (b) sorbed oxygen at the interface), a thermodynamic (Nernstian) step in electrical state [d/j) develops, related to the displacement in concentration of that intermediate from equilibrium. In this way it is possible for irreversibilities along a current-independent pathway (in this case formation and transport of electroactive oxygen) to manifest themselves as electrical resistance. This type of chemical valve , as Kleitz calls it, may also involve a significant reservoir of intermediates that appears as a capacitance in transient measurements such as impedance. Portions of this image are adapted from ref 46. (Adapted with permission from ref 46. Copyright 1993 Rise National Laboratory, Denmark.)... Figure 10. Kleitz s reaction pathway model for solid-state gas-diffusion electrodes. Traditionally, losses in reversible work at an electrochemical interface can be described as a series of contiguous drops in electrical state along a current pathway, for example. A—E—B. However, if charge transfer at point E is limited by the availability of a neutral electroactive intermediate (in this case ad (b) sorbed oxygen at the interface), a thermodynamic (Nernstian) step in electrical state [d/j) develops, related to the displacement in concentration of that intermediate from equilibrium. In this way it is possible for irreversibilities along a current-independent pathway (in this case formation and transport of electroactive oxygen) to manifest themselves as electrical resistance. This type of chemical valve , as Kleitz calls it, may also involve a significant reservoir of intermediates that appears as a capacitance in transient measurements such as impedance. Portions of this image are adapted from ref 46. (Adapted with permission from ref 46. Copyright 1993 Rise National Laboratory, Denmark.)...
One general method may always be used to reduce the effect of impurity adsorption on electrodes, and that is to work only for shorl times. Impurities take substantial times to adsorb. If the time in which the measurement is made is short enough, the adsorption aspect of impurity interference with electrode kinetic measurements can be reduced. Many of the techniques for doing this are described in Chapter 8 (transients). However, this approach does not eliminate the difficulty that at low current densities impurities in the solution may compete with electrons from the electrode. Further, although transient measurements may greatly reduce the adsorption of impurities during the measurement, it is difficult to arrange techniques so that the electrode is in contact with the solution for seconds only. [Pg.376]

These early transient measurements were then developed with a rather different motive than that described above. Now (cf. Esq. 7.)... [Pg.686]


See other pages where Measurements transient is mentioned: [Pg.2959]    [Pg.151]    [Pg.154]    [Pg.255]    [Pg.493]    [Pg.496]    [Pg.499]    [Pg.501]    [Pg.501]    [Pg.504]    [Pg.514]    [Pg.231]    [Pg.421]    [Pg.423]    [Pg.330]    [Pg.200]    [Pg.371]    [Pg.126]    [Pg.349]    [Pg.44]    [Pg.260]    [Pg.6]    [Pg.2]    [Pg.508]    [Pg.563]    [Pg.189]    [Pg.187]    [Pg.383]    [Pg.41]    [Pg.686]   
See also in sourсe #XX -- [ Pg.33 , Pg.34 ]




SEARCH



A Transient measurements

Bulk Transient Measurements

Calcium transient measurements

Charge transport transient photocurrent measurements

Deep level measurements transient method

Electrode fast transients, measurement

Femtosecond transient absorption measurements

Grounding transient responses measurement

Kinetic measurement transient flow experiments

Measured transient response

Measurement Techniques for Optical Transients

Measurement transient rapid response

Measurements of Fast Transient Events

Nuclear magnetic resonance transient measurement

Optical transient measurement

Picosecond Transient Absorption Measurements

Poly photocurrent transient measurements

Potentiostatic current transient measurements

Temperature measurement transient

The Need to Measure Fast Transients

Transient (Pulse) Measurements

Transient Photocurrent Measurements

Transient Photoinduced Discharge Measurements

Transient SSITKA measurements

Transient absorption measurements

Transient absorption measurements apparatus

Transient absorption measurements spectrum generation

Transient absorption measurements spectrum generation time-resolved spectra

Transient absorption spectroscopy pump-probe measurement

Transient absorption spectroscopy slow measurement

Transient current measurements

Transient current measurements poly

Transient electrical measurements

Transient measurements, insulating

Transient program measured results

Transient program measuring results

Transient transport measurements

Transient transport measurements model

© 2024 chempedia.info