Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Standard determination

A multiple-point standardization presents a more difficult problem. Consider the data in Table 5.1 for a multiple-point external standardization. What is the best estimate of the relationship between Smeas and Cs It is tempting to treat this data as five separate single-point standardizations, determining k for each standard and reporting the mean value. Despite its simplicity, this is not an appropriate way to treat a multiple-point standardization. [Pg.117]

Assume that p-xylene is the analyte and that methylisobutylketone is the internal standard. Determine the 95% confidence interval for a single-point standardization, with and without using the internal standard. [Pg.574]

The concentration of Ni in a new alloy is determined by a neutron activation analysis using the method of external standards. A 0.500-g sample of the alloy and a 1.000-g sample of a standard alloy known to contain 5.93% w/w Ni are irradiated with neutrons in a nuclear reactor. When irradiation is complete, the sample and standard are allowed to cool, and the gamma-ray activities are measured. Given that the activity is 1020 cpm for the sample and 3540 cpm for the standard, determine the %w/w Ni in the alloy. [Pg.663]

The movement toward federal appliance efficiency standards stalled in the 1980s as the Reagan Administration, which opposed standards from an ideological perspective, began. That administration s approach was made evident by its refusal to finalize the DOE s 1980 standards proposal, and in 1983, by the issuance of a federal rule that determined that no standards were necessary. Both the delay and the no standard determination were challenged by NRDC, with the support of several large states, through the courts. [Pg.79]

NMR with the C3 proton used as an internal standard. Determination of hydrogen content at C4 was not possible on the 200 MHz instrument due to overlapping peaks. [Pg.253]

Plot the absorbance versus cysteine concentration for each of the standards. Determine the sulfhydryl concentration of the samples by comparison to the standard curve. [Pg.101]

Speciation of a solution of mixed arsenic standards determine the limit of detection observe and explain the effects of pre-reduction. [Pg.173]

Fig. 4.5.1. Hardness curve of Mohs standard determined on means from five measurements made by scratch and abrasion methods, and from five measurements by indentation method compared with the parabolic curve y = x3. (After Povarennykh, 1963)... Fig. 4.5.1. Hardness curve of Mohs standard determined on means from five measurements made by scratch and abrasion methods, and from five measurements by indentation method compared with the parabolic curve y = x3. (After Povarennykh, 1963)...
Somers, T.C. and Ziemelis, G. 1980. Gross interference by sulphur dioxide in standard determinations of wine phenolics. J. Sci. Food Agric. 31 600-610. [Pg.1238]

Safe levels for standards determined by reentry studies d/ Spear et al. (7) e/ estimated, f/ Richards et al. (8). [Pg.26]

Prepare a calibration curve by plotting turbidity (in NTU if a nephelometer is used) or absorbance or transmittance (if a spectrophotometer or filter photometer is used) of BaS04 formed against the corresponding concentrations of S042 standards. Determine the concentration of S042 in the sample from the standard calibration curve. [Pg.249]

Abstract Internal standards play critical roles in ensuring the accuracy of reported concentrations in LC-MS bioanalysis. How do you find an appropriate internal standard so that analyte losses and experimental variations during sample preparation, chromatographic separation, and mass spectrometric detection could be corrected How is the concentration of an internal standard determined Should internal standard responses be monitored during the analysis of incurred samples What are the main causes for internal standard response variations How do they impact the quantitation Why are stable isotope labeled internal standards preferred And yet one should still have an open-mind in their usage for the analysis of incurred samples. All these questions are addressed in this chapter supported by theoretical considerations and practical examples. [Pg.1]

In other words, the purity of analyte and IS reference standards determines the maximum possible concentration span. Sometimes, it is impossible to simultaneously satisfy both (1) and (2), i.e C >C In this case, either calibration range needs to be adjusted (narrowed) or analyte or internal standard reference standards of higher purity must be used. [Pg.7]

Whereas the radioactivity measurement alone does not allow distinguishing between drug and metabo-lite(s), samples obtained from the described studies should be also used for standard determination of the drug and its known metabolites, receiving information about the drag and the known metabolite kinetics directly. The gap between radioactivity concentrations and the concentrations determined by direct bioana-lytical methods defines the contribution of unknown metabolites. [Pg.559]

Nitric Oxide The ro-vibrational line selected for NO measurements is in the 1900 cm 1 region. Bottled gas of NO in Ne at a concentration of a few ppmv traceable to a National Bureau of Standards determination has been used as the calibration source for NO. The response time of the system for this gas is the residence time in the cell of 3 sec. The minimum detection limit MDC defined as a signal to noise of unity is better than 40 pptv (parts per 10ls by volume) for an integration time of 5 min fhe... [Pg.277]

The pressure generated in the chamber of a weapon its value depends to a large extent on the nature of the weapon and of the powder selected. Standard determinations of gas pressure are carried out with the aid of a crusher ( measuring egg ) - a copper cylinder or a copper... [Pg.204]

Judgment Determines if documentation meets standards. Determines how best to resolve the situation. [Pg.93]

Note that 8 values are practical, dimensionless parameters. Since values of 8 in namre are small, they are generally given in %c (per mil)— which is a 1Q3 factor, not a unit. Further, only the arbitrary choice of standard determines whether a 8 value of a sample is positive or negative (Mook, 2000). [Pg.2089]

Table I shows the MWs and the RMS radii of the PS standard determined with different dn/dc and A2 values. Equations 11 and 13 indicate that both the MW and the RMS radius increase as A2 increases. No significant changes were observed in MWs and sizes when A2 was varied at the constant dn/dc value of 0.2. It is noted that A2 could be assumed to be zero. As mentioned earlier, the product A cM is usually... Table I shows the MWs and the RMS radii of the PS standard determined with different dn/dc and A2 values. Equations 11 and 13 indicate that both the MW and the RMS radius increase as A2 increases. No significant changes were observed in MWs and sizes when A2 was varied at the constant dn/dc value of 0.2. It is noted that A2 could be assumed to be zero. As mentioned earlier, the product A cM is usually...
Table I. Molecular Weights and RMS Radii of 250,000 MW PS Standard Determined by ThFFF-MALLS-RI Using Different dn/dc and A2 Values... Table I. Molecular Weights and RMS Radii of 250,000 MW PS Standard Determined by ThFFF-MALLS-RI Using Different dn/dc and A2 Values...
Sieves sieving and other sizing methods. In Draft of Standard Determination of Particle Size Distribution, Laser Diffraction Methods International Organization for Standardization (ISO) Berlin, Germany. [Pg.2594]

In addition to the Pharmacopeia of Japan, there are several compendia, standards, and guides in which Japanese standards for pharmaceuticals are published. The following are standards determined for drugs under the provisions noted above, although the specifications and standards included in these compendia are mandatory. As presented above, some of the monographs in the following compendia are quoted in the JP ... [Pg.2838]

Nearly equal numbers of industrial and academic scientists are involved with USP and NF standards determinations, and 10 of 20 DSD Executive Committee members are industrial. An average of half of the DSD Executive Committee consisted of industrial scientists during the last three cycles. The DSD Executive Committee is the policy-setting body and addresses all broad-interest topics. Pharmaceutical technology is the predominant category of information discussed. Other participants include government scientists and medical and pharmacy practitioners. [Pg.2853]

Standardization Determination of the concentration of a solution by calibration, directly or indirectly, with a primary standard. [Pg.1118]

The ISO 14040 standard determines four basic stages for LCA studies, schematically represented in Figure 5.9. Goal and scope definition is the first stage of the study and one of the most important, since the elements defined here, such as... [Pg.310]

The method described above forms the basis of the standard determination of the one-dimensional consolidation properties of soils for civil engineering purposes16. The diameter of the cell is not specified other than it should be at least 6 mm smaller than the soil samples available for testing, and the depth of the ring is... [Pg.94]

ISO (1999) Draft international Standard Determination of platinum in platinum jewelry alloys -Method using inductively coupled plasma emission spectrometry on a solution with yttrium as internal standard ISO/DIS 11494.2 ISO/TC 174. [Pg.1079]


See other pages where Standard determination is mentioned: [Pg.222]    [Pg.335]    [Pg.262]    [Pg.208]    [Pg.335]    [Pg.599]    [Pg.369]    [Pg.25]    [Pg.54]    [Pg.11]    [Pg.82]    [Pg.953]    [Pg.15]    [Pg.380]    [Pg.81]    [Pg.265]    [Pg.184]    [Pg.141]    [Pg.146]    [Pg.73]    [Pg.549]    [Pg.312]   
See also in sourсe #XX -- [ Pg.10 ]

See also in sourсe #XX -- [ Pg.10 ]




SEARCH



Accuracy, activity determination standard addition method

Concentration Determination through Standard Solution Addition

Determination of lead with standard potassium dichromate solution

Determination of standard uncertainties for protein-ligand contacts

Determination of sulphate with standard lead nitrate solution

Determination standard form

Reference Standards for the Determination of Fluorescence Quantum Yields

Reference Standards for the Determination of Phosphorescence Quantum Yields

Reference standard material concentration determination

Some Comments about the Standard Plot of Determining Mesoporosity

Standard Deviations Obtained from Several Independent Determinations

Standard Practice for Plastics Dynamic Mechanical Properties Determination and Report of Procedures

Standard Test Method for Determination of Phenolic Antioxidants and Erucamide Slip Additives in Linear Low-Density Polyethylene Using Liquid Chromatography

Standard Test Method for Determination of Phenolic Antioxidants and Erucamide Slip Additives in Low-Density Polyethylene Using Liquid Chromatography

Standard Test Method for Determination of Phenolic Antioxidants and Erucamide Slip Additives in Polypropylene Homopolymer Formulations Using Liquid Chromatography

Standard Test Method for Determining Ignition Temperature of Plastics

Standard cell potential experimental determination

Standard deviation, determination

Standard electrode potential determination

Standard half-cell potentials determination

Standard potential determination

Standard rate constant determination

Standard reduction potentials determination

Standard-state potential, determining

Standard-state potential, determining voltammetry

Stepwise reaction, determining standard

The Standardized Determination of Hemoglobin

Using Standard Molecular Orbital Software to Compute Single Valence Bond Structures or Determinants

© 2024 chempedia.info