Multiple point

B.2 Single-Point versus Multiple-Point Standardizations ... [Pg.108]

A fifth spectrophotometric method for the quantitative determination of the concentration of Pb + in blood uses a multiple-point standard addition based on equation 5.6. The original blood sample has a volume of 1.00 mb, and the standard used for spiking the sample has a concentration of 1560 ppb Pb +. All samples were diluted to 5.00 mb before measuring the signal. A calibration curve of Sjpike versus Vj is described by... [Pg.114]

A multiple-point standardization presents a more difficult problem. Consider the data in Table 5.1 for a multiple-point external standardization. What is the best estimate of the relationship between Smeas and Cs It is tempting to treat this data as five separate single-point standardizations, determining k for each standard and reporting the mean value. Despite its simplicity, this is not an appropriate way to treat a multiple-point standardization. [Pg.117]

Data for Hypothetical Multiple-Point External Standardization... [Pg.117]

How do we find the best estimate for the relationship between the measured signal and the concentration of analyte in a multiple-point standardization Figure 5.8 shows the data in Table 5.1 plotted as a normal calibration curve. Although the data appear to fall along a straight line, the actual calibration curve is not intuitively obvious. The process of mathematically determining the best equation for the calibration curve is called regression. [Pg.118]

Standardizations using a single standard are common, but also are subject to greater uncertainty. Whenever possible, a multiple-point standardization is preferred. The results of a multiple-point standardization are graphed as a calibration curve. A linear regression analysis can provide an equation for the standardization. [Pg.130]

Creep, creep mpture, and stress relaxation tests are multiple-point tests requiring long periods of time (1000 h min) to generate useflil data these are standard tests for determining more fundamental polymer properties (202,203). Data for these tests are generated under several... [Pg.153]

Seals should be non-contacting, multiple point labyrinths. The housing and seals should be drilled and the housing tapped to accommodate a dr ... [Pg.332]

A variation on depth profiling that can be performed by modern scanning Auger instruments (see Sect. 2.2.6) is to program the incident electron beam to jump from one pre-selected position on a surface to each of many others in turn, with multiplexing at each position. This is called multiple point analysis. Sets of elemental maps acquired after each sputtering step or each period of continuous sputtering can be related to each other in a computer frame-store system to derive a three-dimensional analysis of a selected micro volume. [Pg.42]

Pierce, T.E. and D.B. Turner, 1980. User s Guide for MPTER - A Multiple Point Gaussian Dispersion Algorithm With Optional Terrain Adjustment. EPA-600/8-80-016. U.S. Environmental Protection Agency, Research Triangle Park, NC. [Pg.344]

COMPLEX I is a multiple point-source code with terrain adjustment representing a sequential modeling bridge between VALLEY and COMPLEX II. [Pg.384]

MPTER is a multiple point-source Gaussian model witli optional terrain adjustments. [Pg.384]

MESOPUFF is a Lagrangian model suitable for modeling die transport, diffusion and removal of air pollutants from multiple point and area sources at transport distances beyond 10-50 KM. [Pg.385]

Note Multiple points indicate separate observations or different assumptions of heat content. [Pg.530]

The size of the EDTA ring structure complex (not too big or too small), plus the multiple points of attachment, provides a very stable complex (high stability constant) that overcomes reaction tendencies to reach equilibrium via the lowest possible energy state or maximum state of disorder (entropy). [Pg.431]

Internal sultones, formed from internal alkenes, may also occur. These react less readily than corresponding terminal sultones. In addition, feedstock materials contain alkenes with multiple points of unsaturation, which may form unsaturated sultones such as the unsaturated y-sultone upon sulfonation. [Pg.444]

Figure 3. Detection of thermal source through multiple point heterodyne... Figure 3. Detection of thermal source through multiple point heterodyne...
Alba, R. et al., Transcriptome and selected metabolite analyses reveal multiple points of ethylene control during tomato fruit development, Plant Cell 17, 2954, 2005. [Pg.397]

BCR Analytical Approach for the Certification of PAHs in Natural Matrix CRMs Prior to the certification analyses for the CRM, each participating laboratory has to prepare standard solutions of the analytes to be determined from certified reference compounds (purity >99.0 %) to calibrate their instruments for response and response linearity (multiple point calibration), detection limit, and reproducibility. In the case of PAH measurements, reference compounds of certified purity are used as internal standards, which are not present at a detectable concentration in the matrix to be analyzed (e.g. indeno[i,2,3-cd]fluoranthene (CRM 267), 5-methylchrysene (CRM 081R), benzo[f ]chry-sene (CRM 046), picene (CRM 168), and/or phenanthrene-dio). [Pg.99]

The horizontal part is due to the uncatalyzed rate constant, k+, in Eq. (43). A pH profile can be done at, for example, six pH values, and since there are two kinetic points (times) and two buffer concentrations at each, a total of 24 assays are needed, which is not insurmountable. This number may be minimized and optimized by careful selection of pH and buffer concentrations [60]. Later in the program the pH profile should be repeated but with multiple points and several buffer concentrations, but this is beyond the point of preformulation. An example of a full pH profile is one running from pH 1 to pH 11 [61-64]. [Pg.188]

Qian Y-W, Erikson E, Mailer JL 1998a Purification and cloning of a protein kinase that phosphorylates and activates the polo-like kinase Plxl. Science 282 1701-1704 Qian Y-W, Li C, Erikson E, Mailer JL 1998b Activated polo-like kinase Plxl is required at multiple points during mitosis in Xenopus laevis. Mol Cell Biol 18 4262-4271 Richter JD 1999 Cytoplasmic polyadenylation in development and beyond. Microbiol Mol Biol Rev 63 446-456... [Pg.72]

Input Errors. Errors in model input often constitute one of the most significant causes of discrepancies between observed data and model predictions. As shown in Figure 2, the natural system receives the "true" input (usually as a "driving function") whereas the model receives the "observed" input as detected by some measurement method or device. Whenever a measurement is made possible source of error is introduced. System inputs usually vary continuously both in space and time, whereas measurements are usually point values, or averages of multiple point values, and for a particular time or accumulated over a time period. Although continuous measurement devices are in common use, errors are still possible, and essentially all models require transformation of a continuous record into discrete time and space scales acceptable to the model formulation and structure. [Pg.157]


See other pages where Multiple point is mentioned: [Pg.61]    [Pg.109]    [Pg.109]    [Pg.109]    [Pg.113]    [Pg.130]    [Pg.775]    [Pg.811]    [Pg.98]    [Pg.204]    [Pg.523]    [Pg.194]    [Pg.393]    [Pg.274]    [Pg.264]    [Pg.407]    [Pg.273]    [Pg.359]    [Pg.339]    [Pg.129]    [Pg.10]    [Pg.364]   
See also in sourсe #XX -- [ Pg.214 ]

See also in sourсe #XX -- [ Pg.169 ]




SEARCH



Boiling points multiple

Crossover multiple/single-point

External standardization multiple-point

Melting point multiple

Multiple consolidation and break points

Multiple inflection points

Multiple oxides point defects

Multiple point calibration

Multiple point calibration linear

Multiple sensitive-point method

Multiple testing time points

Multiple-Point Fluorescent Detection

Multiple-point electrodes

Multiple-point failure

Multiple-point fault

Multiple-point grounding

Multiple-point kinetics

Multiple-point standardization

Point, critical solution multiple

Reactor point effectiveness multiple reactions

Versus multiple-point standardizations

© 2024 chempedia.info