Sources desorption

Matrix assisted laser desorption/ionization ion source desorption by photons proton transfer M+ < 1( 4 Pa ToF-MS, FTICR-MS tandem MS biomolecules... [Pg.72]

There are many other experiments in which surface atoms have been purposely moved, removed or chemically modified with a scanning probe tip. For example, atoms on a surface have been induced to move via interaction with the large electric field associated with an STM tip [78]. A scaiming force microscope has been used to create three-dimensional nanostructures by pushing adsorbed particles with the tip [79]. In addition, the electrons that are tunnelling from an STM tip to the sample can be used as sources of electrons for stimulated desorption [80]. The tuimelling electrons have also been used to promote dissociation of adsorbed O2 molecules on metal or semiconductor surfaces [81, 82]. [Pg.311]

A connnon feature of all mass spectrometers is the need to generate ions. Over the years a variety of ion sources have been developed. The physical chemistry and chemical physics communities have generally worked on gaseous and/or relatively volatile samples and thus have relied extensively on the two traditional ionization methods, electron ionization (El) and photoionization (PI). Other ionization sources, developed principally for analytical work, have recently started to be used in physical chemistry research. These include fast-atom bombardment (FAB), matrix-assisted laser desorption ionization (MALDI) and electrospray ionization (ES). [Pg.1329]

The main difference between field ionization (FI) and field desorption ionization (FD) lies in the manner in which the sample is examined. For FI, the substance under investigation is heated in a vacuum so as to volatilize it onto an ionization surface. In FD, the substance to be examined is placed directly onto the surface before ionization is implemented. FI is quite satisfactory for volatile, thermally stable compounds, but FD is needed for nonvolatile and/or thermally labile substances. Therefore, most FI sources are arranged to function also as FD sources, and the technique is known as FI/FD mass spectrometry. [Pg.23]

For nonvolatile or thermally labile samples, a solution of the substance to be examined is applied to the emitter electrode by means of a microsyringe outside the ion source. After evaporation of the solvent, the emitter is put into the ion source and the ionizing voltage is applied. By this means, thermally labile substances, such as peptides, sugars, nucleosides, and so on, can be examined easily and provide excellent molecular mass information. Although still FI, this last ionization is referred to specifically as field desorption (FD). A comparison of FI and FD spectra of D-glucose is shown in Figure 5.6. [Pg.26]

Sometimes, in FD, the emitter electrode is heated gently either directly by an electrode current or indirectly by a radiant heat source to aid desorption of ions from its surface. [Pg.27]

Until about the 1990s, visible light played little intrinsic part in the development of mainstream mass spectrometry for analysis, but, more recently, lasers have become very important as ionization and ablation sources, particularly for polar organic substances (matrix-assisted laser desorption ionization, MALDI) and intractable solids (isotope analysis), respectively. [Pg.119]

A further important property of the two instruments concerns the nature of any ion sources used with them. Magnetic-sector instruments work best with a continuous ion beam produced with an electron ionization or chemical ionization source. Sources that produce pulses of ions, such as with laser desorption or radioactive (Californium) sources, are not compatible with the need for a continuous beam. However, these pulsed sources are ideal for the TOF analyzer because, in such a system, ions of all m/z values must begin their flight to the ion detector at the same instant in... [Pg.157]

On the other hand, there are some ionization techniques that are very useful, particularly at very high mass, but produce ions only in pulses. For these sources, the ion extraction field can be left on continuously. Two prominent examples are Californium radionuclide and laser desorption ionization. In the former, nuclear disintegration occurs within a very short time frame to give a... [Pg.192]

There are two common occasions when rapid measurement is preferable. The first is with ionization sources using laser desorption or radionuclides. A pulse of ions is produced in a very short interval of time, often of the order of a few nanoseconds. If the mass spectrometer takes 1 sec to attempt to scan the range of ions produced, then clearly there will be no ions left by the time the scan has completed more than a few nanoseconds (ion traps excluded). If a point ion detector were to be used for this type of pulsed ionization, then after the beginning of the scan no more ions would reach the collector because there would not be any left The array collector overcomes this difficulty by detecting the ions produced all at the same instant. [Pg.209]

The ablated vapors constitute an aerosol that can be examined using a secondary ionization source. Thus, passing the aerosol into a plasma torch provides an excellent means of ionization, and by such methods isotope patterns or ratios are readily measurable from otherwise intractable materials such as bone or ceramics. If the sample examined is dissolved as a solid solution in a matrix, the rapid expansion of the matrix, often an organic acid, covolatilizes the entrained sample. Proton transfer from the matrix occurs to give protonated molecular ions of the sample. Normally thermally unstable, polar biomolecules such as proteins give good yields of protonated ions. This is the basis of matrix-assisted laser desorption ionization (MALDI). [Pg.399]

Ultrasound frequencies can be introduced into the walls of the vacuum system. If a source of ultrasound is placed on the wall of an ultrahigh vacuum system, a large hydrogen peak is observed. Related phenomena, presumably from frictional effects, are observed if the side of a vacuum system is tapped with a hammer a desorption peak can be seen. Mechanical scraping of one part on another also produces desorption. [Pg.376]

In COMIS, source or sink strength can be defined as time dependent but not dependent on actual concentrations or temperatures. COMTAM96 includes more sophisticated models such as chemical reactions, adsorption and desorption to building materials, filtration, and deposition to surfaces. [Pg.1087]

There are, however, numerous cases where electronegative additives can act as promoters for catalytic reactions. Typical examples are the use of Cl to enhance the selectivity of Ag epoxidation catalysts and the plethora of electrochemical promotion studies utilizing O2 as the promoting ion, surveyed in Chapters 4 and 8 of this book. The use of O, O8 or O2 as a promoter on metal catalyst surfaces is a new development which surfaced after the discovery of electrochemical promotion where a solid O2 conductor interfaced with the metal catalyst acts as a constant source of promoting O8 ions under the influence of an applied voltage. Without such a constant supply of O2 onto the catalyst surface, the promoting O8 species would soon be consumed via desorption or side reactions. This is why promotion with O2 was not possible in classical promotion, i.e. before the discovery of electrochemical promotion. [Pg.31]

Matrix-assisted laser desorption ionization post-source-decay mass spectrometry... [Pg.3]

Experimentation showed that the protein was not glycosylated and that the sequence at the iV-amino acid terminus corresponded to that expected. The C-terminus sequence, however, did not correspond to that predicted and these data were interpreted in terms of the presence of a heterogeneous, truncated, protein. A study of the tryptic digest fragments from this protein with matrix-assisted laser desorption ionization (MALDI) with post-source decay enabled the authors to suggest the positions at which the parent protein had been truncated. [Pg.199]

In order to prepare ZSM-5 zeolite nanocrystals, an A1 source of aluminium isopropoxide was added into solution A, and hydrothermal synthesis of the solution A containing Si and A1 sources was carried out in an 0-15/cyclohexane solution at 120 degree C for 50 h. Figures 4 show ac-NHj-TPD spectra and a SEM photograph of the ZSM-5 zeolite nanocrystals. Nanocrystals with a diameter of approximately 150 nm were observed, and the NH3-TPD spectrum showed desorption of NHj above 600 K, indicating that the nanocrystals possessed strong acid sites. [Pg.188]

The chemical compositions of the isolated Au SR clusters were investigated by mass spectrometry [15,16,18, 22,32-35]. TEM was used to confirm that the species detected by the mass spectrometer represents the clusters in the sample. Figure 3a is a schematic representation of the top view of the mass spectrometer, which consists of five stages of differentially pumped vacuum chambers. The apparatus accommodates two t5 pes of ion sources, electrospray ionization (ESI) and laser-desorption ionization (EDI), and a time-of-flight (TOE) mass spectrometer with a reflectron. Details of the apparatus and the measurement protocols are described below. [Pg.376]


See other pages where Sources desorption is mentioned: [Pg.937]    [Pg.937]    [Pg.934]    [Pg.1331]    [Pg.153]    [Pg.160]    [Pg.199]    [Pg.399]    [Pg.171]    [Pg.53]    [Pg.545]    [Pg.223]    [Pg.376]    [Pg.1881]    [Pg.2207]    [Pg.48]    [Pg.563]    [Pg.568]    [Pg.297]    [Pg.329]    [Pg.135]    [Pg.217]    [Pg.203]    [Pg.186]    [Pg.329]    [Pg.172]    [Pg.172]    [Pg.537]    [Pg.101]    [Pg.247]    [Pg.218]    [Pg.103]   