Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Solid phase extraction examples

Two examples from the analysis of water samples illustrate how a separation and preconcentration can be accomplished simultaneously. In the gas chromatographic analysis for organophosphorous pesticides in environmental waters, the analytes in a 1000-mL sample may be separated from their aqueous matrix by a solid-phase extraction using 15 mb of ethyl acetate. After the extraction, the analytes are present in the ethyl acetate at a concentration that is 67 times greater than that in... [Pg.223]

This publication provides several examples of the use of solid-phase extractions for separating analytes from their matrices. Some of the examples included are caffeine from coffee, polyaromatic hydrocarbons from water, parabens from cosmetics, chlorinated pesticides from water, and steroids from hydrocortisone creams. Extracted analytes maybe determined quantitatively by gas (GC) or liquid chromatography (LG). [Pg.226]

This sample preparation involved, firstly, an extraction and the elimination of the solid matrix by filtration and, secondly, a concentration procedure employing a solid phase extraction cartridge. The compounds of interest were separated solely by dispersive interactions with the reversed phase. In the example given, the corn meal was spiked with the aflatoxins. [Pg.217]

Another equally important consideration before development of a determinative or confirmatory method is an understanding of the chemical properties of the analyte. Such an understanding becomes the cornerstone of a successful method since the unique chemical properties of each analyte provide the basis for isolation and detection schemes. Table 1 lists some of the important chemical properties that could be considered. For example, knowing the or p/fb of an analyte could influence the choice of a liquid-liquid extraction scheme, solid-phase extraction (SPE) cartridge, mobile phase pH, or mass spectrometric ionization. Knowing the overall polarity of the analyte can be very helpful in the evaluation of an extraction or separation. Currently, computational methods are available to obtain an estimate of the logP... [Pg.301]

Fluorous ligands introduce an ease of purification in that the tagged phosphine ligand, the palladium catalyst complexed ligand, and the oxidized ligand can be completely removed by direct fluorous solid-phase separation (F-SPE) prior to product isolation. Similarly, an example of a fluorous palladium-catalyzed microwave-induced synthesis of aryl sulfides has been reported, whereby the product purification was aided by fluorous solid-phase extraction [91]. [Pg.355]

We have used accurate mass measurements obtained by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOFMS) to differentiate and profile saponins from M. truncatula roots. An example is provided (Fig.3.11) showing the MALDI-TOFMS spectra of a solid-phase extract of M truncatula root tissue. In this spectrum, we can identify multiple saponins. [Pg.49]

A recent review by Pichon and Haupt169 summarizes the progress in the area of utilization of MIPs for sample preparation purposes and cites several examples of solid phase extraction (MISPE) from biological matrices. The requirements and applications of MIPs are reviewed in a recent book170 and other literature.171-176... [Pg.56]

In our laboratories, a cycle time of 90 sec can be achieved with a dilution factor of 1 25 for a given sample concentration, allowing the purity and identity control of two and a half 384-well microtiter plates per day. The online dilution eliminated an external step in the workflow and reduced the risks of decomposition of samples in the solvent mixture (weakly acidic aqueous solvent) required for analysis. Mao et al.23 described an example in which parallel sample preparation reduced steps in the workflow. They described a 2-min cycle time for the analysis of nefazodone and its metabolites for pharmacokinetic studies. The cycle time included complete solid phase extraction of neat samples, chromatographic separation, and LC/MS/MS analysis. The method was fully validated and proved rugged for high-throughput analysis of more than 5000 human plasma samples. Many papers published about this topic describe different methods of sample preparation. Hyotylainen24 has written a recent review. [Pg.111]

Typical instrument set-ups for online sample preparation, for example, solid phase extraction and sample pre-concentration, require the control of a six-port valve with an additional special column and a second pump. Ideally, this system will be fully controlled by the data acquisition software (Figure 3.12 (A)). [Pg.112]

Unfortunately, the appeal of solid phase extractions on small scale fades as the scale increases due to the cost and inconvenience of using large amounts of fluorous silica gel. Here, modified techniques to reduce the tedium of repeated extractions are attractive. For example, Crich has recently introduced the minimally fluorous selenide C6Fi3CH2CH2C6H4SeH[171. This selenol is added in catalytic quantities to tin hydride reductions of reactive aryl and vinyl radicals. The high reducing capacity of the aryl selenide suppresses undesired reactions of product radicals without suppressing the reactions of the aryl and vinyl radicals themselves. After the reaction is complete, the selenol can be recovered by a modified continuous extraction procedure. [Pg.32]

Another example of nitrogen-based ligands can be found in a new family of ligands that were developed in solution through the use of solid-phase extractions (SPE) (Scheme 22) (49). In this approach, a building block strategy was taken in... [Pg.457]

An example of a solid-phase extraction (SPE) used as a cleanup procedure is given in Procedure 12.7 The column is conditioned by passing water and the... [Pg.264]

The synthesis of 6-hydroxy fluvastatin with M. rammaniana DSM 62752 gave high conversion (>95 %) in shake flask culture on 400 mL scale with 0.1 g L of fluvastatin as well as on 22 L scale in a Wave bioreactor-fed batch process at a final substrate concentration of 0.4 g L Instead of the partial purification by a second solid-phase extraction described above, 6-hydroxy fluvastatin can be obtained in high purity ( 95 %) by, for example, preparative medium-pressure liquid chromatography (MPLC) on RP18 silica gel. ... [Pg.365]


See other pages where Solid phase extraction examples is mentioned: [Pg.161]    [Pg.161]    [Pg.213]    [Pg.589]    [Pg.116]    [Pg.418]    [Pg.54]    [Pg.350]    [Pg.232]    [Pg.123]    [Pg.524]    [Pg.422]    [Pg.716]    [Pg.902]    [Pg.904]    [Pg.21]    [Pg.432]    [Pg.50]    [Pg.140]    [Pg.75]    [Pg.126]    [Pg.422]    [Pg.61]    [Pg.10]    [Pg.26]    [Pg.64]    [Pg.212]    [Pg.280]    [Pg.32]    [Pg.529]    [Pg.538]    [Pg.104]    [Pg.131]    [Pg.193]    [Pg.188]    [Pg.15]    [Pg.570]    [Pg.97]    [Pg.193]   
See also in sourсe #XX -- [ Pg.259 , Pg.260 , Pg.261 , Pg.262 , Pg.263 , Pg.264 , Pg.265 , Pg.266 ]




SEARCH



Extract phase

Extractants, examples

Extractives examples

Molecularly imprinted solid phase extraction examples

Phase extraction

© 2024 chempedia.info