Slide collection

Collection Techniques. The simplest mechanical method for normal liquid droplets is the slide collection slide sampling) or impression method. This method was extensively used three decades ago, and has been rarely employed since then. In this method, when the slide is exposed to a spray, droplets impinging on it make impressions. The impressions are then observed and measured usually using a Quantimet image analyzer, although a microscope fitted with a traversing scale may be used for the measurement. The measured data are subsequently converted to actual droplet sizes based on a correction factor proposed by May.[659]... [Pg.401]

The dustiness index of coal is a means of determining the relative values that represent the amount of dust produced when coal is handled in a standard manner. Thus, a 50-lb sample of coal is placed on a slide plate in a metal cabinet of prescribed size. When the plate is withdrawn, the sample falls into a drawer, and after 5 seconds, two slides are inserted into the box. The slides collect suspended dust particles for 2 minutes (coarse dust) or for 10 minutes (fine dust). The dustiness index is reported as 40 times the gram weight of dust that has settled after either 2 minutes or after an additional 8 minutes. [Pg.164]

Experimental Comparison with Other Techniques. In order to check that the experimental setup shown in Figure 3 met the constraints formulation given in Equation 2, two alternate techniques were used to measure droplet size during selected tests. These were a magnesium-oxide (MgO) coated slide collection method and a single-beam Mie scattering technique. [Pg.132]

Entomological Society of America/Ries Memorial Slide Collection p. 325, top left and center p. 334, top left. [Pg.497]

Tilted-Plate Clarifiers Lamella or tilted-plate separators have achieved increased use for clarification. They contain a multiplicity of plates inchned at 45 to 60° from the horizontal. Various feed methods are employed so that the influent passes into each inchned channel at about one-third of the vertical height from the bottom. This results in the solids having to settle only a short distance in each channel before sliding down the base to the collection zone beneath the plates. The clarified liquid passes in the opposite direction beneath the ceiling of each channel to the overflow connection. [Pg.1684]

Static sampling systems are defined as those that do not have an active air-moving component, such as the pump, to pull a sample to the collection medium. This type of sampling system has been used for over 100 years. Examples include the lead peroxide candle used to detect the presence of SO2 in the atmosphere and the dust-fall bucket and trays or slides coated with a viscous material used to detect particulate matter. This type of system suffers from inability to quantify the amount of pollutant present over a short period of time, i.e., less than 1 week. The potentially desirable characteristics of a static sampling system have led to further developments in this type of technology to provide quantitative information on pollutant concentrations over a fked period of time. Static sampling systems have been developed for use in the occupational environment and are also used to measure the exposure levels in the general community, e.g., radon gas in residences. [Pg.189]

Electrodes in the center of the flow lane are maintained at high voltage and generate the electrical field that forces the particles to the collector walls. In dry ESPs, the collectors are knocked, or "rapped," by various mechanical means to dislodge the particulate, which slides downward into a hopper where they are collected. [Pg.423]

Recently, dry wire-pipe ESPs are being cleaned acoustically with sonic horns (Flynn, 1999). The horns, typically cast metal horn bells, are usually powered by compressed air, and acoustic vibration is introduced by a vibrating metal plate that periodically interrupts the airflow (AWMA, 1992). As with a rapping system, the collected particulate slides downward into the hopper. The hopper is evacuated periodically, as it becomes full. Dust is removed through a valve into a dust-handling system, such as a pneumatic conveyor, and is then disposed of in an appropriate marmer. [Pg.423]

Bacteria Count The count of bacteria collected on a slide within a duct run or in a space. [Pg.1416]

PSD is an important indicator of the fluidization characteristics of the catalyst, cyclone performance, and the attrition resistance of the catalyst. A drop in fines content indicates the loss of cyclone efficiency. This can be confirmed by the particle size of fines collected downstream of the cyclones. An increase in fines content of the E-cat indicates increased catalyst attrition. This can be due to changes in fresh catalyst binder quality, steam leaks, and/or internal mechanical problems, such as those involving the air distributor or slide vah es. [Pg.107]

In order to investigate the friction properties of lubricant film in TFL, an apparatus with a floating device was developed by Shen et al. as shown in Fig. 17 [48]. The steel ball is fixed so that it does not roll in the experiment and a pure sliding has been kept. The measuring system of micro-friction force is composed of a straining force sensor with a resolution of 5 yu,N, a dynamic electric resistance strain gage, an AD data-collecting card, and a computer. [Pg.43]

Particles become positively charged by a corona discharge and travel out of the charging chamber and collect on a substrate such as a microscope slide. Thus, the method is useful for particles which are to be examined by optical or electron microscopy. [Pg.313]

Rotary sampling devices called Rotorods have also been widely used for sampling airborne sprays.These devices are similar to the rotary samplers described above, but do not use Teflon or magnesium oxide slides for spray collection. Rather, droplets... [Pg.979]

In order to validate sliding spark spectrometry results, plastic material was collected and the element concentration was determined via AAS after digestion. The samples were used as calibration standards. Additional standards were obtained by manufacturing known amounts of additives in the polymer matrix. Calibrations were made for Cd, Cr, Pb, Zn, Sb, Si and Ti in chlorine-free polymers Al, Ba, Ca, Cd, Pb, Sn, Ti, Zn in PVC chlorine (as PVC) and bromine in polyurethane (PUR). A calibration curve for Br as a flame retardant in PUR is shown in Figure 8.5. [Pg.617]

An example of the effects of waste settlement can be illustrated by a recent incident at a hazardous waste landfill facility in California.5 At this facility, waste settlement led to sliding of the waste, causing the standpipes (used to monitor secondary leachate collection sumps) to move 60-90 ft downslope in 1 day. Because there was a very low coefficient of friction between the primary liner and the geonet, the waste (which was deposited in a canyon) slid down the canyon. There was also a failure zone between the secondary liner and the clay. A two-dimensional slope stability analysis at the site indicated a factor of safety (FS) greater than 1. A three-dimensional slope stability analysis, however, showed that the safety factor had dropped below one. Three-dimensional slope stability analyses should therefore be considered with canyon and trench landfills. [Pg.1122]


See other pages where Slide collection is mentioned: [Pg.35]    [Pg.404]    [Pg.45]    [Pg.57]    [Pg.1672]    [Pg.349]    [Pg.267]    [Pg.24]    [Pg.35]    [Pg.404]    [Pg.45]    [Pg.57]    [Pg.1672]    [Pg.349]    [Pg.267]    [Pg.24]    [Pg.274]    [Pg.105]    [Pg.82]    [Pg.439]    [Pg.210]    [Pg.239]    [Pg.94]    [Pg.239]    [Pg.766]    [Pg.532]    [Pg.230]    [Pg.119]    [Pg.432]    [Pg.220]    [Pg.979]    [Pg.328]    [Pg.56]    [Pg.450]    [Pg.259]    [Pg.857]    [Pg.182]    [Pg.17]    [Pg.223]    [Pg.349]   
See also in sourсe #XX -- [ Pg.401 ]