Clarifiers tilted-plate

Tilted-Plate Clarifiers Lamella or tilted-plate separators have achieved increased use for clarification. They contain a multiplicity of plates inchned at 45 to 60° from the horizontal. Various feed methods are employed so that the influent passes into each inchned channel at about one-third of the vertical height from the bottom. This results in the solids having to settle only a short distance in each channel before sliding down the base to the collection zone beneath the plates. The clarified liquid passes in the opposite direction beneath the ceiling of each channel to the overflow connection. [Pg.1684]

The principal advantage of the tilted-plate clarifier is the increased capacity per unit of plane area. Major disadvantages are an underflow solids concentration that generally is lower than in other gravity clarifiers and difficulty of cleaning when scahng or deposition occurs. The lower underflow composition is due primarily to the reduced com-... [Pg.1684]

Figure 14 Schematic of a tilted-plate clarifier (Heil Process Equipment Co.). (From Schweitzer, 1997.)... Figure 14 Schematic of a tilted-plate clarifier (Heil Process Equipment Co.). (From Schweitzer, 1997.)...

See other pages where Clarifiers tilted-plate is mentioned: [Pg.1621]    [Pg.1442]    [Pg.1505]    [Pg.1625]    [Pg.1688]    [Pg.835]    [Pg.835]   