Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sensitivity adjusted analyses

We will say quite a bit later, in the chapter on adjusted analysis and analysis of covariance (Chapter 6) about additional improvements to this kind of analysis that increase sensitivity further and also avoid the so-called potential problem of regression towards the mean. For the moment though, it is test 3 that is the best way to compare the treatments. [Pg.63]

Sensitivity Sensitivity in flame atomic emission is strongly influenced by the temperature of the excitation source and the composition of the sample matrix. Normally, sensitivity is optimized by aspirating a standard solution and adjusting the flame s composition and the height from which emission is monitored until the emission intensity is maximized. Chemical interferences, when present, decrease the sensitivity of the analysis. With plasma emission, sensitivity is less influenced by the sample matrix. In some cases, for example, a plasma calibration curve prepared using standards in a matrix of distilled water can be used for samples with more complex matrices. [Pg.440]

A method suitable for analysis of sulfur dioxide in ambient air and sensitive to 0.003—5 ppm involves aspirating a measured air sample through a solution of potassium or sodium tetrachloromercurate, with the resultant formation of a dichlorosulfitomercurate. Ethylenediaminetetraacetic acid (EDTA) disodium salt is added to this solution to complex heavy metals which can interfere by oxidation of the sulfur dioxide. The sample is also treated with 0.6 wt % sulfamic acid to destroy any nitrite anions. Then the sample is treated with formaldehyde and specially purified acid-bleached rosaniline containing phosphoric acid to control pH. This reacts with the dichlorosulfitomercurate to form an intensely colored rosaniline—methanesulfonic acid. The pH of the solution is adjusted to 1.6 0.1 with phosphoric acid, and the absorbance is read spectrophotometricaHy at 548 nm (273). [Pg.147]

Once the model was complete, it was adjusted to a steady state condition and tested using historic carbon isotope data from the atmosphere, oceans and polar ice. Several important parameters were calculated and chosen at this stage. Sensitivity analysis indicated that results dispersal of the missing carbon - were significantly influenced by the size of the vegetation carbon pool, its assimilation rate, the concentration of preindustrial atmospheric carbon used, and the CO2 fertilization factor. The model was also sensitive to several factors related to fluxes between ocean reservoirs. [Pg.418]

The modeling of steady-state problems in combustion and heat and mass transfer can often be reduced to the solution of a system of ordinary or partial differential equations. In many of these systems the governing equations are highly nonlinear and one must employ numerical methods to obtain approximate solutions. The solutions of these problems can also depend upon one or more physical/chemical parameters. For example, the parameters may include the strain rate or the equivalence ratio in a counterflow premixed laminar flame (1-2). In some cases the combustion scientist is interested in knowing how the system mil behave if one or more of these parameters is varied. This information can be obtained by applying a first-order sensitivity analysis to the physical system (3). In other cases, the researcher may want to know how the system actually behaves as the parameters are adjusted. As an example, in the counterflow premixed laminar flame problem, a solution could be obtained for a specified value of the strain... [Pg.404]

Complex peptide mixmres can now be analyzed without prior purification by tandem mass spectrometry, which employs the equivalent of two mass spectrometers linked in series. The first spectrometer separates individual peptides based upon their differences in mass. By adjusting the field strength of the first magnet, a single peptide can be directed into the second mass spectrometer, where fragments are generated and their masses determined. As the sensitivity and versatility of mass spectrometry continue to increase, it is displacing Edman sequencers for the direct analysis of protein primary strucmre. [Pg.27]

Criteria 1) Relevance to human health endpoints. 2) Sensitivity to change in loadings. 3) Overall historical data quality. 4) Data collection infrastructure. 5) Feasibility of data collection and analysis. 6) Ability to adjust for confounding factors. 7) Understanding of linkages with rest of ecosystem. 8) Broad geographic distribution. 9) Well-known life history (for fauna). 10) Nonintrusive sampling. [Pg.198]

Where is the initial analyte concentration in the liquid phase, C( the concentration of analyte in the gas phase, K the gas-liquid partition coefficient for the analyte at the analysis temperature, V, the volume of liquid phase, and V, the volume of gas phase (318-321,324,325). From equation (8.3) it can be seen that the concentration of the analyte in the headspace above a liquid in equilibrium with a vapor phase will depend on the volume ratio of the geis and liquid phases and the compound-specific partition coefficient which, in turn, is matrix dependent. The sensitivity 1 of the headspace sampling method can be increased in some instances adjusting the pH, salting out or raising the... [Pg.923]

Electrospray has been successful for numerous azo dyes that are not ionic salts. Several anthraquinone dyes have been analysed by LC-ESI-MS [552]. Electrospray achieves the best sensitivity for compounds that are precharged in solution (e.g. ionic species or compounds that can be (de)protonated by pH adjustment). Consequently, LC-ESI-MS has focused on ionic dyes such as sulfonated azo dyes which have eluded analysis by particle-beam or thermospray LC-MS [594,617,618]. Techniques like LC-PB-MS and GC-MS, based on gas-phase ionisation, are not suitable for nonvolatile components such as sulfonated azo dyes. LC-TSP-MS on... [Pg.514]

It is recommended that the protocol itself contain language that allows for minor modifications of an analytical method or procedure without necessitating an amendment (or a deviation) for example, "Minor modifications in instrumental parameters and/or adjustments in technique may be made in the method during specimen analysis to enhance overall efficiency or the sensitivity, specificity, or selectivity of analyte response."... [Pg.157]

A special adaptation of this analysis was applied by Donachie (D8) to estimate the pipe resistances using field measurements of pressures. In that application the u s correspond to pipe resistances and the x s correspond to the nodal pressures. Using linearized sensitivity information adjustments of u s are made, one at a time, to reduce the discrepancies between calculated and measured pressures according to the least-squares criterion. The Am which causes the largest change in the sum of squares of discrepancies is given precedence over others. [Pg.174]

Table 5.8 gives an indication of the range of elements that may be determined. Most procedures will require an analyte concentration of 10-3 mol dm 3 or more, although with special conditions, notably potentiometric end-point detection, the sensitivity may be extended to 1(H mol dm 3. The analysis of mixtures of metal ions necessitates masking and demasking, pH adjustments and selective separation procedures. Areas of application are spread throughout the chemical field from water treatment and the analysis of refined food and petroleum products to the assay of minerals and alloys. Table 5.10 gives some selected examples. [Pg.213]

The analyses of trouble and the required counteractions will depend on the operation principles of the operator, the value of a lyophilizatiion charge, the sensitivity of the product on deviations from the set values, and several other factors. Nevertheless, an analysis of possible problems and a guideline for counteractions should be established for every freeze drying plant as part of the instruction manual, even if it has to be adjusted for new products. [Pg.171]


See other pages where Sensitivity adjusted analyses is mentioned: [Pg.287]    [Pg.110]    [Pg.617]    [Pg.324]    [Pg.24]    [Pg.138]    [Pg.194]    [Pg.676]    [Pg.295]    [Pg.389]    [Pg.398]    [Pg.422]    [Pg.578]    [Pg.314]    [Pg.384]    [Pg.350]    [Pg.262]    [Pg.766]    [Pg.265]    [Pg.586]    [Pg.664]    [Pg.253]    [Pg.50]    [Pg.133]    [Pg.992]    [Pg.211]    [Pg.434]    [Pg.619]    [Pg.94]    [Pg.294]    [Pg.261]    [Pg.124]    [Pg.307]    [Pg.959]    [Pg.367]    [Pg.236]    [Pg.245]   
See also in sourсe #XX -- [ Pg.97 , Pg.110 ]




SEARCH



Adjusted analysis

Sensitivity analysis

© 2024 chempedia.info