Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sampling matter

The simplest desolvation chambers consist simply of a tube heated to about 150°C through which the spray of droplets passes. During passage through this heated region, solvent evaporates rapidly from the droplets and forms vapor. The mixed vapor and residual small droplets or particulates of sample matter are swept by argon through a second cooled tube, which allows vapor to... [Pg.107]

Most of the methods described so far are immediately applicable to separated soil components however, in the analysis of a whole soil sample, matters are obvionsly more complicated because of the high number of components. There are several... [Pg.253]

The physics of X-ray refraction are analogous to the well known refraction of light by optical lenses and prisms, governed by Snell s law. The special feature is the deflection at very small angles of few minutes of arc, as the refractive index of X-rays in matter is nearly one. Due to the density differences at inner surfaces most of the incident X-rays are deflected [1]. As the scattered intensity of refraction is proportional to the specific surface of a sample, a reference standard gives a quantitative measure for analytical determinations. [Pg.558]

Since solids do not exist as truly infinite systems, there are issues related to their temiination (i.e. surfaces). However, in most cases, the existence of a surface does not strongly affect the properties of the crystal as a whole. The number of atoms in the interior of a cluster scale as the cube of the size of the specimen while the number of surface atoms scale as the square of the size of the specimen. For a sample of macroscopic size, the number of interior atoms vastly exceeds the number of atoms at the surface. On the other hand, there are interesting properties of the surface of condensed matter systems that have no analogue in atomic or molecular systems. For example, electronic states can exist that trap electrons at the interface between a solid and the vacuum [1]. [Pg.86]

In the previous sections we have described the interaction of the electromagnetic field with matter, that is, tlie way the material is affected by the presence of the field. But there is a second, reciprocal perspective the excitation of the material by the electromagnetic field generates a dipole (polarization) where none existed previously. Over a sample of finite size this dipole is macroscopic, and serves as a new source tenu in Maxwell s equations. For weak fields, the source tenu, P, is linear in the field strength. Thus,... [Pg.224]

The history of EM (for an overview see table Bl.17,1) can be interpreted as the development of two concepts the electron beam either illuminates a large area of tire sample ( flood-beam illumination , as in the typical transmission electron microscope (TEM) imaging using a spread-out beam) or just one point, i.e. focused to the smallest spot possible, which is then scaimed across the sample (scaiming transmission electron microscopy (STEM) or scaiming electron microscopy (SEM)). In both situations the electron beam is considered as a matter wave interacting with the sample and microscopy simply studies the interaction of the scattered electrons. [Pg.1624]

Time-resolved fluorescence is perhaps the most direct experunent in the ultrafast spectroscopist s palette. Because only one laser pulse interacts with the sample, the mediod is essentially free of the problems with field-matter time orderings that arise in all of the subsequently discussed multipulse methods. The signal... [Pg.1975]

Gr. technetos, artificial) Element 43 was predicted on the basis of the periodic table, and was erroneously reported as having been discovered in 1925, at which time it was named masurium. The element was actually discovered by Perrier and Segre in Italy in 1937. It was found in a sample of molybdenum, which was bombarded by deuterons in the Berkeley cyclotron, and which E. Eawrence sent to these investigators. Technetium was the first element to be produced artificially. Since its discovery, searches for the element in terrestrial material have been made. Finally in 1962, technetium-99 was isolated and identified in African pitchblende (a uranium rich ore) in extremely minute quantities as a spontaneous fission product of uranium-238 by B.T. Kenna and P.K. Kuroda. If it does exist, the concentration must be very small. Technetium has been found in the spectrum of S-, M-, and N-type stars, and its presence in stellar matter is leading to new theories of the production of heavy elements in the stars. [Pg.106]

An analysis, particularly a quantitative analysis, is usually performed on several replicate samples. How do we report the result for such an experiment when results for the replicates are scattered around a central value To complicate matters further, the analysis of each replicate usually requires multiple measurements that, themselves, are scattered around a central value. [Pg.70]

Equivalent Weights Acid-base titrations can be used to characterize the chemical and physical properties of matter. One simple example is the determination of the equivalent weighf of acids and bases. In this method, an accurately weighed sample of a pure acid or base is titrated to a well-defined equivalence point using a mono-protic strong acid or strong base. If we assume that the titration involves the transfer of n protons, then the moles of titrant needed to reach the equivalence point is given as... [Pg.309]

To examine a sample by inductively coupled plasma mass spectrometry (ICP/MS) or inductively coupled plasma atomic-emission spectroscopy (ICP/AES) the sample must be transported into the flame of a plasma torch. Once in the flame, sample molecules are literally ripped apart to form ions of their constituent elements. These fragmentation and ionization processes are described in Chapters 6 and 14. To introduce samples into the center of the (plasma) flame, they must be transported there as gases, as finely dispersed droplets of a solution, or as fine particulate matter. The various methods of sample introduction are described here in three parts — A, B, and C Chapters 15, 16, and 17 — to cover gases, solutions (liquids), and solids. Some types of sample inlets are multipurpose and can be used with gases and liquids or with liquids and solids, but others have been designed specifically for only one kind of analysis. However, the principles governing the operation of inlet systems fall into a small number of categories. This chapter discusses specifically substances that are normally liquids at ambient temperatures. This sort of inlet is the commonest in analytical work. [Pg.103]

The nebulization concept has been known for many years and is commonly used in hair and paint spays and similar devices. Greater control is needed to introduce a sample to an ICP instrument. For example, if the highest sensitivities of detection are to be maintained, most of the sample solution should enter the flame and not be lost beforehand. The range of droplet sizes should be as small as possible, preferably on the order of a few micrometers in diameter. Large droplets contain a lot of solvent that, if evaporated inside the plasma itself, leads to instability in the flame, with concomitant variations in instrument sensitivity. Sometimes the flame can even be snuffed out by the amount of solvent present because of interference with the basic mechanism of flame propagation. For these reasons, nebulizers for use in ICP mass spectrometry usually combine a means of desolvating the initial spray of droplets so that they shrink to a smaller, more uniform size or sometimes even into small particles of solid matter (particulates). [Pg.106]

Suffice it to say at this stage that the surfaces of most solids subjected to such laser heating will be heated rapidly to very high temperatures and will vaporize as a mix of gas, molten droplets, and small particulate matter. For ICP/MS, it is then only necessary to sweep the ablated aerosol into the plasma flame using a flow of argon gas this is the basis of an ablation cell. It is usual to include a TV monitor and small camera to view the sample and to help direct the laser beam to where it is needed on the surface of the sample. [Pg.112]

In operation, a spark source is normally first flushed with argon to remove loose particulate matter from any previous analysis. The argon flow is then reduced, and the cathode is preheated or conditioned with a short bum time (about 20 sec). The argon flow is then reduced once more, and the source is ran for sufficient time to build a signal from the sample. The spark is then stopped, and the process is repeated as many times as necessary to obtain a consistent series of analyses. The arc source operates continuously, and sample signal can be taken over long periods of time. [Pg.114]

Samples to be examined by inductively coupled plasma and mass spectrometry (ICP/MS) are commonly in the form of a solution that is transported into the plasma flame. The thermal mass of the flame is small, and ingress of excessive quantities of extraneous matter, such as solvent, would cool the flame and might even extinguish it. Even cooling the flame reduces its ionization efficiency, with concomitant effects on the accuracy and detection limits of the ICP/MS method. Consequently, it is necessary to remove as much solvent as possible which can be done by evaporation off-line or done on-line by spraying the solution as an aerosol into the plasma flame. [Pg.137]

The calculation shows how rapidly a droplet changes in diameter with time as it flows toward the plasma flame. At 40°C, a droplet loses 90% of its size within alxtut 1.5 sec, in which time the sweep gas has flowed only about 8 cm along the tube leading to the plasma flame. Typical desolvation chambers operate at 150°C and, at these temperatures, similar changes in diameter will be complete within a few milliseconds. The droplets of sample solution lose almost all of their solvent (dry out) to give only residual sample (solute) particulate matter before reaching the plasma flame. [Pg.138]

Some solid materials are very intractable to analysis by standard methods and cannot be easily vaporized or dissolved in common solvents. Glass, bone, dried paint, and archaeological samples are common examples. These materials would now be examined by laser ablation, a technique that produces an aerosol of particulate matter. The laser can be used in its defocused mode for surface profiling or in its focused mode for depth profiling. Interestingly, lasers can be used to vaporize even thermally labile materials through use of the matrix-assisted laser desorption ionization (MALDI) method variant. [Pg.280]

A liquid sample must be vaporized to a gas or, more likely, to a vapor consisting of an aerosol of gas, small droplets, and even small particles of solid matter. To be examined, the aerosol is mixed with argon gas to make up the needed flow of gas into the plasma and is then swept into the flame. [Pg.397]


See other pages where Sampling matter is mentioned: [Pg.99]    [Pg.417]    [Pg.9]    [Pg.313]    [Pg.1433]    [Pg.302]    [Pg.99]    [Pg.417]    [Pg.9]    [Pg.313]    [Pg.1433]    [Pg.302]    [Pg.1179]    [Pg.1179]    [Pg.1181]    [Pg.1249]    [Pg.1529]    [Pg.1751]    [Pg.1779]    [Pg.119]    [Pg.418]    [Pg.25]    [Pg.34]    [Pg.1135]    [Pg.1160]    [Pg.99]    [Pg.233]    [Pg.346]    [Pg.346]    [Pg.525]    [Pg.653]    [Pg.97]    [Pg.112]    [Pg.113]    [Pg.139]    [Pg.143]    [Pg.116]   
See also in sourсe #XX -- [ Pg.580 ]




SEARCH



Macroscopic samples, of matter

Particulate matter sample ports

Sample particulate matter

Sampling particulate matter

Sampling particulate organic matter from

Sampling suspended particulate matter

© 2024 chempedia.info