Sampling auger

Diying oven Balance Moisture cans S3rringe or pipette 2 mm sieve Soil sampling auger... [Pg.72]

The nature of atomic-deactivation processes is such that photoelectrons are accompanied by x-ray emission or by Auger electron emission. For the lighter elements and for the outer atomic shells of the medium and heavy elements, Auger-electron emission is the predominant mode by which an atom deactivates. Moreover, when using high-energy electrons rather than x-rays to bombard a sample. Auger-electron emission predominates. [Pg.425]

AES Auger electron spectroscopy After the ejection of an electron by absorption of a photon, an atom stays behind as an unstable Ion, which relaxes by filling the hole with an electron from a higher shell. The energy released by this transition Is taken up by another electron, the Auger electron, which leaves the sample with an element-specific kinetic energy. Surface composition, depth profiles... [Pg.1852]

The strong point of AES is that it provides a quick measurement of elements in the surface region of conducting samples. For elements having Auger electrons with energies hr the range of 100-300 eV where the mean free path of the electrons is close to its minimum, AES is considerably more surface sensitive than XPS. [Pg.1859]

A typical x-ray photoelectron spectmm consists of a plot of the iatensity of photoelectrons as a function of electron E or Ej A sample is shown ia Figure 8 for Ag (21). In this spectmm, discrete photoelectron responses from the cote and valence electron energy levels of the Ag atoms ate observed. These electrons ate superimposed on a significant background from the Bremsstrahlung radiation inherent ia n onm on ochrom a tic x-ray sources (see below) which produces an increa sing number of photoelectrons as decreases. Also observed ia the spectmm ate lines due to x-ray excited Auger electrons. [Pg.275]

Natural Deposits. Natural deposits, eg, minerals and fossil fuels, are located by drilling operations. An auger, eg, a screw or worm, is turned in the earth and pulled out, and material is scraped from the auger for analysis. Alternatively, samples can be taken by hoUow core drills which, when withdrawn, enclose a core of the earth that is representative of the strata through which the drill has passed. Such core samples are used in geological surveys for fossil fuels. As the drill drives deeper into the strata, each core is extracted and placed in a shallow box and coded so that a complete cross section of the geological strata can be reconstmcted. From this, the relative thickness of coal and mineral seams can be directly measured. [Pg.305]

Yes, in combination with ion-beam sputtering 300 A for Auger analysis, even less for imaging Yes, called Scanning Auger Microscopy, SAM Sample requirements Vacuum-compatible materials Main use Elemental composition of inorganic materials... [Pg.24]

The incoming electron beam interacts with the sample to produce a number of signals that are subsequently detectable and useful for analysis. They are X-ray emission, which can be detected either by Energy Dispersive Spectroscopy, EDS, or by Wavelength Dispersive Spectroscopy, WDS visible or UV emission, which is known as Cathodoluminescence, CL and Auger Electron Emission, which is the basis of Auger Electron Spectroscopy discussed in Chapter 5. Finally, the incoming... [Pg.117]

Auger electron spectroscopy (AES) is a technique used to identify the elemental composition, and in many cases, the chemical bonding of the atoms in the surface region of solid samples. It can be combined with ion-beam sputtering to remove material from the surface and to continue to monitor the composition and chemistry of the remaining surface as this surface moves into the sample. It uses an electron beam as a probe of the sample surface and its output is the energy distribution of the secondary electrons released by the probe beam from the sample, although only the Ai er electron component of the secondaries is used in the analysis. [Pg.310]

Auger electron spectroscopy is the most frequently used surface, thin-film, or interface compositional analysis technique. This is because of its very versatile combination of attributes. It has surface specificity—a sampling depth that varies... [Pg.310]

The complete description of the number of Auger electrons that are detected in the energy distribution of electrons coming from a surface under bombardment by a primary electron beam contains many factors. They can be separated into contributions from four basic processes, the creation of inner shell vacancies in atoms of the sample, the emission of electrons as a result of Auger processes resulting from these inner shell vacancies, the transport of those electrons out of the sample, and the detection and measurement of the energy distribution of the electrons coming from the sample. [Pg.313]

The inelastic collision process is characterized by an inelastic mean free path, which is the distance traveled after which only 1/e of the Auger electrons maintain their initial energy. This is very important because only the electrons that escape the sample with their characteristic Auger energy are usefrd in identifying the atoms in... [Pg.314]

The measured Auger signal is proportional to the number of atoms sampled. In the derivative mode of data acquisition this is frequently not the case, for example, if an inappropriate modulation voltage is used or if the line shape has... [Pg.316]

There are at least four kinds of information available from an Auger spectrum. The simplest and by far most frequently used is qualitative information, indicating which elements are present within the sampling volume of the measurement. Next there is quantitative information, which requires a little more care during acquisition to make it extractable, and a little more effort to extract it, but which tells how much of each of the elements is present. Third, there is chemical information which shows the chemical state in which these elements are present. Last, but by far the least used, there is information on the electronic structure of the material, such as the valance-band density of states that is folded into the line shape of transitions involving valance-band electrons. There are considerations to keep in mind in extracting each of these kinds of information. [Pg.317]


See other pages where Sampling auger is mentioned: [Pg.771]    [Pg.309]    [Pg.69]    [Pg.174]    [Pg.79]    [Pg.174]    [Pg.771]    [Pg.309]    [Pg.69]    [Pg.174]    [Pg.79]    [Pg.174]    [Pg.46]    [Pg.308]    [Pg.307]    [Pg.1713]    [Pg.1807]    [Pg.1828]    [Pg.1842]    [Pg.1858]    [Pg.1859]    [Pg.1859]    [Pg.198]    [Pg.317]    [Pg.318]    [Pg.277]    [Pg.356]    [Pg.286]    [Pg.306]    [Pg.19]    [Pg.24]    [Pg.73]    [Pg.119]    [Pg.231]    [Pg.280]    [Pg.311]    [Pg.311]    [Pg.312]    [Pg.314]    [Pg.315]    [Pg.319]    [Pg.320]   