Sample preparation improving techniques

The first studies using AFM as a detection tool for intra- or intermolecular force can only measure discrete force. As the techniques for tip and sample preparation improve, single-molecular... [Pg.158]

Theoretical and applied aspects of microwave heating, as well as the advantages of its application are discussed for the individual analytical processes and also for the sample preparation procedures. Special attention is paid to the various preconcentration techniques, in part, sorption and extraction. Improvement of microwave-assisted solution preconcentration is shown on the example of separation of noble metals from matrix components by complexing sorbents. Advantages of microwave-assisted extraction and principles of choice of appropriate solvent are considered for the extraction of organic contaminants from solutions and solid samples by alcohols and room-temperature ionic liquids (RTILs). [Pg.245]

Although SFE and SFC share several common features, including the use of a superaitical fluid as the solvent and similar instrumentation, their goals are quite distinct. While SFE is used mainly for the sample preparation step (extraction), SFC is employed to isolate (chr-omatography) individual compounds present in complex samples (11 -15). Both techniques can be used in two different approaches off-line, in which the analytes and the solvent are either vented after analysis (SFC) or collected (SFE), or on-line coupled with a second technique, thus providing a multidimensional approach. Off-line methods are slow and susceptible to solute losses and contamination the on-line coupled system makes possible a deaease in the detection limits, with an improvement in quantification, while the use of valves for automation results in faster and more reproducible analyses (16). The off-line... [Pg.137]

Analysis of methyl parathion in sediments, soils, foods, and plant and animal tissues poses problems with extraction from the sample matrix, cleanup of samples, and selective detection. Sediments and soils have been analyzed primarily by GC/ECD or GC/FPD. Food, plant, and animal tissues have been analyzed primarily by GC/thermionic detector or GC/FPD, the recommended methods of the Association of Official Analytical Chemists (AOAC). Various extraction and cleanup methods (AOAC 1984 Belisle and Swineford 1988 Capriel et al. 1986 Kadoum 1968) and separation and detection techniques (Alak and Vo-Dinh 1987 Betowski and Jones 1988 Clark et al. 1985 Gillespie and Walters 1986 Koen and Huber 1970 Stan 1989 Stan and Mrowetz 1983 Udaya and Nanda 1981) have been used in an attempt to simplify sample preparation and improve sensitivity, reliability, and selectivity. A detection limit in the low-ppb range and recoveries of 100% were achieved in soil and plant and animal tissue by Kadoum (1968). GC/ECD analysis following extraction, cleanup, and partitioning with a hexane-acetonitrile system was used. [Pg.181]

In addition to instrumental improvements, various approaches have been used to improve the purity or geometry of sources of natural samples for gamma spectrometric measurement. For example, improvements in source preparation for " Th measurement in water and sediment samples by gamma spectrometry are discussed in Cochran and Masque (2003). It should be emphasized that one of the main advantages of gamma spectrometry is ease of use, since in many cases samples may be analyzed directly or with significantly reduced sample preparation compared to alpha, beta, or mass spectrometric techniques. [Pg.31]

As scientists strive for ever lower detection limits, sample preparation techniques must inevitably continue to improve. Some future directions in sample preparation for chromatography can be delineated as follows ... [Pg.54]

Many of the classical techniques used in the preparation of samples for chromatography are labour-intensive, cumbersome, and prone to sample loss caused by multistep manual manipulations. During the past few years, miniaturisation has become a dominant trend in analytical chemistry. At the same time, work in GC and UPLC has focused on improved injection techniques and on increasing speed, sensitivity and efficiency. Separation times for both techniques are now measured in minutes. Miniaturised sample preparation techniques in combination with state-of-the-art analytical instrumentation result in faster analysis, higher sample throughput, lower solvent consumption, less manpower in sample preparation, while maintaining or even improving limits. [Pg.123]

Major advantages of LVI methods are higher sensitivity (compare the 100-1000 iL volume in LVI to the maximum injection volume of about 1 iL in conventional splitless or on-column injection), elimination of sample preparation steps (such as solvent evaporation) and use in hyphenated techniques (e.g. SPE-GC, LC-GC, GC-MS), which gives opportunities for greater automation, faster sample throughput, better data quality, improved quantitation, lower cost per analysis and fewer samples re-analysed. At-column is a very good reference technique for rapid LVI. Characteristics of LVI methods are summarised in Tables 4.19 and 4.20. Han-kemeier [100] has discussed automated sample preparation and LVI for GC with spectrometric detection. [Pg.191]

Principles and Characteristics Although early published methods using SPE for sample preparation avoided use of GC because of the reported lack of cleanliness of the extraction device, SPE-GC is now a mature technique. Off-line SPE-GC is well documented [62,63] but less attractive, mainly in terms of analyte detectability (only an aliquot of the extract is injected into the chromatograph), precision, miniaturisation and automation, and solvent consumption. The interface of SPE with GC consists of a transfer capillary introduced into a retention gap via an on-column injector. Automated SPE may be interfaced to GC-MS using a PTV injector for large-volume injection [64]. LVI actually is the basic and critical step in any SPE-to-GC transfer of analytes. Suitable solvents for LVI-GC include pentane, hexane, methyl- and ethylacetate, and diethyl or methyl-f-butyl ether. Large-volume PTV permits injection of some 100 iL of sample extract, a 100-fold increase compared to conventional GC injection. Consequently, detection limits can be improved by a factor of 100, without... [Pg.436]

Minimisation of sample preparation is the main bottleneck in polymer/additive analysis. The importance of sample preparation increases with miniaturisation of the separation techniques. However, there is no point in improving instrumentation when the true sources of errors in measurement are sampling, sample inhomogeneity or sample instability. [Pg.731]

Integration of sample preparation and chromatography by on-line coupling aims at reduction of analysis time. It is apparent from Section 7.1 that these hyphenated techniques are not yet contributing heavily to the overall efficiency of polymer/additive analysis in industry. On-line SFE-SFC requires considerable method development, and MAE-HPLC is off-line. Enhancement of sensitivity for trace analysis requires appropriate sample preparation and preconcentration schemes, as well as improved detection systems. [Pg.732]

It is generally difficult to identify developments with high potential where interferences do not preclude general application. To ensure the relevance of a method, its application to real sample analysis must be demonstrated. The accuracy of an analytical method should be confirmed by an independent method, or by the analysis of certified reference materials. Detailed comparative studies of the method developed with other well-established methods for polymer/additive analysis are not frequent in the analytical literature. Nevertheless, some examples may be found in Section 3.6. Improvements in analytical techniques are reasonably sought in sample preparation and in hyphenated chromatographic techniques. However, greatest efficiency is often gained from the use of databases rather than accelerated extraction or hyphenation. [Pg.744]

The introduction of high-resolution, high-efficiency /-ray detectors composed of lithium-drifted germanium crystals has revolutionised /-measurement techniques. Thus, /-spectrometry allows the rapid measurement of relatively low-activity samples without complex analytical preparations. A technique described by Michel et al. [25] uses Ge(Li) /-ray detectors for the simultaneous measurements of 228radium and 226radium in natural waters. This method simplifies the analytical procedures and reduces the labour while improving the precision, accuracy, and detection limits. [Pg.347]


See other pages where Sample preparation improving techniques is mentioned: [Pg.82]    [Pg.171]    [Pg.753]    [Pg.190]    [Pg.242]    [Pg.265]    [Pg.74]    [Pg.181]    [Pg.307]    [Pg.422]    [Pg.693]    [Pg.784]    [Pg.832]    [Pg.25]    [Pg.51]    [Pg.135]    [Pg.194]    [Pg.438]    [Pg.555]    [Pg.727]    [Pg.742]    [Pg.66]    [Pg.276]    [Pg.222]    [Pg.236]    [Pg.168]    [Pg.184]    [Pg.266]    [Pg.272]    [Pg.284]    [Pg.291]    [Pg.83]    [Pg.392]    [Pg.781]    [Pg.794]    [Pg.66]    [Pg.266]   
See also in sourсe #XX -- [ Pg.628 ]




SEARCH



Preparation techniques

Preparative techniques

Sample preparations improvements

Sampling techniques

Sampling techniques samples

© 2024 chempedia.info