Retention-time method

Tse et al. (1992) have reported a gas chromatographic retention time method which is simple and rapid for estimating of Henry s law constants. [Pg.94]

Direct determination of the column saturation capacity requires measurement of the adsorption isotherm. Use of methods such as frontal analysis, elution by characteristic point are classical techniques. Frontal analysis and elution by characteri.stic point require mg or gram quantities of pure product component. It is also possible to estimate the column saturation capacity from single-component overloaded elution profiles using the retention time method or using an iterative numerical method from a binary mixture [66J. [Pg.242]

From a practical point of view, it is likely to be sufficient to estimate the column saturation capacity using the retention time method from several single-component overloaded elution profiles. Part of the purpose of the screening tests is also to determine the impact of the column saturation capacity of the product for different mobile-phase systems, temperatures and packing media. Since the optimum amount loaded is a stronger function of the separation factor than the column saturation capacity, estimation of the column saturation factor over an exact measurement may be sufficient. It is likely to be sufficient to use only the product species saturation capacity as measures of the... [Pg.242]

A possibility to reduce the influence of column efficiency on the results obtained by the ECP method is to detect the position of the peak maximum only, which is called the peak-maximum or retention-time method. Graphs like Fig. 6.23 are then achieved by a series of pulse injections with different sample concentrations. The concentration and position of the maximum is strongly influenced by the adsorption equilibrium due to the compressive nature of either the front or the rear of the peak (Chapter 2.2.3). Thus, the obtained values are less sensitive to kinetic effects than in the case of the ECP method. The isotherm parameters can be evaluated in the same way as described in Section 6.5.7.6, but the same limitations have to be kept in mind. For some isotherm equations, analytical solutions of the ideal model can be used to replace the concentration at the maximum (Golshan-Shirazi and Guiochon, 1989 and Guiochon et al., 1994b). Thus, only retention times must be considered and detector calibration can be omitted in these cases. [Pg.285]

The primary use of isotherm data measurements carried out on single-component elution profiles or breakthrough curves is the determination of the single-component adsorption isotherms. This could also be done directly, by conventional static methods. However, these methods are slow and less accurate than chromatographic methods, which, for these reasons, have become very popular. Five direct chromatographic methods are available for this purpose frontal analysis (FA) [132,133], frontal analysis by characteristic point (FACP) [134], elution by characteristic point (ECP) [134,135], pulse methods e.g., elution on a plateau or step and pulse method) [136], and the retention time method (RTM) [137]. [Pg.122]

It is important to realize that many important processes, such as retention times in a given chromatographic column, are not just a simple aspect of a molecule. These are actually statistical averages of all possible interactions of that molecule and another. These sorts of processes can only be modeled on a molecular level by obtaining many results and then using a statistical distribution of those results. In some cases, group additivities or QSPR methods may be substituted. [Pg.110]

With conventional nonspectroscopic detectors, other methods must be used to identify the solutes. One approach is to spike the sample by adding an aliquot of a suspected analyte and looking for an increase in peak height. Retention times also can be compared with values measured for standards, provided that the operating conditions are identical. Because of the difficulty of exactly matching such conditions, tables of retention times are of limited utility. [Pg.575]

Thus far all the separations we have considered involve a mobile phase and a stationary phase. Separation of a complex mixture of analytes occurs because each analyte has a different ability to partition between the two phases. An analyte whose distribution ratio favors the stationary phase is retained on the column for a longer time, thereby eluting with a longer retention time. Although the methods described in the preceding sections involve different types of stationary and mobile phases, all are forms of chromatography. [Pg.597]

Continuing calibration for a Series Method is performed using calibration check compounds. Surrogate compounds are added to the matrix before sample preparation to evaluate recovery levels. To check GC retention times, internal standards are added to a sample after its preparation for analysis. [Pg.418]

The two procedures primarily used for continuous nitration are the semicontinuous method developed by Bofors-Nobel Chematur of Sweden and the continuous method of Hercules Powder Co. in the United States. The latter process, which uses a multiple cascade system for nitration and a continuous wringing operation, increases safety, reduces the personnel involved, provides a substantial reduction in pollutants, and increases the uniformity of the product. The cellulose is automatically and continuously fed into the first of a series of pots at a controlled rate. It falls into the slurry of acid and nitrocellulose and is submerged immediately by a turbine-type agitator. The acid is deflvered to the pots from tanks at a rate controlled by appropriate instmmentation based on the desired acid to cellulose ratio. The slurry flows successively by gravity from the first to the last of the nitration vessels through under- and overflow weirs to ensure adequate retention time during nitration. The overflow from the last pot is fully nitrated cellulose. [Pg.14]

Quantitative mass spectrometry, also used for pharmaceutical appHcations, involves the use of isotopicaHy labeled internal standards for method calibration and the calculation of percent recoveries (9). Maximum sensitivity is obtained when the mass spectrometer is set to monitor only a few ions, which are characteristic of the target compounds to be quantified, a procedure known as the selected ion monitoring mode (sim). When chlorinated species are to be detected, then two ions from the isotopic envelope can be monitored, and confirmation of the target compound can be based not only on the gc retention time and the mass, but on the ratio of the two ion abundances being close to the theoretically expected value. The spectrometer cycles through the ions in the shortest possible time. This avoids compromising the chromatographic resolution of the gc, because even after extraction the sample contains many compounds in addition to the analyte. To increase sensitivity, some methods use sample concentration techniques. [Pg.548]

The method was validated in accordance to the guidelines of the international conference on harmonization (ICH). Data with respect to accuracy, within- and between run precision, recovery, detection and quantitation limits were reported and found to be within the accepted international criteria. Neither endogeneous substances nor the commonly used dmgs were found to interfere with the retention times of the analytes. Standard solutions of the dmg and quality control preparations at high and low level concentrations were demonstrated to be stable at room temperature and/or -20°C for long and short periods of time. [Pg.395]

There is an interesting consequence to the above discussion on composite peak envelopes. If the actual retention times of a pair of solutes are accurately known, then the measured retention time of the composite peak will be related to the relative quantities of each solute present. Consequently, an assay of the two components could be obtained from accurate retention measurements only. This method of analysis was shown to be feasible and practical by Scott and Reese [1]. Consider two solutes that are eluted so close together that a single composite peak is produced. From the Plate Theory, using the Gaussian form of the elution curve, the concentration profile of such a peak can be described by the following equation ... [Pg.171]

Using equation (10), the efficiency of any solute peak can be calculated for any column from measurements taken directly from the chromatogram (or, if a computer system is used, from the respective retention times stored on disk). The computer will need to have special software available to identify the peak width and calculate the column efficiency and this software will be in addition to that used for quantitative measurements. Most contemporary computer data acquisition and processing systems contain such software in addition to other chromatography programs. The measurement of column efficiency is a common method for monitoring the quality of the column during use. [Pg.181]

You will also need a means of determining when the retention time has expired so that if necessary you can dispose of the records. The retention time doesn t mean that you must dispose of the records when the time expires - only that you must retain the records for at least that stated period. Records will need to be dated, the files that contain the records dated, and, if stored in an archive, the shelves or drawers dated. It is for this reason that all documents should carry a date of origin and this requirement needs to be specified in the procedures that describe the records. If you can rely on the selection process, a simple method is to store the records in bins or on computer disks that carry the date of disposal. [Pg.502]

Considering the numerous applications, heart-cut LC-LC has convincingly proven its value. Nevertheless, in LC-LC specific method development is generally needed for each analyte. Moreover, heart-cut procedures require accurate timing and, therefore, the performance of the first analytical column in particular should be highly stable to thus yield reproducible retention times. This often means that in LC-LC some kind of sample preparation remains necessary (see Table 11.1) in order to protect the first column from proteins and particulate matter, and to guarantee its lifetime. [Pg.265]


See other pages where Retention-time method is mentioned: [Pg.14]    [Pg.238]    [Pg.67]    [Pg.130]    [Pg.229]    [Pg.871]    [Pg.73]    [Pg.14]    [Pg.238]    [Pg.67]    [Pg.130]    [Pg.229]    [Pg.871]    [Pg.73]    [Pg.327]    [Pg.253]    [Pg.261]    [Pg.70]    [Pg.168]    [Pg.221]    [Pg.46]    [Pg.220]    [Pg.417]    [Pg.429]    [Pg.1219]    [Pg.1219]    [Pg.1318]    [Pg.1737]    [Pg.447]    [Pg.36]    [Pg.144]    [Pg.96]    [Pg.413]    [Pg.62]    [Pg.63]    [Pg.125]    [Pg.201]    [Pg.305]    [Pg.346]   