Reproducibility improvement analysis

One might speculate that the next real breakthrough in dynamic adsorption studies will come through improved measurement techniques. Once devices for accurate and reproducible response analysis are perfected, the identification and definitive classification of simultaneous adsorption phenomena as to kind, as to relative magnitude, and as to their characteristic rate constants can be realized. [Pg.282]

Analyses are types of calculations but may be comparative studies, predictions, and estimations. Examples are stress analysis, reliability analysis, hazard analysis. Analyses are often performed to detect whether the design has any inherent modes of failure and to predict the probability of occurrence. The analyses assist in design improvement and the prevention of failure, hazard, deterioration, and other adverse conditions. Analyses may need to be conducted as the end-use conditions may not be reproducible in the factory. Assumptions may need to be made about the interfaces, the environment, the actions of users, etc. and analysis of such conditions assists in determining characteristics as well as verifying the inherent characteristics. (See also in Part 2 Chapter 14 under Detecting design weaknesses.)... [Pg.253]

Although SFE and SFC share several common features, including the use of a superaitical fluid as the solvent and similar instrumentation, their goals are quite distinct. While SFE is used mainly for the sample preparation step (extraction), SFC is employed to isolate (chr-omatography) individual compounds present in complex samples (11 -15). Both techniques can be used in two different approaches off-line, in which the analytes and the solvent are either vented after analysis (SFC) or collected (SFE), or on-line coupled with a second technique, thus providing a multidimensional approach. Off-line methods are slow and susceptible to solute losses and contamination the on-line coupled system makes possible a deaease in the detection limits, with an improvement in quantification, while the use of valves for automation results in faster and more reproducible analyses (16). The off-line... [Pg.137]

Method validation is needed to demonstrate the acceptability of the analytical method. A recovery test on a chemical being determined should be performed in order to verify the reliability of the series of analyses. Recovery studies are usually conducted by spiking untreated sediment with the target chemical at the deteetion limit, quantitation limit and in the range of 10-50 times the detection limit. The method is considered acceptable when the recoveries typically are greater than 70%. When the recovery is less than 70%, an improvement in the analytical methods is needed. Where this is not possible for technical reasons, then lower recovery levels may be acceptable provided that method validation has demonstrated that reproducible recoveries are obtained at a lower level of recovery. Analysis is usually done in duplicate or more, and the coefficient of variation (CV) should be less than 10% to ensure that recoveries will be consistently within the range 70-110%. [Pg.904]

High performance capillary electrophoresis in its current form is a new technique. Its feasibility has been proven by the analysis and separation of small ions, drugs, chiral molecules, polymers, and biopolymers.93 We are learning more every day about the small tricks of the trade of the technique, and the efficiency and reproducibility of the methods are improving. [Pg.403]

Currently, LC-MS is widely used for the analysis of polar compounds, such as medicinal metabolites and bioactive peptides, since the interface has been improved and several new ionization methods have been developed. The sensitivity and reproducibility are sufficient for a daily quantitative analysis. The usefulness of the LC-MS has been demonstrated for studies on Type II pheromones using a time-of-flight MS with electrospray ionization (ESI) [180]. Each epoxydiene derived from the (Z3,Z6,Z9)-triene shows three ion series of [M+NHJ+, [M+H]+, and [M-OH]+ with high resolution and good sensitivity, indicating its molecular formula. In addition to these, characteristic fragment... [Pg.88]


See other pages where Reproducibility improvement analysis is mentioned: [Pg.1879]    [Pg.103]    [Pg.220]    [Pg.190]    [Pg.70]    [Pg.1116]    [Pg.104]    [Pg.359]    [Pg.756]    [Pg.792]    [Pg.70]    [Pg.103]    [Pg.321]    [Pg.904]    [Pg.384]    [Pg.5]    [Pg.55]    [Pg.290]    [Pg.241]    [Pg.40]    [Pg.47]    [Pg.34]    [Pg.131]    [Pg.428]    [Pg.13]    [Pg.127]    [Pg.187]    [Pg.233]    [Pg.236]    [Pg.275]    [Pg.203]    [Pg.106]    [Pg.33]    [Pg.32]    [Pg.193]    [Pg.205]    [Pg.327]    [Pg.67]    [Pg.223]    [Pg.113]    [Pg.12]    [Pg.306]    [Pg.17]   
See also in sourсe #XX -- [ Pg.354 , Pg.355 ]

See also in sourсe #XX -- [ Pg.354 , Pg.355 ]