Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Re-analyses

Major advantages of LVI methods are higher sensitivity (compare the 100-1000 iL volume in LVI to the maximum injection volume of about 1 iL in conventional splitless or on-column injection), elimination of sample preparation steps (such as solvent evaporation) and use in hyphenated techniques (e.g. SPE-GC, LC-GC, GC-MS), which gives opportunities for greater automation, faster sample throughput, better data quality, improved quantitation, lower cost per analysis and fewer samples re-analysed. At-column is a very good reference technique for rapid LVI. Characteristics of LVI methods are summarised in Tables 4.19 and 4.20. Han-kemeier [100] has discussed automated sample preparation and LVI for GC with spectrometric detection. [Pg.191]

In all three methods a blank is obtained. To ascertain the blank, excess sodium thiosulfate is added to the potassium iodide reagent at a concentration of 4.0 x 10 14 mol/1. Samples were re-analysed and the appropriate blank subtracted from the sample signal. [Pg.79]

It is pointless carrying out the analysis unless the results obtained are known to be meaningful. This can only be ensured by proper validation of the method before use and subsequent monitoring of its performance. The analysis of validated standards is the most satisfactory approach. Validated standards have been extensively analysed by a variety of methods, and an accepted value for the appropriate analyte obtained. A standard should be selected with a matrix similar to that of the sample. In order to ensure continued accurate analysis, standards must be re-analysed at regular intervals. [Pg.615]

We do not design our own algorithm here but use the fin Insearch. m function supplied by Matlab. It is based on the original Nelder, Mead simplex algorithm. As an example, we re-analyse our exponential decay data Data Decay. m (see p. 106], this time fitting both parameters, the rate constant and the amplitude. Compare the results with those from the linearisation of the exponential curve, followed by a linear least-squares fit, as performed in Linearisation of Non-Linear Problems, (p.127). [Pg.205]

As the second example, we re-analyse the consecutive reaction A— Data ABC. m, where data were acquired at many wavelengths. [Pg.206]

In the first example we re-analyse the double Gaussian from Data Chrom. m (p.158). [Pg.207]

In the next example, we re-analyse the consecutive reaction, Data ABC, m [p. 143)and [p.165], This time however, we use fewer data in order to keep the Excel spreadsheet reasonably compact. The important concept of treating linear and non-linear parameters separately can be implemented in Excel as well. [Pg.209]

The basic results from the individual units are processed and then combined to form the final result which is produced on the report printer. Results that deviate from an expected value by more than a preset tolerance may be marked or commented on. Additional information, such as sample identification and origin, is also made available. To ensure complete control by the analyst, the basic raw results may also be recorded in analogue form. Sample identification is provided so that the data can be re-analysed. Fully automatic systems require careful monitoring of the supply of reagents and the disposal of waste chemicals. To achieve this, fluid levels are monitored, and if they are low, an alarm signal is issued to the operator. [Pg.43]

The data from the BTO study mentioned above has been re-analysed more recently in connection with data from a Danish study (Chamberlain 1996 Fuller 1997). It concludes that the benefits derived from organic farming systems are whole system benefits and greater than those gained from higher levels of non-cropped areas alone. [Pg.27]

In the US the FDA request within the submission an electronic version of the database and this gives them the opportunity to not only re-analyse the data to confirm the results presented within the submission, but also to perform their own alternative analyses. This does not happen in Europe. In the US, therefore, the process following submission is somewhat different and much of the interchange in terms of requesting and supplying alternative analyses is taken care of by the FDA statisticians. [Pg.257]

If the measured concentration is far removed from the reference range, the original sample should be accordingly diluted and re-analysed. [Pg.110]

For these methods reference may be made to the following publications Pos-setto La chimica del vino M. A. Gautier La Sophistication des vins Ch. Girard et Sangle-Ferri re Analyse des matures alimeniaires J. Bellier Ann. de chim. analyl., 1900, p. 407. [Pg.202]

Examining a defatted extract of roasted coffee showed that it could similarly be separated into three fractions on Sephadex G25-fine. When the middle fraction was collected, freeze-dried, roasted at 200 °C for 3 min, and re-analysed, most of it had been converted into the fast-running high-MM peak, thus demonstrating that low-molecular-mass (LMM) melanoidins act as precursors to high-molecular-mass (HMM) ones.83... [Pg.24]

Volume-weighted averages are the amount of a given species deposited per unit area throughout the experiment divided by the amount of water deposited per unit area throughout the experiment. The prompt and delayed sulfate data are, respectively, the field-laboratory results and the re-analyses 7 months later. [Pg.37]

Bearing in mind the recent matrix IR assignment of = 202.2 cm-1, the vibrational structure of the electronic transition observed by Asundi et al.89 should be re-analysed a better resolved emission spectrum is also desirable. [Pg.24]

Technically, the transfer of the information from the ACTM to meteorological model is straightforward. For the operational forecasts, the next cycle meteorological calculations can use the previous cycle chemical composition results. For the case of nested simulations, both re-analyses and forecasts, the next-step nested meteorological computations can utilise the previous-step composition data. [Pg.165]

The Atmospheric Chemistry-Aerosol-Transport models/modules depend on applicable meteorological driver as well as selected domain of interest and hence, different meteorological operational or re-analysed archived datasets from NWP (such as DMI-HIRLAM (Unden et al. 2002 Sass et al. 2002) or ECMWF) models (or climate models) can be used. At present, output from several nested versions of DMl-HlRLAM is applied (Fig. 16.2) ... [Pg.169]

The best fractions of the main peak from three autoprep runs were then bulked and returned to the chemist for recovery. This sample was then re-analysed to test the purity of the resultant material. Fig. 8.10 shows the chromatograms and integration reports of the original crude compound and of the main component after the autoprep clean-up. As can be seen, the measured purity of the sample rose from 61.6% before the autoprep purification, to 96.7% afterwards. [Pg.322]

In contrast, peridotites metasomatized by small melt fractions show enrichment in platinum and palladium and elevated (Pd/Ir) . Bulk mineral separate PGE-Re analyses of two fertile xenoliths from southeastern Australia indicate less than 6% of the whole-rock PGE budget resides in either silicate or oxide phases and further implicates sulfides and alloys as the main controls of PGE-Re abundance. Comparison of sulfide versus whole-rock budgets by Lorand and Alard (2001) demonstrates the dominance of sulfide as the main PGE host in relatively fertile peridotites. This confirms the results of earlier studies of xenolith PGE mass balance (Hart and Ravizza, 1996 Mitchell and Keays, 1981) plus xenolith-derived and diamond inclusion sulfide studies (Jagoutz et al, 1979 Pearson et al, 1998b). As with cratonic xenoliths, sulfur-PGE and major-element-PGE correlations in more depleted noncratonic peridotites indicate that I-PGEs are probably not hosted entirely by sulfide (Lee, 2002). [Pg.910]

This topic has been re-analysed in a systematic review of published papers, in which relevant information from a total of 34 patients was identified (163). AU but two patients were also taking concomitant drugs known to affect the muscles, among which glucocorticoids, simvastatin, lovastatin, colchicine, and pyrazinamide were the most frequently cited. Ciclosporin is therefore difficult to implicate in most patients, but at least one case with positive ciclosporin re-administration supported a causative role. The clinical picture was non-specific, with myalgia, cramps, and muscle weakness, sometimes associated with raised serum creatine kinase activity, and heterogeneous histopathology. FinaUy, skeletal muscle abnormalities have rarely been described in patients without muscle symptoms. [Pg.753]

Safety data relating to the use of cilostazol in 2702 patients who participated in eight USA-UK placebo-controlled trials have been re-analysed (8). The most frequently recorded adverse events were headache (32%), diarrhea (17%), and abnormal stools (14%). [Pg.773]

It is interesting that the p(4xl), p(9xl), and p(5xl) atomic stmctures determined from the STM images all disagree with stmctures based on earlier LEED, x-ray scattering and TEAS studies. In the earlier studies all p(nxl) stmctures were believed to be overlayer stmctures, whereas the STM images provide convincing evidence that the Pb is substitutes into the Cu substrate. In the case of the p(5xl) stmcture, Nagl et al. [21] re-analysed the earlier x-ray diffraction study of Marra et al. [93] and found that it is possible to reconcile the... [Pg.173]


See other pages where Re-analyses is mentioned: [Pg.637]    [Pg.215]    [Pg.36]    [Pg.56]    [Pg.328]    [Pg.21]    [Pg.28]    [Pg.28]    [Pg.55]    [Pg.350]    [Pg.351]    [Pg.233]    [Pg.257]    [Pg.87]    [Pg.86]    [Pg.77]    [Pg.135]    [Pg.282]    [Pg.447]    [Pg.969]    [Pg.254]    [Pg.242]    [Pg.315]    [Pg.320]    [Pg.340]    [Pg.587]   
See also in sourсe #XX -- [ Pg.257 ]




SEARCH



Failed Runs and Re-Analysis

Incurred sample re-analysis

© 2024 chempedia.info